Effects of a Carbohydrase Mixture, Ultrasound, and Irradiation Treatments on the Physical Properties of Defatted Mustard Meal-based Edible Films (탈지 겨자씨로 제조한 가식성 생고분자 필름의 물리적 특성에 대한 탄수화물 가수분해 효소 혼합체, 초음파, 그리고 방사선 처리의 효과)

  • Yang, Hee-Jae;Noh, Bong-Soo;Kim, Jae-Hun;Min, Sea-C.
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.30-38
    • /
    • 2011
  • Effects of depolymerization treatments of a carbohydrase mixture (CM), ultrasound, and irradiation on the physical properties of defatted mustard meal-based edible films (DMM films) were investigated. DMM hydrocolloids were added to CM (0.42% (w/w solution)), treated by ultrasound (500-700 W, 10-30 min) or ${\gamma}$-ray (40-100 kGy) to prepare film-forming solutions. Films were formed by drying. The CM treatment at 0.42% (w/w), pH 5.5, and 40-$50^{\circ}C$ with a 0.5 hr incubation time resulted in the highest colloidal stability in the film-forming solution. The depolymerization treatments did not dramatically change the water vapor permeability of the films. The solubility of the film decreased up to 53.1% by the CM treatment. The ultrasound treatment (700 W-30 min) decreased tensile strength and elongation. The ultrasound treatment (600 W-20 min) resulted in more compact and uniform structures of the films. Flavor profiles were differentiated by the power level and the time of the ultrasound treatment.

Optimal Design and Analysis of a Medical Imaging Ultrasonic Array Sensor (의료 영상진단용 초음파 어레이 센서의 최적설계 및 특성해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.263-270
    • /
    • 2008
  • The performance of an ultrasonic array sensor is determined by the properties of constituent materials and the effects of many structural parameters. In this study, with the finite element method, variation of the performances of an ultrasonic array sensor was analyzed in relation to its structural variables. Based on the analysis result, the structure of the ultrasonic array sensor was optimized to provide the highest sensitivity while satisfying such requirements as fractional bandwidth, center frequency and -20 dB pulse length. The optimization was carried out with the SQP-PD method for a target function composed of the ultrasonic array sensor performance. The optimized ultrasonic array sensor satisfied all the required specifications to be applicable to medical imaging diagnosis. The design technology in this paper can be utilized for other ultrasonic array sensors of a similar structure.

Theoretical investigation of vibrational characteristics of a multi-layered piezoelectric element for ultrasonic transducers (초음파 탐촉자용 다층 압전접합체의 진동특성에 관한 이론적 해석)

  • Jang Hwan Soo;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.383-386
    • /
    • 1999
  • 본 연구에서는 공중용 초음파 센서에 많이 사용되고 있는 원판형 압전소자, 정합층, 그리고 후면충, 세 부분으로 이루어진 다층 접합체의 진동 특성을 기계적 진동 방정식을 이용하여 이론적으로 해석하였으며, 해석결과의 타당성을 유한요소 해석방법을 사용하여 검증하였다. 본 연구의 해석 방법은 다층 판, 특히 압전세라믹과 정합층으로 이루어진 2층과 후면층이 추가된 3층에 대한 진동 방정식에 적절한 경계 조건 및 수렴조건을 적용하여 고유진동 주파수를 유도하였다. 그리고 이를 이용하여 초음파 탐측자 개발 시 널리 사용되고 있는 설계변수 즉, 각 층의 반경, 두께, 밀도, 그리고 영률의 변화에 대한 공진주파수의 변화 경향을 분석하였다. 공진주파수 변화 경향에 대한 이 해석 방법의 타당성을 널리 사용되고 있는 유한 요소해석법을 사용하여 검증한 결과, 두 해석결과는 좋은 일치를 보였다. 그러므로 본 연구의 결과는 종래의 등가회로나 유한요소 해석법에 비해 더 간편하고, 더 정확한 해석결과를 제공할 수 있는 해석도구로써 이용될 수 있을 것이다.

  • PDF

PERFORMANCE ANALYSIS OF ULTRASONIC TRANSDUCERS ; SIMULATION AND EXPERIMENTS (시뮬레이션과 실험에 의한 초음파 transducer의 성능 해석)

  • 이병호
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1985.10a
    • /
    • pp.23-26
    • /
    • 1985
  • 압전형 초음파 변화자의 특성을 압전체, matching layer, backing, 매질, tuning 및 구동 회로를 고려하여 해석하였다. 압전체는 KLM 모델을 이용하였고 모델변수를 실험적으로 추정하여 시뮬레이션에 대입하였다. 실험적인 RTIL(Round Trip Insertion Loss)은 면반사(plane reflection)에 대한 pulse-echo를 측정하여 계산되었으며, 이론치와 비교할 때 6-dB 주파수 대역내에서 2-dB 이하의 오차가 관찰되었다.

