• Title/Summary/Keyword: 초음파 주사

Search Result 198, Processing Time 0.03 seconds

Diagnostic Usefulness of Tc-99m Tetrofosmin Scintimnmmography in Patients with Primary Breast Cancer (유방암 환자에서 Tc-99m Tetrofosmin Scintimammography의 진단적 유용성)

  • Park, Ki-Han;Kim, Chang-Guhn;Yoon, Kwon-Ha;Choi, Si-Sung;Lee, Jong-Deok;Lee, Kwang-Man;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.5
    • /
    • pp.452-460
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the diagnostic usefulness of scintimammography per-formed with Tc-99m tetrofosmin in the detection of primary breast cancer Materials and Methods: Sixty-one patients underwent Tc-99m tetrofosmin scintimammography, plain-film mammography and ultrasonography. After intravenous injection of Tc-99m tetrofosmin (740 MBq), prone lateral and anterior scintimammograms were obtained. Scintimammogram was visually interpreted as positive, probably positive, probably negative and negative for malignancy. The tumor to background count ratio (T/B) was measured at 5 minutes and 1 hour. Plain-film mammogram was interpreted as one of 5 categories. Final diagnosis was achieved by surgical histology (58/61) or fine needle aspiration (3/61). Of 61 patients, 44 had cancer and 17 had benign lesion. Tumor size of malignant and benign lesions on ultrasonogram were $2.51{\pm}1.30cm$ (range 1-8 cm), $2.50{\pm}1.35cm$ (range 0.96-6 cm), respectively. Results: The sensitivity of plain-film mammography was 88.6%, specificity 58.8%, positive predictive value 84.7%, and negative predictive value 66.7% The sensitivity of Tc-99m tetrofosmin scintimammography was 90.9%; specificity, 88.2%; positive predictive value, 94.9%, negative predictive value, 18.9%. Of 25 patients with indeterminate degree of suspicion for malignancy on plain-film mammogram, 23 were correctly diagnosed by scintimammography. The T/B at 5 minutes and 1 hour were $3.78{\pm}2.21$, $3.25{\pm}1.80$ respectively. The T/B was decreased significantly at 1 hour (p<0.001). Conclusion: Tc-99m tetrofosmin scintimammography was useful dia-gnostic procedure in the detection of primary breast cancer, especially in patients with indeterminate degree of suspicion for malignancy on plain-film mammogram.

  • PDF

Analysis of transmissivity tensor in an anisotropic aquifer (이방성 대수층에서의 투수량계수텐서 해석)

  • 강철희;이대하;김구영;이철우;김용제;우남칠
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.53-61
    • /
    • 2002
  • An Aquifer test was carried out on five boreholes to determine the hydrologic anisotropy and the major groundwater flow direction in the aquifer system of the study area. With an assumption of the aquifer's anisotropy and homogeneity, the major transmissivity(T(equation omitted)), the minor transmissivity( $T_{ηη}$ ), and primary tensor direction ($\theta$) for each borehole were determined from the test. Besides the boreholes BH-1, BH-4 and BH-5, the anisotropy transmissivity tensor values of BH-2 and BH-3 did not correspond with the assumption. Thereafter the values were plotted on the polar coordinate, and showed that the tensor values were out of the anisotropy ellipsoid due to the high heterogeneity of BH-2 and BH-3 comparing with the other boreholes. Therefore. the anisotropy of the aquifer was examined from BH-1, BH-4. and BH-5. In BH-1, T(equation omitted) is 171.9 $\m^2$/day. $T_{ηη}$ is $71.01\m^2$/day, and the principal tensor direction is Nl5.39$^{\circ}$E. In BH-4. T(equation omitted) is $268.2 \m^2$/day, $T_{ηη}$ / is $28.75\m^2$/day and the principal tensor direction is N7.55$^{\circ}$E. In BH-5, T(equation omitted) is $168.4\m^2$/day, $T_{ηη}$ is 66.80 $\m^2$/day, and the principal tensor direction is $N76.59^{\circ}$E. On the basis of teleview logging performed on each borehole. the principal fracture directions were revealed as $N0^{\circ}$~4$^{\circ}$E/$30^{\circ}$~$50^{\circ}$SE and $N30^{\circ}$~$80^{\circ}$W/$20^{\circ}$~$50^{\circ}$NE that are the most frequently occurred sets as well as that correspond well with the calculated transmissivity tensor.

