• Title/Summary/Keyword: 초음파 응용

Search Result 356, Processing Time 0.023 seconds

Interactive image segmentation for ultrasound vascular imaging (초음파 혈관 영상의 상호적 영상 분할)

  • Lee, Onseok;Kim, Mingi;Ha, Seunghan
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.4
    • /
    • pp.15-21
    • /
    • 2012
  • Image segmentation for object to extract data from ultrasound acquired is an essential preprocessing step for the effective diagnosis. Various image segmentation methods have been studied. In this study, interactive image segmentation method by graph cut algorithm is proposed to develop a variety of applications of vascular ultrasound imaging and diagnostics. General imaging and vascular ultrasound imaging segmentation by entering constrain condition such as foreground and background. In the future it will be able to develop new ultrasound diagnostics.

Optimal Design of Micro-Positioning Actuator by using Three-dimensional Finite Element Analysis and Evolution Strategy (3차원 유한요소법과 진화전략 알고리즘을 적용한 마이크로 포지셔닝 액추에이터의 형상 최적설계)

  • Oh, Kwang-Il;Rho, Jong-Seok;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.65-67
    • /
    • 2006
  • 압전현상을 응용하여 설계, 제작되는 기존의 초음파 모터는 기계적인 구조가 단순하여 설계가 비교적 용이한 장점을 갖추고 있는 반면, 그 해석에 있어서는 전통적일 수치해석적인 방법을 사용하고 trial-and-error에만 의존하는 설계 방식으로 인하여 과학적으로 최적화된 설계가 이루어지지 않음으로써 초음파 모터의 효과적인 설계가 이루어지지 않는 문제점이 존재 하였다. 따라서 본 연구에서는 3차원 유한요소법과 확률론적 최적화 기법인 진화전략 알고리즘을 이용하여 초음파 모터의 설계에 대한 최적화 기법을 제시하고 제시된 최적화 기법을 이용하여 소형 초음파 모터 중 Micro-Positioning Actuator(MPA)의 설계 및 해석을 수행하여 그 타당성을 검증하였다.

  • PDF

Numerical Analysis of Piezoelectric Element for Ultrasonic Joinning (초음파 접합용 진동자 냉각에 관한 수치해석)

  • Park, Sang-Jun;Lee, Young-Lim
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.398-401
    • /
    • 2011
  • 초음파의 응용분야에는 음파 성질을 이용한 정보 측정분야와 에너지를 이용한 용접 및 가공 등을 들수 있다. 초음파 용접의 경우 저항용접이나 용융 용접을 적용할 수 없는 재료의 접합에 이용되는데 이는 모재를 음극간에 놓고 압입하면서 초음파를 발신하여 그 진동을 이용하는 용접방법이다. 압전소자의 경우 피에조 물질을 사용하는데 일반적으로 $150^{\circ}C$이상에서 분자구조의 변형을 일으켜 제 역할을 못하게 된다. 본 연구에서는 압전소자와 공구혼의 온도를 최적으로 유지하기 위하여 추가적인 공기 유로와 방열핀을 설계하여 이것이 방열성능에 미치는 영향에 대해 고찰하였다.

  • PDF

Pattern Recognition Improvement of an Ultrasonic Sensor System Using Neuro-Fuzzy Signal Processing (초음파센서 시스템의 패턴인식 개선을 위한 뉴로퍼지 신호처리)

  • 나승유;박민상;임승우
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.03a
    • /
    • pp.95-98
    • /
    • 1998
  • 초음파센서는 저렴성, 단순한 구조, 기계적 강인성, 사용상의 적은 제약 등의 이점 때문에 다양한 응용분야에 적용된다. 물체의 인식에 초음파센서를 사용하기에는 낮은 분해능을 초래하는 불량한 방향성과 측정오류를 유발하는 반사성의 어려움을 내재하고 있다. 이런 문제를 개선하기 위해서 다양한 센사의 배열형태에서 많은 수의 센서를 사용하거나, 일정 수의 센서를 사용할 경우에는 센서의 배열을 기계적으로 이동시킨다. 본 논문에서는 물체의 패턴인식에 있어서 가장 기본적인 거리, 물체크기, 물체각도 값을 얻기 위해 간단하게 구성된 전자회로를 부가하여 초음파센서의 송출전압을 여러 단계로 변경시켜 얻어낸 데이터에 뉴로퍼지 기반의 지능적 계산 알고리즘을 적용하여 개선된 결과를 얻는다.

