• Title/Summary/Keyword: 초저온도

Search Result 59, Processing Time 0.023 seconds

A Study of Mechanical Properties for Austenite Stainless Steel of Cryogenic Liquied Nitrogen Storage Tank (초저온 액화질소 저장용기의 오스테나이트계 스테인리스강의 기계적 특성 연구)

  • Choi, Dong-Jun;Park, Hyung-Wook;Cho, Jong-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.451-459
    • /
    • 2011
  • Austenitic stainless steels of 300 series are widely used as the structural material due to excellent their cryogenic mechanical properties at cryogenic temperature. There are 316 steel which molybdenum is added to improve the austenitic stability, 316L which carbon contents is reduced to decrease the grain boundary precipitation during welding process, and 316LN which nitrogen is added to improve the austenitic stability and the mechanical strength. But material researches for the welding conditions and mechanical properties at the cryogenic temperature were insufficient so far. In this paper, the characteristics of mechanical properties considering the effect of welding conditions and cryogenic temperature are studied.

Whole-body Management System using Ultra-Low Temperature Cyclical Cooling Method Combined with IT Technology (IT 기술을 접목한 초저온 순환 냉각 방식의 전신 관리 시스템)

  • Kim, Joo-Ho;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.673-676
    • /
    • 2020
  • In this paper, we propose a whole-body management system using ultra-low temperature cyclical cooling method combined with IT technology. The proposed system has the following characteristics. First, it minimizes maintenance costs by circulating nitrogen gas cooled by ultra-low temperature inside the controller. Secondly, based on the information measured by the temperature sensor and oxygen concentration sensor, nitrogen gas is supplied to provide safe ultra-low temperature whole-body management. Thirdly, after entering the user's height, it provides convenient, ultra-low temperature whole-body care that can be controlled using an automatic lift. Fourth, it provides an easy-to-access, easy-to-manage GUI and a manager-only web program for whole-body management system operation. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of ±5%, the world's highest temperature sensor accuracy, and a range of -110℃ to -150℃ greater than the world's highest whole-body management temperature range(-110℃ ~ -140℃). In addition, humidity was measured at less than 40%, the world's highest, and oxygen concentration was more than 18%, the world's highest. Therefore, the effectiveness of the methods proposed in this paper was demonstrated because they produced the same results as the world's highest levels.

Characteristics of Evaporation Heat Transfer in a Small-Scale Cryogenic Heat Exchange System for the Utilization of LNG Cold Energy (LNG 냉열활용을 위한 초저온 열교환시스템의 축소모형에서 증발 열전달 특성)

  • Nam S. C.;Lee S. C.;Lee Y. W.;Sohn Y. S.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.25-33
    • /
    • 1998
  • The characteristics of evaporation heat transfer for the utilization of LNG cold energy was investigated experimentally using liquified nitrogen and a solution of ethylene-glycol and water under horizontal two-phase conditions in the small-scale equipment of a cryogenic heat exchange system. The inner tubes in the double pipe heat exchanger with 8 mm and 15 mm inner diameter and 6 m length were adopted as a smooth test tubes and enhanced tubes by means of wire-coil inserts. Heat transfer coefficients and Nusselt number for the test tube were calculated from measurements of temperatures, flowrates and pressures. The correlations in a power-law relationship of the Nusselt number, the Reynolds number and Prandtl number for heat transfer were proposed which can be available for design of cryogenic heat exchangers. The correlations showed heat transfer coefficients for the wire-coil inserts were much higher than those for the smooth tubes, increased by more than 2.5 ${\~}$ 5.5 times depending upon the equivalent Reynolds number. Form and length of cryogenic double pipe heat exchanger were proposed for applicable to the utilization of LNG cold energy.

  • PDF

A Study of Characteristics Change of Low-Shrinkage Normal Strength Concrete According to Mixing Factors and curing Temperature (배합요인과 양생온도에 따른 일반강도 초저수축 콘크리트의 특성 변화 연구)

  • Jeong, Jun-Young;Min, Kyung-Hwan;Lee, Dong-Gyu;Choi, Hong-sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.342-347
    • /
    • 2016
  • This study examined the effects of the coarse aggregate maximum size and grading of fine aggregates to acquire the characteristics of very low shrinkage on normal strength concrete mixed in the field. In addition, the shrinkage characteristics of concrete under construction were evaluated in accordance with the curing temperature. The compressive strength and drying shrinkage tests were performed for nine mixing factors composed of the coarse aggregate size (13, 20, and 25 mm), types of fine aggregate (see sand, crushed sand, and blended sand), and curing temperatures (5, 20, and $35^{\circ}C$). To acquire low shrinkage properties under $350{\mu}{\varepsilon}$ strain on normal strength concrete, a 25 mm maximum of coarse aggregate was available, and the grading of fine aggregate affected the shrinkage of concrete. In addition, very low shrinkage properties were acquired in the curing temperature range except cold and hot weather concrete.