Relationship between Various Estrous Behavioral Signs and Ovulation Time in Dairy Cows (젖소의 다양한 발정 행동 징후와 배란 시간과의 관계)

  • Son, J.K.;Park, S.B.;Park, S.J.;Baek, K.S.;Ahn, B.S.;Kim, H.S.;Hwang, S.J.;Ju, J.C.;Park, C.K.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • The objective of this study was to investigate the relationship between various estrous behavior and ovulation time, and to determine which estrous behavior could predict ovulation time more accurately. In total, 37 ovulations and 28 estrous detection were observed in 51 Holstein-Friesian dairy cows. Various estrous behavior were observed during 72 h from two days after $PGF_2{\alpha}$ injection and their relation with the time of ovulation (ultrasound examinations at 4-h intervals) was investigated. In estrous periods, the rate of sniffing, chin resting, mounting, standing heat was 81%, 78%, 78% and 56%, respectively. Ovulation occurred $25.6{\pm}7.9h$ after onset of estrus (ranging between 7 and 37h) and $13.4{\pm}7.1h$ after end of estrus (ranging between 1 and 28h). Interval between onset of estrus and ovulation time was significantly (p<0.05) shorter for standing heat $(17.33{\pm}5.83h)$ than for mounting, sniffing and chin resting $(23.58{\pm}5.12h,\;24.25{\pm}6.09h,\;23.42{\pm}6.04h)$. In 88% of the animals that displayed mounting, ovulation occurred between $16{\sim}28h$ after onset of mounting. Onset of standing heat, sniffing and chin resting occurred between $10{\sim}22(81%)h,\;16{\sim}28(79%)h\;and\; 19{\sim}31(79%)h$ before ovulation respectively. Sniffing and chin resting were displayed during the non-estrous period and are therefore, not useful predictors of ovulation time. The standing heat and mounting can be a good predictor for time of ovulation but the disadvantage of using standing heat is that only a limited number of cows display standing heat. Thus, it is concluded that mounting behavior could be the best predictor for time of ovulation.

Urinary Tract Infection and Vesicoureteral Reflux in Children (소아에서의 요로감염과 방광요관역류에 관한 고찰)

  • Lim Hyun-Suk;Park Chang-Ro;Ko Cheol-Woo;Koo Ja-Hoon
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 1997
  • Urinary tract infection (UTI) in children has been known to be a cause of renal damage, leading to scar formation, hypertension and renal failure. And vesico-ureteral reflex (VUR), frequently accompanying UTI in young children, has been incriminated as the main factor causing scar formation. This retrospective study has been undertaken to see the relationship among UTI, VUR and renal scar formation. Study population consisted of 291 children (boy 134, girl 42) with UTI, who have been admitted to the Pediatric Department of Kyungpook University Hospital during 6 1/2 year period from January 1990 to June 1996. VUR was diagnosed by VCUG and renal scar by ultrasonogram, DMSA scan (or DMSA SPECT) and IVP. The following result were obtained. Sexual difference showed male predominance (male to female, 134:42) below 1 year of age, and female predominance (male to female, 11:35) over 5 years of age were rioted. VUR has been found in 64 children (22%) and the degree of reflux, classfied by the method proposed by 'International Reflux Study in Children', were as follows ; Grade I : 4.0%, Grade II : 3.0%, Grade III : 2.7%, Grade IV : 5.8% and Grade V : 6.2%. There was no sexual difference E.coli was the most predominant infecting agent occurring in 167 children (57%), and end-stage renal failure was diagnosed at the time of first admission in 5 children with Grade V VUR. Renal scar has been noted in 49 out of 582 kidneys (8.4%), and the incidence of scar foramation according to the degree of VUR were as follow ; Grade 0 (No reflux) : 1.2%, Grade I : 6.7%, Grade II 27.3%, Grade III 29.4%, Grade IV : 57.1%, and Grade V : 100%. In summary, present study shows that renal scar formation in UTI has close correlation with the severity of VUR occurring more frequently in severe reflux, so that early diagnosis and proper treatment of UTI and VUR is of paramount importance in preventing renal damage in children with UTI.