  • PDF

Peformance Analysis of Piezoelectric Ultrasonic Transducers ; Simulation and Experiments (압전형 초음파 변환자의 성능 해석 시뮬레이션 및 실험)

  • 이종현;성굉모;이병호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.16-20
    • /
    • 1985
  • 압전형 초음파 변환자의 특성을 압전체, matching layer, backing, 매질, tuning 및 구동 회로를 고려하여 해석하였다. 압전체는 KLM 모델을 이용하였고, 모델변수를 실험적으로 추정하여 시뮬레이션 에 대입하였다. 실험적인 RTIL은 면반사에 대한 pulse-echo를 측정하여 계산하였으며, 이론치와 비교할 때 20 dB 주파수 대역내에서 3 dB 이하의 오차가 관찰되었다.

  • PDF

Estimation of Equivalent Circuit Parameters for Dual Resonance Electroacoustic Transducer Using Iterative Levy Method (두 개의 공진점을 갖는 광대역 초음파 전기음향 변환기의 등가회로변수 추정)

  • Lim, Jun-Seok;Pyeon, Yong-Guk
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.18-23
    • /
    • 2012
  • A method to determine the equivalent circuits of broadband ultrasound transducers is necessary for designing filters that match the impedances of the transducer and the analysis of the transducer. A method is proposed to determine the equivalent circuits of broadband transducers with 2 resonances in the frequency band of interest. The circuit parameters are estimated by iterative Levy method with the measured electrical conductance data. The method is illustrated by computing the conductance and susceptance of the equivalent circuits of 3 types of broadband transducers. The equivalent circuit of a transducer.

Classification of Liver Disease by using Coarseness parameters of Ultrasonic Images (초음파 영상의 거칠기 변수를 이용한 간 질환 분류)

  • Lee, D.H.;Lee, Y.W.;Song, I.C.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.52-57
    • /
    • 1994
  • 간 기능 진단에 초음파 영상이 가장 많이 이용되고 있다. 간이 나빠지면 간 표면의 입자가 굵어지고 이것이 영상에서는 밝기(intensity)와 입자의 거칠기(Coarseness)가 높아지는 등의 특성이 나타난다. 진단에 사용되는 인자는 표면의 거칠기와 밝기 외에도 소엽의 크기와 모양 그리고 문맥 혈관의 크기 등도 고려가 된다. 초음파상으로 이러한 크기와 모양의 구분은 그렇게 어렵지 않다. 그러나, 영상의 밝기와 거칠기의 미세한 변화는 구분하기가 어렵다. 본 연구는 밝기와 거칠기를 나타내는 변수를 제시하고 이를 기준으로 간 질환을 분류하였다. 간 조직의 거칠기에 따라 크게 정상(Normal), 만성 간염(Chronic), 간경변증(Cirrhosis) 세단계로 질환의 상태를 진단하고 영상의 밝기에 따라 다른 간질환과 지방간(fat liver)을 구별해 낸다. 본 분석에 이용된 임상 영상은 주로 만성 간염과 간경변증을 갖고 있는 환자들의 것과 약간의 지방간 영상들이다.

  • PDF

Extraction of Useful component from Natural plants using Ultrasound system (초음파 시스템을 이용한 천연물로부터 유용성분의 추출)

  • Lee, Kwang-Jin;Um, Byung-Hun
    • KSBB Journal
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 2008
  • Ultrasound assisted extraction (UAE) process enhancement for food and allied industries are reported in this review. Recently ultrasound system has been used more frequently to extract drugs and natural substances. This modern emulsification, homogenization, particle size reduction and viscosity alteration methodologies require reliable tools that perform on a high level in terms of efficiency and reproducibility. Also, Ultrasound can enhance existing extraction processes and enable new commercial extraction opportunities and processes. Therefore, ultrasound technologies could have a strong presence in the future of the food industry.

Korean Institute of Ceramic Eng. & Tech. (수도계량기용 초음파 유량센서의 설계 및 평가)

  • Lee, Young-Jin;Paik, Jong-Hoo;Jeong, Young-Hun;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.364-364
    • /
    • 2008
  • 유한요소해석을 통하여 수도계량기용 삽입형 초음파 유량계 압전 트랜스듀서의 설계를 실시하고 이를 평가하였다. 상용 해석프로그램인 PzFlex를 사용하여 센서의 transient 해석을 실시하였다. 이를 통해 각 구성부품의 재질 및 형상 변수를 결정하였다. 이를 기준으로 트랜스듀서를 제작하였으며, 두께모드 중심주파수가 1.2MHz가 되도록 직경 10mm의 압전소자를 이용하였다. 시뮬레이션을 통해 $25^{\circ}$의 방사각으로 음향파가 발생되도록 트랜스듀서를 설계, 제작한 후, 트랜스듀서의 전기적, 기계적 특성을 평가하였다.

  • PDF

Parameter Estimation of Tissue Structure Characteristics in Ultrasound Measurement (초음파를 이용한 조직구조 특성변수의 측정)

  • 곽철은;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 1986
  • The objective of tissue characterization is to provide quantitative information about the physical state of tissue interrogated by an ultrasound beam. In the computer simulation, it was found that the echoes were composed of the interferences of the ultrasonic waves reflected from both sides of the thin object, and could be separated by the spectral correlation method. Also, the phantom study demonstrates that thickness of the thin acryl layer beyond the resolution of common ultrasonic imaging systems can be measured- using this method.