• Title/Summary/Keyword: 초음파 회절

Search Result 54, Processing Time 0.027 seconds

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Effectiveness of the Angular Spectrum Method for analysis of Acoustic near-field. (근거리 초음파 음장해석에 있어서의 각스펙트럼법의 유효성 검토)

  • 김정순
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.8-13
    • /
    • 1996
  • 균질 매질내에 형성되는 근거리 음장의 해석에는 종래 회절 이론에서의 Rayleigh 적분식에 근거한 Lommel 근사식이 주로 이용되어져 왔다. 그러나, 불균질한 매질에서는 그 방법의 적용이 어렵고, 유한요소법등 새로운 방법이 적용되어야 한다. 본 연구에서는 불균질 매질에서의 음장을 해석하는 한 방법으로 Angular Spectrum법을 제안하고, 경계를 가상한 등수온의 물에 대하여 Lommel 근사식에 의해 직접 산출한 음장과 Angular Spectrum법을 적용하여 산출한 음장을 서로 비교함으로써 그 유효성을 검토하였다.

  • PDF

A Evaluation of Penny-shaped Flaw by Analyzing a Ultrasonic spectrum (초음파 스펙트럼분석에 의한 동전형 결함 탐상)

  • 김흥기;전계석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.5
    • /
    • pp.46-50
    • /
    • 1991
  • 고체내부에 존재하는 결함의 에이지에서 회절되는 반사신호의 스페그럼을 해석하여 결함의 크기 를 결정하는 방법을 연구하였다. 실험을 위하여 순도 99.99%의 알루미늄 재료를 샘플로서선택하고 표면 에서 20mm 깊이에 반경 3500μm, 높이 1000μm 의 동전형 결함을 제작하였다. 결함의 탐상은 피치-캐 치법으로 하였으며, 스펙트럼분석에 의한 결함의 기존의 펄스 반사법에 의한 측정값과 비교하였다.

  • PDF

Effects of sonication on physicochemical properties and pore formation of maize starch (초음파처리가 옥수수전분의 이화학특성과 기공 형성에 미치는 영향)

  • Choi, Eun-Hee;Lee, Jae-Kwon
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.507-512
    • /
    • 2017
  • The physicochemical properties of maize starch sonicated at various amplitudes (100, 200, and 300 W) and times (10, 30, and 50 min) were examined. The amount of enzyme-susceptible starch increased marginally after sonication. Sonication increased the amount of oil absorbed in the starch although the degree of oil absorption decreased with an extension of the sonication time, implied that different types and extent of damages occurred. Scanning electron microscopy revealed that ultrasound sonication did not form pores on the surfaces, but caused damages such as depression and erosion. Pasting viscosity of starch decreased with an increase in the severity of sonication conditions because of the weakened polymer network. X-ray diffraction suggested that the crystalline domains in starch were not susceptible to sonication and were more resistance to degradation. Sonicated starch formed more pin-holes on the surfaces in the initial glucoamylase reaction; subsequently, as the reaction proceeded, porous starch with enlarged pores was formed and finally, disrupted granular fragments were observed.

Ultrasonic Velocity and Absorption Measurements for poly (sodium 4-styrenesulfonate) and Water Solutions (Poly (sodium 4-styrenesulfonate)/ 물 이성분용액의 초음파 음속 및 흡수계수측정)

  • 배종림
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.497-502
    • /
    • 2004
  • Both ultrasonic velocity at 3 MHz and absorption coefficient in the frequency range of 0.2-2 MHz were measured for poly (sodium 4-styrenesulfonate) aqueous solution over the concentration range of 5 to 25 % by weight. Pulse echo overlap method was employed to measure the ultrasonic velocity over the temperature range of 10-90 ℃ and the high-a ultrasonic resonator method was used for the absorption coefficient measurement at 20 ℃. The velocity exhibited a maximum value at approximately 55. 59, 63. 67, and 71 ℃ in 25, 20. 15, 10. and 5 wt% solutions, respectively. The velocity increased with poly (sodium 4-styrenesulfonate) concentration at a given temperature. The concentrations dependences of the relaxation frequency and amplitude showed that the relaxation around 200 kHz is related to the structural fluctuations of polymer molecules, such as the segmental motions of the polymer chains and that around 1 MHz resulted from the proton transfer reaction of the oxygen sites of SO₃. Both the absorption and the shear viscosity increase with the Polymer concentration. but decrease with temperature.