  • PDF

Identification of Conductive Fractures in Crystalline Recks (유동성 단열 파악을 위한 암반 내 단열특성 규명)

  • 채병곤;최영섭;이대하;김원영;이승구;김중렬
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.2
    • /
    • pp.88-100
    • /
    • 1998
  • Since fractures may serve as major conduits of groundwater flow in crystalline rocks, characterization of conductive fractures is especially important for interpretation of flow system. In this study, characterization of fractures to investigate hydraulically conductive fractures in gneisses at an abandoned mine area was performed. The orientation, width, length, movement sense, infilling materials, spacing, aperture, roughness of both joints and faults and intersection and connectivity to other joints were measured on outcrops. In addition, characteristics of subsurface fractures were examined by core logging in five boreholes, of which the orientations were acquired by acoustic televiewer logging from three boreholes. The dominant fracture sets were grouped from outcrops; GSet 1: N50-82$^{\circ}$E/55-90$^{\circ}$SE, GSet 2: N2-8$^{\circ}$E/56-86$^{\circ}$SE, GSet 3: N46-72$^{\circ}$W/60-85$^{\circ}$NE, GSet 4:Nl2-38$^{\circ}$W/15-40$^{\circ}$SW and from subsurface; HSet 1: N50-90$^{\circ}$E/55-90$^{\circ}$SE, HSet 2: N10-30$^{\circ}$E/50-70$^{\circ}$SE, HSet 3: N20-60$^{\circ}$W/50-80$^{\circ}$NE, HSet 4: N10-50$^{\circ}$E/$\leq$40$^{\circ}$NW. Among them, GSet 1, GSet 3 and HSet 1, HSet 3 are the most intensely developed fracture sets in the study area. The mean fracture spacings of HSet 1 are 30-47cm and code 1 fractures, such as faults and open fractures, comprise 21.0-42.9 percent of the whole fractures in each borehole. HSet 3 shows the mean fracture spacings of 55-57cm and the ratio of code 1 fractures is 15.4-26.9 percent. In spite of the mean fracture spacing of 239cm, code 1 fractures of HSet 4 have the highest ratio of 54.5 percent. From the fact that faults or open fractures have high hydraulic conductivity, it can be inferred that the three fracture sets of N55-85$^{\circ}$E/50-80$^{\circ}$SE, N20-60$^{\circ}$W/50-75$^{\circ}$NE and N10-30$^{\circ}$E/$\leq$30$^{\circ}$NW from a fracture system of relatively high conductivity. It is indirectly verified with geophysical loggings and constant injection tests performed in the boreholes.

  • PDF

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF

The Role of Camera-Based Coincidence Positron Emission Tomography in Nodal Staging of Non-Small Cell Lung Cancer (비소세포폐암의 림프절 병기 결정에서 Coincidence PET의 역할)

