• Title/Summary/Keyword: 초음파 진단기

Search Result 202, Processing Time 0.032 seconds

초음파 진단기산업의 현황과 전망

  • 이민화
    • 전기의세계
    • /
    • v.38 no.12
    • /
    • pp.12-16
    • /
    • 1989
  • 초음파 진단기산업은 꾸준히 증가하는 성장기산업으로써 1990년대와 2000년대에 형성될 초음파 진단기의 시장은 다음의 몇가지 과제를 던져주고 있다. 1. 초음파 진단기는 천단전자산업의 하나이므로 제품의 경쟁력은 효율적 연구, 개발에서 찾아야 할것이다. 즉 급변하는 전자기술의 추세에 대응하기 위하여 유연한 조직하에서 부단히 연구하는 자세가 필요하다. 2. 부단한 연구, 개발의 산물인 technology를 이용하여 Market Pull이 아닌 Technology Push로서 새로운 시장을 창출해 나가야 할 것이다.

  • PDF

International Health Project for Improving the Level of Mother and Child Health in Developing Countries: Focusing on KOICA CTS Cases in Vietnam (개발도상국 모자보건 수준 향상을 위한 국제보건사업: 베트남 KOICA CTS 사례를 중심으로)

  • Choung, Yoo-Chan;Shin, Jae-wan
    • Journal of Appropriate Technology
    • /
    • v.6 no.1
    • /
    • pp.45-50
    • /
    • 2020
  • We developed the world's first wireless ultrasound diagnostic device. For the smooth delivery of pregnant women, the WHO requires four prior examinations, and the use of ultrasound diagnostic devices is essential for this purpose. However, income levels and medical facilities in developing countries are falling short. We conducted KOICA's CTS program in Vietnam using a self-developed radio ultrasound diagnostic device. We supplied Sonon300C, a portable wireless ultrasound diagnostic device, to health centers and hospitals in Huong-Hoa district, Vietnam, and conducted an outreach program in an effort to further enhance business performance. As a result, the rate of ultrasound diagnostics in the region reached 100% and the percentage of trained graduates increased to 59%.

A Study on the Cross Talk Level in a Medical Piezoelectric Ultrasonic Array Transducer (의료용 압전 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • Kim Young-Shin;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.349-352
    • /
    • 2002
  • 초음파 진단용으로 널리 사용되는 1차원 배열 압전형 초음파 변환기는 변환기내의 인접한 소자들간의 간섭에 의해 그 특성에 많은 영향을 받는다. 특히 각 소자 사이에 위치한 커프 및 음향 벽의 형상은 변환기 내 음향 간섭에 매우 큰 영향을 미친다. 그러므로 본 연구에서는 일반적으로 복부진단용으로 사용되는 압전형 1차원 배열 의료용 초음파 변환기에서 커프 및 음향 벽의 형상에 따른 음향간섭 레벨의 변화 경향을 유한 요소 해석법을 이용하여 분석하였다. 해석 결과를 바탕으로 소자간 음향간섭을 일으키는 원인을 규명하고, 나아가 음향 간섭레벨을 최소화하기 위한 구조적 방안을 도출하였다. 이러한 연구 결과는 향후 진단용 초음파 변환기의 최적 설계를 위해 중요한 자료가 될 것이며, 의료 치료용, 비파괴 검사용, 그리고 수중 초음파 변환기에도 적용이 가능할 것이다.

  • PDF

An Improvement of the Lateral Resolution of Linear Array Transducer for Medical Ultrasonic Imaging (의료 진단용 선형 배열 변화기의 측 방향 해상도 개선)

  • 백승한
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.136-141
    • /
    • 1991
  • 초음파 영상 진단기에서 영상의 질을 높이기 위해서는 넓은 범우에서 높은 측 방향 해상도가 요구된다. 측 방향 해상도는 변환기에 의해 발생되는 초음파 빔폭에 의해 좌우되는데 기존의 변환기는 초점 부근에서는 빔폭이 매우 좁으나 집속 범위가 제한되는 단점이 있다. 본 논문에서는 넓은 범위에서 균일한 빔폭을 얻을 수 있는 새로운 형태의 변환기를 제안하고 변환기에 의한 음장 분포를 전산기 모의 실험을 통해 구하였으며 그 결과 초점 부근에서는 빔 폭이 기존의 변환기에 비해 다소 넓어지나 집속 범위가 기존의 변화기에 비해 넓어지는 것을 확인할 수 있었다.