Cryopreservation of Embryogenic Tissue and Plant Regeneration in Larix leptolepis (낙엽송 (Larix leptolepis) 배발생조직의 초저온보존 및 식물체 재분화)

  • Kim, Yong-Wook;Kim, Joon-Chul;Youn, Yang;Noh, Eu-Rae;Son, Sung-Ho
    • Korean Journal of Plant Tissue Culture
    • /
    • v.26 no.4
    • /
    • pp.229-233
    • /
    • 1999
  • The possibility for long-term preservation of Larix leptolepis embryogenic tissue was tested in this study. Higher relative increase of the tissue fresh weight was observed when embryogenic tissue was pretreated for 24 hrs in a medium containing 0.4 M sorbitol or 20% polyethyleneglycol with cooling rate of -0.33$^{\circ}C$/min. The fast cooling rate of -0.5$^{\circ}C$ and -1.$0^{\circ}C$/min appeared to be less effective in regrowth of tissues from cryopreservation. No DNA variants have been observed by PCR analysis among the embryogenic tissues recovered after 1-, 7-, and 28-day-cryopreservation. The post-thaw embryogenic tissue gave rise to mature somatic embryos which developed into plants.

  • PDF

The Mixed-Bed Ion Exchange Performance and Temperature Effects at Ultra-Low Concentrations - 2.Temperature Effects - (초저이온 농도범위에서 혼합층 이온교환능과 온도의 영향 - 2. 온도의 영향 -)

  • Yoon, Tae Kyung;Noh, Byeong Il;Lee, Chang Won;Moon, Byung Hyun;Lee, Gang Choon;Jo, Myung Chan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.206-211
    • /
    • 1999
  • Mixed-bed ion exchange performance was studied experimentally with variations of cation to anion resin ratio, resin weight and temperature at ultralow sodium chloride solution concentrations of less than $1.0{\times}10^{-4}M$. Analyzing the effluent concentration histories the performance test was examined as a function of tested solution volume for a laboratory-scale continuous flow column until both the cation and anion-exchange resins were exhausted. Initial leakage was observed for both cation and anion breakthrough curves, but serious at cation breakthrough curve because of low selectivity coefficient. The slope of breakthrough curve was affected by selectivity coefficient and temperature. The slope of anion breakthrough curve was steep because of the large selectivity coefficient, and ion exchange rates increased as temperature increased. The temperature effect decreased as the total volume was increased or as the resins were exhausted.

  • PDF

Review about Thermal Stability Reinforcing Method of the Concrete Sidewall of the LNG Storage Tank Using Sprayed PUF (스프레이 PUF를 이용한 LNG 저장탱크 외조 벽체의 열적 안정성 강화 방법에 대한 고찰)

  • Lee, Yeongbeom;Choe, Keonhyeong;Yoon, Ihnsoo;Han, Chonghun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • LNG storage tank is a facility to store liquefied natural gas (LNG) and its safety and stability to be greatly needed. When there is a LNG leakage in case of primary container problem, a special facility such as a bund wall should be constructed to store the leaked LNG. But this method makes the land usage inefficient and construction price high. So nowadays the full containment type LNG storage tank is selected instead of constructing a bund wall. In the full containment type tank, the concrete sidewall has the ability to store LNG temporarily. There are largely two methods to give the concrete sidewall the ability. In a method, rebar should be used when constructing the side wall of the LNG storage tank. In the other method, the protecting material such as sprayed polyurethane foam should be applied on the inner surface of the concrete sidewall. Sprayed PUF keeps the temperature of the sidewall above the specified temperature during the specified periods. Recently the thermal stability reinforcing method using sprayed polyurethane foam has been applied to all LNG storage tank built in Korea.

Effect of Injector Cooling on Ignition of Cryogenic Spray (분사기 냉각이 초저온 분무의 점화에 미치는 영향)

  • Kim, Do-Hun;Lee, Jin-Hyuk;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.222-229
    • /
    • 2012
  • The cooling of a injector effects on the vapor pressure of cryogenic oxidizer spray, and it decides the phase transition point at the ignition process, when the combustion chamber pressure increases drastically. The phase transition of oxidizer spray affects the ignition characteristics, and several ignition tests with the LOx/$GCH_4$ uni-element coaxial swirl injector was performed in the different initial temperatures of oxidizer injector, in order to investigate the effect of injector cooling on the ignition transient characteristics. At the transition point of oxidizer phase, where the combustion chamber pressure increased over the LOx vapor pressure, the temporary quenching phenomenon of the flame occurred. The lower temperature of chilled down injector and tubing tends to move up the phase transition earlier.

커패시터를 사용한 초저가의 교류전원 LED 최적 구동회로 개발

  • Lee, Byeong-Hun;Kim, Hyeon-Jae;Kim, Bong-Cheol;Im, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.426-427
    • /
    • 2010
  • 커패시터 소자와 브릿지 다이오드만을 사용한 교류전원 LED 구동회로를 분석하여, 초저손실 고효율 특성과 더불어 입력전류의 고조파 및 역률특성이 양호해지는 동작점을 찾아내었다. 커패시터 소자는 교류전원에 직렬로 연결되어 전력손실 없이 LED 전류를 제한하는 역할을 하게 되며, 브릿지 다이오드 정류회로는 LED 어레이를 교류전원의 2배 주파수로 구동시키게 한다. 분석결과, 제안된 LED 구동회로는 LED 어레이의 전압강하가 입력 교류전압 최대치의 절반이 될 때 역률특성과 효율이 최고가 되며, 동작온도 변화에 따른 LED 어레이 전압 변동에 대해 출력이 변하지 않는 특징을 갖는다. 이러한 LED 구동회로는 스윗칭 레귤레이터나 IC 등이 없이 단순 수동소자만을 사용함으로써 제품원가 최소화와 효율향상을 동시에 달성할 수 있으며, 실험을 통해 특성이 확인되었다.

  • PDF