• Title/Summary/Keyword: 초음파 위해성

Search Result 559, Processing Time 0.027 seconds

A Study on the Cross Talk Level in a Piezoelectric Ultrasonic Array Transducer (압전형 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • 이수성;김영신;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.56-61
    • /
    • 2002
  • In piezoelectric ultrasonic linear array transducers widely used for diagnosis, the cross talk caused by the structural cross-coupling between adjacent elements inside the transducer affects the probe performance in a significant manner. In this study, we constructed a finite element model of a piezoelectric ultrasonic transducer, and analyzed its cross talk level with respect to the shape of and materials inside the kerf, The results of this work can be utilized in optimal design of the transducers for medical diagonosis and treatment as well as W applications.

Experimental Studies on Ultrasonic Guided Waves for the On-Line Inspection of Structural Integrity of Nuclear Power Plants (원전 기기 건전성의 온라인 검사를 위한 유도 초음파의 실험적 연구)

  • Eom, Heung-Seop;Kim, Jae-Hee;Song, Sung-Jin;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • Deployment of an advanced on-line monitoring of the component integrity offers a prospect of improved performance, enhanced safety, and reduced overall cost for nuclear power plants. Ultrasonic guided waves have been known as one of the promising techniques that could be utilized for on-line monitoring. The present work is aimed at developing a new method for on-line monitoring of the pipes during the operation period of nuclear power plants. For this purpose, the steam generator (S/G) tube was selected as an object of tile experiment. Dispersion corves and the incident angles corresponding to the specific modes were calculated for the S/G tube. The modes of guided waves were identified by the time-frequency diagrams obtained by the short time Fourier transform. It was experimentally confirmed that there was no mode conversion when the ultrasonic guided waves passed over the curved region of the S/G tube. An optimum mode of guided wave for the S/G tube was suggested and verified by the experiment.

Transvaginal Ultrasound-Guided Biopsy (경질 초음파 유도생검)

  • Su Hyeok Lim;Jung Jae Park;Chan Kyo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1233-1243
    • /
    • 2023
  • Percutaneous ultrasound-guided biopsy is useful for the pathologic confirmation of variable body lesions to establish diagnostic and therapeutic approaches. However, deep pelvic lesions are a challenge for pathologic diagnoses because of the presence of the bowel, bladder, major vessels, and pelvic bones which make a percutaneous approach difficult and dangerous. In female, the vagina is elastic and near the pelvic internal organs. Therefore, transvaginal ultrasound may serve as an effective and safe guide for the pathologic diagnosis of pelvis lesions. This review aimed to introduce the indications for, and the method of transvaginal ultrasoundguided biopsy, and to describe the reported diagnostic accuracy and safety.

Correlation Analysis of Signal to Noise Ratio (SNR) and Suspended Sediment Concentration (SSC) in Laboratory Conditions (실험수로에서 신호대잡음비와 부유사농도의 상관관계 분석)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.775-786
    • /
    • 2017
  • Monitoring sediment flux is crucial especially for maintaining river systems to understand morphological behaviors. Recently, hydroacoustic backscatter (or SNR) as a surrogate to empirically estimate suspended sediment concentration has been increasingly highlighted for more efficient acquisition of sediment dataset, which is difficult throughout direct sediment sampling. However, relevant contemporary researches have focused on wide range solution applicable for large natural rivers where H-ADCPs with relatively low acoustic frequency have been widely utilized to seamlessly measure streamflow discharge. In this regard, this study aimed at investigating hydroacoustical characteristics based on a very recently released H-ADCP (SonTek SL-3000) with high acoustic frequency of 3 MHz in order to capitalize its capacity to be applied for suspended sediment monitoring in laboratory conditions. SL-3000 was tested in a laboratory flume to collect SNR in conjunction with LISST-100X for actual sediment concentration and particle distribution in both sand and silt sediment injection in various amount. Conventional algorithms to correct signal attenuations for water and sediment were carefully tested to validate whether they can be applied for SL-3000. As result of analyzing the SNR-SSC correlation trand, through further study in the future, it is confirmed that SSC can be observed indirectly by using the SNR.

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Precision Measurement of Ultrasonic Power the Milliwatt Range (밀리와트 영역의 초음파 파워 정밀 측정)

  • Jho, Moon-Jae;Hwang, Cheol-Ho;Suh, Sang-Joon;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.25-33
    • /
    • 1990
  • An ultrasonic power measurement system in milliwatt range was constructed. The ultrasonic power can be determined by measuring the radiation pressure on a target using self-compensating microbalance. Measurement was performed using a perfect reflector and a perfect absorber. In order to check the feasibility of the system, the ultrasonic power for the two targets was measured. Also, the systematic measurement errors and the reproducibility were examined. The relative error between two targets is proved to be within 2%. Also when the ultrasonic power range is larger than 10mW, the standard deviation for repeated measurement becomes smaller than ${\pm}$2%.