  • PDF

The Accuracy of Echocardiography and ECG in the Left Ventricular Hypertrophy (좌심실비대 진단에서 심장초음파와 심전도검사의 정확성)

  • Yang, SungHee;Lee, Jin-Soo;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.666-672
    • /
    • 2016
  • We extracted 50 LVH patients out of 30'~80's who performing ECG and echocardiography examination. We used Devereux's theory to examinate LVH with echocardiography and used Sokolow-Lyon's theory to examinate LVH with ECG. We used regression and correlation analysis by SPSS, used ROC curve analysis to decide predominance of two ways of .Age, BMI, SBP and DBP whice are the danger factors of LVH and standard value of LVH diagnosis examination seems correlated. Out of 50 LVH patients, 50 patients were diagnosed LVH by echcardiography examination and only 21 patients were diagnosed LVH by ECG examination. Also echocardiography was AUC 99%, sensitivity 96%, singularity 95%, accuracy 95.5%. And ECG was AUC 76%, sensitivity 62%, singularity 76%, accuracy 68%.By comparing accuracy between echocardiography and ECG in diagnosing LVH, we could tell echocardiography was examination with higher accuracy. Therefore, if one was diagnosed with summit on 1st examination with ECG, considering age, body mass index, systolic blood pressure and dilator blood pressure, should offer echocardiography examination.

A Study on the Cross Talk Level in a Piezoelectric Ultrasonic Array Transducer (압전형 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • 이수성;김영신;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.56-61
    • /
    • 2002
  • In piezoelectric ultrasonic linear array transducers widely used for diagnosis, the cross talk caused by the structural cross-coupling between adjacent elements inside the transducer affects the probe performance in a significant manner. In this study, we constructed a finite element model of a piezoelectric ultrasonic transducer, and analyzed its cross talk level with respect to the shape of and materials inside the kerf, The results of this work can be utilized in optimal design of the transducers for medical diagonosis and treatment as well as W applications.

Design and Fabrication of Linear Array Transducer for Ultrasonic Medical Imaging System (초음파 의료 진단기용 선형 배열 변환기의 설계 및 제작)

  • 조영환;성굉모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.6
    • /
    • pp.43-51
    • /
    • 1991
  • 본 논문에서는 초음파 의료 진단기용 선형 배열 변환기의 설계 및 제작을 수행하였다. 설계시에 는 펄스 인가시의 경우 유용한 등가회로인 KLM 모델을 이용한 전산기의 모의실험을 행하였다. 설계된 변환기는 동작 주파수 3.5MHz, 길이 120mm인 변환기이며 폭은 13mm이며 8개의 부소자로 이루어진 64 개의 소자를 갖는 변환기이다. 설계, 제작된 변환기는 효율적인 에너지 전달과 광대역 특성을 갖도록 하 기 위하여 2개의 음향 정합창을 갖도록 하였으며 압전 물질의 형태에 의해 집속되도록 하였다. 제작된 변환기의 성능 비교를 위해 제작된 변환기와 상용의 변환기의 성능을 동일한 조건에서 측정하였다. 측 정결과, 제작된 변환기는 우수한 성능을 갖는 것을 확인하였으며 실제 초음파 영상진단기에 사용할 경 우 좋은 상을 얻을 수 있다.

  • PDF

A Study on the Detection of Ultrasonic Signal for the Diagnosis of Transformer (변압기 예방진단을 위한 초음파 신호 검출에 관한 연구)

  • 권동진;광희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.65-70
    • /
    • 1995
  • This paper describes the detection of the ultrasonic signals reduced by materials of a transformer for diagnosis of the transformer using ultrasonic signal which is generated by partial discharge. When partial discharge is generated on the surface of the winding and between the winding and the core in the transformer, the ultrasonic signal can be measured as the proper selection of the ultrasonic detectors' location.

  • PDF

Fault Diagnosis of M.tr using Acoustic Sensor Technique (초음파 기술을 이용한 변압기 이상상태 진단)

  • Jeong, Jae-Ki;Yoon, Si-Young;Kang, Chang-Ik;Jin, Young-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.744-745
    • /
    • 2007
  • 변압기를 진단하는 분석 요소 중 흔히 사용하는 방법으로 유중가스분석을 이용하는 방식을 많이 사용하고 있다. 유중가스 분석은 변압기 내 Oil이 열과 Arc등에 의해 화학적으로 변화된 것을 측정하여 열화 정도를 추정하는 방식이지만 신속한 검출 및 위치추정이 불가능하다는 단점이 있다. 신속한 검출이 되지 않으면 신속한 보고가 이루어 질 수 없으므로 변압기 교체시점을 맞추지 못하여 사고로 인한 막대한 피해보상이 발생한다. 이런 단점을 보완하기 위해 변압기내 부분방전 및 Arc에 의해 발생하는 부분방전신호를 초음파 대역에서 검출하여 열화 및 위치를 추정할 수 있는 초음파 분석이 필요하게 되었고 실험을 통해 변압기에 대한 분석, 진단을 시행하였다.

  • PDF