  • Lee, Sun-Min;Choi, Young-Hwa;Oh, Yoon-Jung;Cheong, Seong-Cheoll;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong;Park, Chan-H;Hahn, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.642-649
    • /
    • 1999
  • Background: It is very important to determine an accurate staging of the non-small cell lung cancer(NSCLC) for an assessment of operability and it's prognosis. However, it is difficult to evaluate tumor involvement of mediastinal lymph nodes accurately utilizing noninvasive imaging modalities. PET is one of the sensitive and specific imaging modality. Unfortunately PET is limited use because of prohibitive cost involved with it's operation. Recently hybrid SPECT/PET(single photon emission computed tomography/positron emission tomography) camera based PET imaging was introduced with relatively low cost. We evaluated the usefulness of coincidence detection(CoDe) PET in the detection of metastasis to the mediastinal lymph nodes in patients with NSCLC. Methods: Twenty one patients with NSCLC were evaluated by CT or MRI and they were considered operable. CoDe PET was performed in all 21 patients prior to surgery. Tomographic slices of axial, coronal and sagittal planes were visually analysed. At surgery, mediastinal lymph nodes were removed and histological diagnosis was performed. CoDe PET findings were correlated with histological findings. Results: Twenty of 21 primary tumor masses were detected by the CoDe PET. Thirteen of 21 patients was correctly diagnosed mediastinal lymph node metastasis by the CoDe PET. Pathological N0 was 14 cases and the specificity of N0 of CoDe PET was 64.3%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N1 node was 83.3%, 73.3%, 55.6%, 91.7%, and 76.2% respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N2 node was 60.0%, 87.5%, 60.0%,87.5%, and 90.0% respectively. There were 3 false negative cases but the size of the 3 nodes were less than 1cm. The size of true positive nodes were 1.1cm, 1.0cm, 0.5cm respectively. There were 1 false positive among the 12 lymph nodes which were larger than 1cm. False positive cases consisted of 1 tuberculosis case, 1 pneumoconiosis case and 1 anthracosis case. Conclusion: CoDe PET has relatively high negative predictive value in the enlarged lymph node in staging of mediastinal nodes in patients with NSCLC. Therefore CoDe PET is useful in ruling out metastasis of enlarged N3 nodes. However, further study is needed including more number of patients in the future.

  • PDF

Postoperative Radiotherapy in the Rectal Cancers Patterns of Care Study for the Years of $1998\~1999$ (직장암의 방사선치료에 대한 Patterns of Care Study: $1998{\sim}1999$년도 수술 후 방사선치료 환자들의 특성 및 치료내용에 대한 분석결과)

  • Kim, Jong-Hoon;Oh, Do-Hoon;Kang, Ki-Moon;Kim, Woo-Cheol;Kim, Won-Dong;Kim, Jung, Soo;Kim, June-Sang;Kim, Jin-Hee;Kil, Hak-Jae;Suh, Chang-Ok;Sohn, Seung-Chang;Ahn, Yong-Chan;Yang, Dae-Sik
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.22-31
    • /
    • 2005
  • Purpose : To conduct a nationwide survey on the principals in radiotherapy for rectal cancer, and produce a database of Korean Patterns of Care Study. Materials and Methods : We developed web-based Patterns of Care Study system and a national survey was conducted using random sampling based on power allocation methods. Eligible patients were who had postoperative radiotherapy for rectal cancer without gross residual tumor after surgical resection and without previous history of other cancer and radiotherapy to pelvis. Data of patients were Inputted to the web based PCS system by each investigators in 19 institutions. Results : Informations on 309 patients with rectal cancer who received radiotherapy between 1998 and 1999 were collected. Male to female ratio was 59 : 41, and the most common location of tumor was lower rectum ($46\%$). Preoperative CEA was checked in $79\%$ of cases and its value was higher than 6 ng/ml in $32\%$. Pathologic stage were I in $1.5\%$, II in $32\%$, III in $53\%$, and IV in $1.6\%$. Low anterior resection was the most common type of surgery and complete resection was peformed in $95\%$ of cases. Distal resection margin was less than 2 cm in $30\%$, and number of lymph node dissected was less than 12 in $31\%$. Chemotherapy was peformed in $91\%$ and most common regimen was 5-FU and leucovorine ($59\%$). The most common type of field arrangement used for the initial pelvic field was the four field box (Posterior-Right-Left) technique ($65.0\%$), and there was no AP-PA parallel opposing field used. Patient position was prone in $81.2\%$, and the boost field was used in $61.8\%$. To displace bowel outward, pressure modulating devices or bladder filling was used in $40.1\%$. Radiation dose was prescribed to isocenter in $45.3\%$ and to isodose line in 123 cases ($39.8\%$). Percent delivered dose over $90\%$ was achieved in $92.9\%$. Conclusion : We could find the Patterns of Care for the radiotherapy in Korean rectal cancer patients was similar to that of US national survey. The type of surgery and the regimen of chemotherapy were variable according to institutions and the variations of radiation dose and field arrangement were within acceptable range.