  • PDF

Popliteal Arterial Compression Caused by Osteochondroma: Usefulness of Doppler Ultrasonography (골연골종에 의한 슬와동맥 압박: 도플러 초음파의 유용성)

  • Jeong, Woong-Kyo;Kim, Ho-Joong;Lee, Soon-Hyuck
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.69-73
    • /
    • 2010
  • Osteochondroma arising around the knee joint may sometimes be associated with vascular complication. Angiography is widely used to demonstrate the vascular complication, but it is invasive. Recently MR angiography is recommended as a non-invasive alternative, but it is very costly. We report a twenty-year-old man with popliteal arterial compression caused by osteochondroma who was diagnosed and assessed the surgical result by Doppler ultrasonography. And we also provide the usefulness of Doppler ultrasonography.

  • PDF

Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves (초음파를 이용한 에폭시 몰드변압기의 열화 진단)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 1999
  • Measurements of ultrasonic signals caused by partial discharges were perlonnrl by using an ultrasonic measurement technique to diagnose the electrical treeing deterioration in an epoxy mold-type power transformer. We also examined the characteristics of tree growth, partial discharge magnitude and ultrasonic pulse number with the increase of the deterioration time. From these results, it was found that the shape of the tree was a branch-type, and the rates of the tree growth were examined when ac voltages of 16[kV] and 20[kV] were applied Ultrasonic pulse number and discharge magnitude were rapidly increased as the length of the tree grows after the middle stage of the deterioration time, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, time-delaying and directivity characteristics of ultrasonic signals propagated into epoxy resin by using ultrasonic oscillation and receiving systems are also re[prted as a basic data of ultrasonic mesasurements in mold-type power transformer.former.

  • PDF

The Use and Findings of Ultrasound in the Elbow Joint (주관절의 초음파 소견 및 이용)

  • Bae, Jung Yun;Lee, Seung-Jun;Lee, Kun Woo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.94-100
    • /
    • 2013
  • Musculoskeletal ultrasound has unique advantages that may be free from exposure to radiation, low price compared to MRI, outpatient procedure that can be easily accessible, and better accuracy combined with physical examination. Dynamic ultrasound performed with stress tests are known to be useful for detecting the hidden lesions in the tendons, ligaments, nerves. Ultrasound in the elbow can be used easily in the outpatient for evaluation of the joint surface and synovial space; diagnosis for tendon diseases such as lateral epicondylitis, medial epicondylitis and morbidity of peripheral nerves; guide for anterior-posterior bursal and intra-articular injections.

  • PDF

Extraction and Analysis of Muscular Area from Ultrasound Images Using ART2-based Quantization (ART2 기반 양자화를 이용한 초음파 영상에서의 근육 영역 추출 및 분석)

  • Kim, Jin-Ho;Lee, Hae-Jung;Kim, Kwang-Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.398-403
    • /
    • 2007
  • 초음파 영상은 미세한 명암도 차이 등에 의해 분석 과정에서 근육 영역의 위치와 크기를 판단하는데 어려움이 발생하고 이로 인해 근육 영역을 파악하는데 주관성이 개입된다. 본 논문에서는 근육영역을 객관적으로 분석하기 위해 ART2 신경망을 적용하여 양자화를 수행한 후, 국부적 영역에서 근육 영역을 추출한다. 초음파 영상에서 히스토그램 평활화와 엔드인 탐색 알고리즘을 적용하여 명암도의 분포와 밝기 값을 보정 한 후, ART2 신경망을 이용하여 유사한 영역을 클러스터링 한다. 그리고 클러스터링 된 각 영역의 크기, 위치 및 명암도 정보를 분석하여 피하지방, 근육 막, 기타 배경 영역으로 분류한다. 최종적인 근육 영역을 찾기 위해 근육 막 내부 객체들 간의 거리, 각도를 이용하여 근육 막 영역에 둘러싸인 근육 영역을 추출한다. 실제 초음파 영상을 대상으로 실험한 결과, 일반적인 클러스터링 기법을 적용한 방법 보다 ART2 기반 양자화와 제안된 영역 확장 기법으로 근육영역을 추출하고 분석하는 것이 효율적임을 확인하였다.

  • PDF