  • PDF

Control Method of Omni-directional piezoelectric actuator (전방향성 액추에이터를 위한 제어 방법)

  • Jung, Woo-Suk;Kang, Chong-Yun;Kim, Jeong-Do;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.50-50
    • /
    • 2008
  • 본 연구에서는 전방항성 초음파 액추에이터의 제작, 시뮬레이션, 구동 드라이버 제작, 제어 방법에 대하여 연구하였다. 우선, 시뮬레이션 툴인 ATILA를 사용하여 전방향성 초음파 액추에이터를 설계하였고 구동 주파수, 어드미턴스 특성 그리고 액추에이터의 움직임을 분석하여 최적의 구동 주파수 영역을 파악하였다. 실제 구동을 확인하기 위하여 액추에이터 스테이지와 구동 드라이버를 개발 하였다. 전방항성 액추에이터 스테이지의 구조는 액추에이터와 4개의 볼 베어링이 알루미나 볼을 압착하는 형태이며 세라믹에 인가되는 사인파의 위상차에 의하여 4개의 방향으로 구동 할 수 있다. 또한, 액추에이터를 위치 제어를 위하여 로터리 엔코더 두 개를 사용하여 구의 움직임을 파악하였고 PID 제어기법을 사용하여 액추에이터의 움직임을 제어하였다. 스테이지 구조상 엔코더의 $70^{\circ}$ 내에서만 구동 가능하며, 실험 결과를 통하여 전방향성 초음파 액추에이터는 약 $1.2^{\circ}$의 분해능을 가지고 구동영역 내 원하는 좌표로의 이동이 가능했고, 향후 고 정밀 관절 및 인공 눈에 응용 가능할 것으로 사료된다.

  • PDF

Modal Analysis of an Ultrasonic Tool Horn for RFID TAG Micro-pattern Forming (RFID TAG 미세패턴 성형을 위한 공구혼 진동해석)

  • Kim, Kang-Eun;Lee, Bong-Gu;Choi, Sung-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.652-658
    • /
    • 2016
  • In this paper, the theoretical research and simulation using the Finite Element Method (FEM) to design and form a micro-pattern for an ultrasonic horn is described. The present method is based on an initial design estimate obtained by FEM analysis. The natural and resonant frequencies required for the ultrasonic tool horn used for forming the fine pattern were predicted by finite element analysis. FEM analysis using ANSYS S/W was used to predict the resonant frequency for the optimum technical design of the ultrasonic horn vibration mode shape. When electrical power is supplied to the ultrasonic transducer, it is converted into mechanical movement energy, leading to vibration. The RFID TAG becomes the pattern formed on the insulating sheet by using the longitudinal vibration energy of the ultrasonic tool horn. The FEM analysis result is then incorporated into the optimal design and manufacturing of the ultrasonic tool horn.

Non-contact Ultrasonic Technique for the Evaluation Wall Thinning of the Plate (박판의 두께감육 평가를 위한 비접촉 유도초음파 검사 기법)

  • Park, Ik-Keun;Kim, Hyun-Mook;Kim, Tae-Hyung;Kim, Yong-Kwon;Cho, Yong-Sang;Song, Won-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.287-293
    • /
    • 2005
  • Ultrasonic guided waves are gaining increasing attention for the inspection of platelike and rodlike structures. At the same time, inspection methods that do not require contact with the test piece are being developed for advanced applications. This paper capitalizes on recent advances in the areas of guided wave ultrasonics and noncontact ultrasonics to demonstrate a superior method for the nondestructive detection of defects thinning simulating hidden corrosion in thin aluminum plates. The proposed approach uses EMAT(electro-magnetic acoustic transducer) for the noncontact generation and detection of guided waves. Interesting features in the dispersive behavior of selected guided modes are used for the detection of plate thinning. It is shown that mode cutoff measurements provide a qualitative detection of defects thinning. Measurement of the mode group velocity can be also used to quantify depth thinning.