Effects of Ultrasonic Cleaning and Chemical Pre-treatment on the Characteristics of Fast-stabilized Rayon Fabrics (빠르게 안정화된 레이온직물의 특성에 미치는 초음파세척 및 화학전처리 영향)

  • Cho, Chae Wook;Cho, Donghwan
    • Journal of Adhesion and Interface
    • /
    • v.14 no.3
    • /
    • pp.146-159
    • /
    • 2013
  • In the present study, stabilized rayon fabrics were prepared from fast isothermal stabilization processes, which were carried out within four minutes at $350^{\circ}C$. The effects of ultrasonic cleaning and chemical pre-treatment on the chemical composition, physical characteristics, X-ray diffraction pattern, thermal stability and shape of the stabilized rayon fabrics were investigated extensively. In order to reduce the weight loss and thermal shrinkage of rayon fabrics occurring during the stabilization process, ultrasonic cleaning was first conducted and then chemical pre-treatments using $NH_4Cl$, $Na_3PO_4$, $H_3PO_4$, and $ZnCl_2$ were performed, respectively. The results indicated that both ultrasonic cleaning and chemical pre-treatment influenced the weight loss, thermal shrinkage, microstructure, carbon content, thermal stability and fabric shape of stabilized rayon fabrics. Also the results depended on the fast-stabilization time and the type of chemical pre-treatment agents used.

An Experimental Study on Estimation of Suspended Sediment Discharge using Acoustic Backscatter (실내 실험수로에서 초음파 산란도를 활용한 부유사량 산정)

  • Seo, KangHyeon;Kim, DongSu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.174-174
    • /
    • 2016
  • 하천은 침식작용과 퇴적작용에 의해 유사를 하류방향으로 이동시킨다. 하천의 침식작용은 하상을 변화시키고 교량, 보 등의 하천 구조물의 안전성을 저해하여 국민의 재산과 생명에 막대한 피해를 입힌다. 또한 퇴적작용은 상류로부터 이동한 유사를 하도 내에 퇴적시켜 하천의 형상을 변화시키고, 통수면적을 감소시켜 홍수기에 범람 빈도와 규모를 증가시킨다. 이처럼 부유사 자료는 하천 구조물의 설계, 수자원 개발 및 관리를 위한 하천계획의 전반에 있어 매우 중요한 자료이지만, 국내의 경우 유사량 측정방법에 대한 연구가 미비하여 대부분 유사량 채집기를 활용한 직접 측정이 이루어지고 있다. 하지만 유사량 채집기를 활용한 관측은 매우 제한된 지역에서 간헐적으로 실시되고 있어 측정 자료가 부족한 실정이다. 이러한 한계를 극복하고자 간접적인 측정 방식을 개발하였으나 우리나라의 강우 특성상 홍수기를 거치면서 하천의 수리학적 특성이 변화하여 관계식의 신뢰도가 떨어지며 자주 갱신해야 한다는 어려움이 있다. 본 연구에서는 횡방향 유속과 신호대잡음비(Signal to Noise Ratio, SNR)를 측정하는 H-ADCP(SonTek, SL-3000)와 레이저 회절을 이용하여 지점의 입도분포와 부유사 농도를 측정하는 레이저부유사측정기(LISST : Laser In-Situ Scattering and Transmissometry)를 이용하여 자료를 취득하였다. 그리고 취득된 신호대잡음비, 부유사 농도간의 관계분석을 통해 회귀식을 구축한 후, 초음파 산란도로 정의되는 신호대잡음비를 활용하여 실내 실험수로의 부유사량을 산정하였고 실측 부유사량과의 비교를 통해 오차 분석을 실시하였다. 오차 분석 결과 실측 부유사량은 138.15g/s, 추정 부유사량은 165.372g/s로 신호대잡음비를 이용하여 추정한 부유사량이 약 19% 과다산정 하는 것으로 나타났다. 본 연구의 결과는 현재 우리나라에 다수 설치되어 있는 수평초음파도플러유속계(H-ADCP)를 활용한 지속적인 부유사량 관측의 토대를 마련할 것으로 사료된다.

