• 제목/요약/키워드: 초임계의

검색결과 694건 처리시간 0.034초

유전자 알고리즘을 이용한 유연 복합재 구동축의 최적 설계 (Optimum Design of a Flexible Matrix Composite Driveshaft Using Genetic Algorithms)

  • 홍을표;신응수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.109-115
    • /
    • 2003
  • This study intends to provide an optimum design of flexible matrix composite driveshafts using a genetic algorithm. An objective function is defined as a combination of shaft flexibility, whirling stability and torsional buckling and the design variables are selected as ply angles and the shaft thickness. Results show that the genetic algorithm can successfully find an optimum solution at which the overall performance of the FMC shafts is significantly enhanced

  • PDF

에틸 아세토아세테이트 토토머리즘 평형 상수의 밀도 의존성 (The Effect of Solvent Density on the Ethyl Acetoaceate Tautomerism)

  • 박윤국
    • 공업화학
    • /
    • 제17권3호
    • /
    • pp.291-295
    • /
    • 2006
  • 본 연구에서는 아임계 및 초임계 이산화탄소하의 에틸 아세토아세테이트의 케토-에놀 토토머릭 평형상수를 후리에 적외선 분광기를 이용하여 세 가지 다른 온도에서 측정하였다. 케토-에놀 토토머릭 평형상수의 용매에 대한 밀도 의존성을 연구하기 위하여 정온하에서 이산화탄소의 압력을 변화시켰다. 용매인 이산화탄소의 밀도를 증가 시키면, 케토 토토머의 양이 증가하게 되어 케토-에놀 토토머릭 평형상수값이 감소한다. 에틸 아세토아세테이트의 케토-에놀 토토머릭 평형상수의 밀도의존성을 연구하기 위하여 변형된 격자유체수소결합 모델을 적용하였다.

초임계 유체를 위한 분자 클러스터 기반의 격자모델 (A Lattice Model Based Molecular Clusters for Supercritical Fluids)

  • 신문삼
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.306-309
    • /
    • 2011
  • A lattice model based molecular clusters is presented to improve a classical equation of state(EOS) for volumetric properties in the critical region. The term is based on the two assumptions: (1) The Helmholtz energy is individually divided into classical and long-range density fluctuation contribution (2) All molecules form cluster near the critical region due to long-range density fluctuation. To formulate such molecular cluster, we extended the Veytsman statistics originally developed for the cluster due to hydrogen bonding. The probability function in the statistics is modified to represent the characteristics of long-range density fluctuation vanishing far from critical region. The proposed fluctuation contribution was incorporated into the Sanchez-Lacombe EOS and the combined model with 6 adjustable parameters has been tested against experimental VLE data for pure compounds. The combined model is found to well represent flatten critical isotherm for methane and top of the coexistence curve for the tested components.

  • PDF

초임계 유체를 위한 분자 클러스터 기반의 격자모델 (A Lattice Model Based on Molecular Clusters for Supercritical Fluids)

  • 신문삼
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 춘계학술발표논문집 2부
    • /
    • pp.961-964
    • /
    • 2010
  • A semi-empirical fluctuation term is presented to improve a classical equation of state (EOS) for volumetric properties in the critical region. The term is based on the two assumptions: (1) The Helmholtz energy is individually divided into classical and long-range density fluctuation contribution (2) All molecules form cluster near the critical region due to long-range density fluctuation. To formulate such molecular cluster, we extended the Veytsman statistics originally developed for the cluster due to hydrogen bonding. The probability function in the statistics is modified to represent the characteristics of long-range density fluctuation vanishing far from critical region. The proposed fluctuation contribution was incorporated into the Sanchez-Lacombe EOS and the combined model with 6 adjustable parameters has been tested against experimental VLE data. The combined model is found to well represent flatten critical isotherm for methane and top of the coexistence curve for the tested components. The prediction results for caloric data are in good agreement with the experimental data.

  • PDF

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

축어긋남이 있는 유연복합재 고속구동축의 특성 분석 (Characterization of a Misaligned Supercritical Shaft of Flexible Matrix Composite)

  • 홍을표;신응수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.107-113
    • /
    • 2003
  • This research is to investigate the performance of a flexible matrix composite driveshaft with respect to shaft design parameters such as the number of layers, ply orientations, and material properties. A finite element formulation is utilized to estimate the allowable misalignment under given driving torque, the maximum temperature at steady states, and external damping for ensuring whirling stability under supercritical speed. Results indicate that the system performance can be greatly affected by the shaft laminate parameters, especially the ply orientations. Several sets of shaft parameters that will provide satisfactory overall system performance are derived.

  • PDF

초임계 이산화탄소를 이용만 맥주효모로부터 고미성분 제거 (Removal of the Bittering Substances from Brewer's yeast by Supercritical Carton Dioxide)

  • 전병수;윤성옥;김석규;최승태
    • KSBB Journal
    • /
    • 제17권1호
    • /
    • pp.68-72
    • /
    • 2002
  • 폐맥주효모로부터 Hop의 고미성분을 추출하는 최적조건은 이산화탄소 유량 50 mL/min, 입자크기 0.35 mm, 시료 20 g, 보조용매(95% 에탄올) 4 mL/min, 총 추출시간 30분, 추출온도 $45^{\circ}C$, 추출 압력 1800 psia로 원 시료와 비교한 결과 Hop의 향기 성분과 고미성분이 거의 제거됨을 알 수 있었다. 또한 보조용매의 효과는 추출물질의 표면적을 크게 하여 침투력을 높여주고 추출물 중의 휘발성이 강한 성분이나 색의 제거에 상당한 효과가 있음을 알 수 있었다(13,14).

곧은 사각채널을 통과하는 물성 변화가 큰 유동에 대한 수치해석 (NUMERICAL STUDIES ON FLOWS WITH STRONG PROPERTY VARIATIONS THROUGH STRAIGHT RECTANGULAR CHANNELS)

  • 최남정;최윤호
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.74-84
    • /
    • 2007
  • The flowfield characteristics in a straight rectangular channel have been investigated through a numerical model to analyze the regenerative cooling system that is used in rocket engine cooling. The supercritical hydrogen coolant introduces strong property variations that have a major influence on the developing flow and heat transfer characteristics. Of particular interest is the improved understanding of the physical characteristics of such flows through parametric studies. The approach used is a numerical solution of the full Navier-Stokes equations in the three dimensional form including the arbitrary equation of state and property variations. The present study compares constant and variable property solutions for both laminar and turbulent flow. For laminar flow, the variation of aspect ratio is examined, while for turbulent flow, the effects of variation of channel length and Reynolds number are discussed.

이젝터를 적용한 이산화탄소 냉동사이클의 내부열교환기 길이에 따른 성능 변화 (Performance Variation with Length of Internal Heat Exchanger in CO2 Cooling Cycle Using an Ejector)

  • 강변;조홍현
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.147-154
    • /
    • 2012
  • Recently, many researchers have studied the performance of the transcritical $CO_2$ refrigeration cycle in order to improve the system efficiency. In this study, the length of IHX in the $CO_2$ ejector cycle was varied so as to evaluate the performance improvement. As a result, compressor work and cooling capacity was increased by 3% and 5% as the length of internal heat exchanger was changed from 3 m to 15 m. The best COP was appeared at internal heat exchanger length of 12 m, and it was 3.01. Besides, the length of internal heat exchanger has a big effect to pressure lift ratio and entrainment ratio in the ejector $CO_2$ cycle and it may be changed with operating conditions and system specifications.