Ultrasonic Approach of Rayleigh Pitch-catch Contact Ultrasound Waves on CFRP Laminated Composites

  • Yang, In-Young;Im, Kwang-Hee;Heo, Uk;Hsu, David K.;Sim, Jae-Ki;Kim, Hak-Joon;Song, Sung-Jin
    • Journal of Korea Foundry Society
    • /
    • v.27 no.5
    • /
    • pp.209-211
    • /
    • 2007
  • 최근에는 탄소섬유강화복합재료(CFRP)는 우수한 기계적인 물성치와 수월한 설계특성으로 인해 우주.민간 항공산업분야 뿐만 아니라 여러분야에 응용성이 매우 높다. 그러나 CFRP 복합적층판으로 제작된 구조물은 충격손상을 받을 시에는 50-75%치 강도가 낮아지는 취약성을 가지고 있다. 따라서 본 연구에는 CFRP복합재의 구조건전성 및 결함여부를 비파괴적으로 검사 및 탐상을 하기 위해서 시도하였다. 특히, C-scanner의 수침조에서 충격손상을 받은 시험편을 집어넣어 자동 데이터 획득 시스템을 구동하여 현장응용성이 가장 높은 일 방향 초음파측정 (one-sided ultrasonic measurement) 방법인 평가기법을 제안하였다. 본 연구에서 제안한 일방향 초음파 피치캐치방법이 CFRP 복합적층판내에서 일반 수직 초음파 탐상기법보다 훨씬 민감함을 알 수 있었다.

A study on the Electrical Characteristics of piezoelectric Ceramics Used In Ultrasonic Trasmitting Sensor by Ba Substitution (Ba 치환에 의한 초음파 송신기용 압전 소자의 전기적 특성에 관한 연구)

  • 조봉희;최창규;박창규;박상만
    • Electrical & Electronic Materials
    • /
    • v.3 no.1
    • /
    • pp.20-28
    • /
    • 1990
  • Pb(Zr, Ti)O$_{3}$-Pb(Ni, Nb)O$_{3}$계 세라믹스에 Ba를 치완시켜 Ba치환량의 증가에 따른 유전율, 전기기계결합계수 및 압전 d정수의 변화를 고찰하였다. 또한 Ba치환에 따른 세라믹스 소자의 송신감도 특성을 조사하고 큐리온도 이동에 따른 온도안정성을 고려하여 초음파 송신기용 압전소자에 응용가능함을 보였다.

  • PDF

초음파 영상 진단의 원리 및 응용

  • 최종수
    • 전기의세계
    • /
    • v.34 no.9
    • /
    • pp.541-547
    • /
    • 1985
  • 생체내부의 영상진단법 중에 진단시 인체에 무해, 무통하며 실시간 동적 영상을 제공해주는 치명적인 잇점을 갖고 있는 초음파영상 진단장치는 그 내부를 살펴보면 타 의용장치와는 달리 전기.전자공학의 결정체이다. 그러나 X선 CT에 비해 화질이 멀어지고 정량성 결여의 문제점을 안고 있다. 그러나, 소형, 저렴성은 그 이용도를 높혀주고 있으나 화질불량은 화상진단시 숙련을 요구하고 확실한 정보 제공의 장벽이 되고 있다. 따라서 상기의 문제점을 해결하기 위한 노력의 일환이 Tissue Characteization이다.

  • PDF