  • PDF

Fabrication of transducer optimized acousto optic modulator for laser projection display (Transducer 최적화 설계에 의한 Laser Projection Display용 음향광학변조기 제작 및 특성평가에 대한 연구)

  • 차승남;이항우;김용훈;황영모
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.5
    • /
    • pp.410-414
    • /
    • 1997
  • Laser projection display is a full color display system for large area. In this system, laser beams are modulated at acousto optic modulators(AOM) according to the video signal. AOM consists of a $TeO_2$ crystal and a $LiNbO_3$ transducer. We calculated the acoustic wave propagating from transducer to acousto optic media and made AOM by the calculated results. We compared calculated results with fabricated AOM by measuring modulation efficiency at various frequency. The modulation efficiency of AOM is 85% at the carrier frequency of 144MHz and the rise time is 41.5 ns.

  • PDF

Texture of Ultrasonic Weld Interface in Metals (초음파 용접 계면의 집합 조직)

  • 김인수;김성진;이민구;이응종
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.03a
    • /
    • pp.73-80
    • /
    • 1996
  • Commerical purity aluminium , copper and STS 304 stainless steel sheets are welded by ultrasonic welding. The microstructures, x-ray diffraction profiles of planes , pole figures of the surface of original metal sheets are compared with those of the weld interface. The microstructures show disturbance and dark areas in the weld interface and grain refinement in the vicinity of the interface. The x-ray diffraction intensity of each plane in weld interface decreased in all metal sheets with exception of 9200) in steel sheet. The microstructure and x-ray diffraction intensity is affected by the mixture of deformation, heating and vibratin duringthe ultrasonic welding. Therefore, after the ultrasonic welding, the positions of the peak intensity in the pole figures are changed, the value of the maximum pole intensity is decreased in Al, is increased in copper and stainless steel. Very strong {100} <001> texture, strong {100} <001>,{123}<634> textures in original Al surface are transformed into weak, {100}<001>, {110}<112> and {112}<111> components in weld surface, weak (110) fiber is slightly changed to (110) fiber in copper, (100)and ${\gamma}$ fiber components are transformed into strong ${\gamma}$ fiber component in stainless steel.

  • PDF

Evaluation of Characteristic for SS400 and STS304 Steel by Weld Thermal Cycle Simulation - 3rd Report: Residual Stress and Ultrasonic Parameter (용접열사이클 재현에 의한 SS400강 및 STS304강의 특성 평가 - 제3보: 잔류응력과 초음파 파라미터)

  • Ahn, Seok-Hwan;Choi, Moon-Oh;Jeong, Jeong-Hwan;Kim, Sung-Kwang;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.27-34
    • /
    • 2008
  • The temperature distribution in the weldment is not uniform because a weldment is locally heated. Thermal plastic deformation results from the local expansion and shrinkage by the heating and cooling of metal. Therefore, residual stresses and distortion occur in the weldment. In this study, we had conducted on the weld thermal cycle simulation that is supposed as the HAZ on SS400 steel and STS304 steel. The residual stresses that were obtained from the drawing and the weld thermal cycle simulation were estimated by X-ray diffraction. We also carried out ultrasonic test for the weld thermal cycle simulated specimens, and then conducted on nondestructive evaluation by the ultrasonic parameters obtained ultrasonic test. From the results, residual stresses of weld thermal cycle simulated specimens after the residual stress removal heat treatment are lower than that of the drawing.