• Title/Summary/Keyword: 초음파 속도측정

Search Result 357, Processing Time 0.022 seconds

Sewage sludge solubilization using ultrasonic combined with calcium peroxide (초음파/과산화칼슘(US/CaO2)을 이용한 하수슬러지 가용화)

  • Han, Jun-Hyuk;Nam, Se-Yong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.41-46
    • /
    • 2021
  • In order to investigate the degree of sewage sludge solubilizaion using ultrasonic(US) combined with calcium peroxide(CaO2), VSS reduction rate, solubilization rate, SCOD/VSS ratio, SCOD increasing rate, LB-EPS(Loosely-Bound EPS) and TB-EPS(Tightly-bound EPS) were measured. US was compared as a control. Solubilization rate increased by 23.4% under US and increased by 50.7% under US/CaO2(0.05 g CaO2/g VSS). and also, at the same conditions, VSS reduction rate increased by 7.1% and 17.7%, respectively. SCOD increasing rate from 10 to 90 minutes was 0.0151 min-1 under US/CaO2(0.02 g CaO2/g VSS). TB-EPS decreased by 36.4% under US and decreased by 59.0% under US/CaO2(0.05 g CaO2/g VSS). TB-EPS decreased during first 10 minutes and then decreased slowly until 90 minutes. There was no significant difference in TB-EPS decrease according to the dosage of calcium peroxide.

Fabrication of anti-reflection thin film by using sol-gel hybrid solution (Sol-gel 하이브리드 용액을 이용한 반사방지막 제조)

  • Park, Jong-Guk;Lee, Ji-Sun;Lee, Mi-Jai;Lee, Young Jin;Jeon, Dae-Woo;Kim, Jin-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.6
    • /
    • pp.220-224
    • /
    • 2016
  • Anti-reflection (AR) thin films were fabricated on a glass substrate by using an ultrasonic spray. Glycidoxypropyl trimethoxysilane (GPTMS) and tetraethyl orthosilicate (TEOS) were used to synthesize a sol-gel hybrid coating solution. The moving speed of spray nozzle was changed from 15~25 mm/s to control the coating thickness of AR thin film. As the moving speed of spray nozzle increased, the thickness of AR thin film decreased from 138 nm to 86 nm. When the AR thin film was fabricated by nozzle moving speed of 20 mm/s, the refractive index and thickness of AR thin film was measured to be 1.31 and 104 nm, respectively. The average reflectance and transmittance of AR thin film coating glass was measured to be 0.75 % and 94 %, respectively into the visible light range of 380~780 nm.

Effects of Inspiratory Muscle Training on Diaphragm Thickness, Pulmonary Function, and Chest Expansion in Chronic Stroke Patients (흡기근 저항훈련이 만성 뇌졸중 환자의 횡격막 두께와 폐기능에 미치는 효과)

  • Jung, Ju-Hyeon;Kim, Nan-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.1
    • /
    • pp.59-69
    • /
    • 2013
  • 연구목적: 본 연구는 만성 뇌졸중 환자를 대상으로 흡기근 저항훈련이 횡격막 두께와 폐기능 및 흉곽 확장에 미치는 효과를 알아보고자 수행하였다. 연구방법: 연구 대상자는 총 29명(남자 17명, 여자 12명)으로 흡기근 저항훈련군(15명)과 대조군(14명)으로 분류하였다. 모든 대상자는 6개월 이상된 만성 뇌졸중 환자로 일반적인 신경발달치료를 받고 있으며, 같은 기간 동안 흡기근 저항훈련군에 역치부하 흡기근육 단련기(threshold IMT device)를 제공하고 주 3회${\times}$1회 20분씩 6주간 시행하였다. 마비측과 비마비측 횡격막 두께측정을 위해 초음파의 7.5MHz linear probe를 사용하여 최대 흡기시(Tdi.con)와 휴식시(Tdi.rel)의 두께를 측정하고 수축률(TR)을 계산하였다. 또한 폐 활량계를 사용하여 노력성 폐활량을 측정하였으며, 줄자를 사용하여 흉곽 확장을 측정하였다. 연구결과: 6주간 중재 후 흡기근 저항훈련군에서 최대흡기시 횡격막 두께(Tdi.con)와 수축률(TR)은 유의한 증가를 보였다(p<.05). 1초간 노력성 호기량 ($FEV_1$)과 최대 호기 속도(PEF)도 유의한 증가를 보였으나(p<.05), 노력성 폐활량(FVC)과 1초간 노력성 호기량의 노력성 폐활량에 대한 비($FEV_1$/FVC), 흉곽 확장은 유의한 증가는 보이지 않았다(p>.05). 결론: 본 연구는 만성뇌졸중 환자를 대상으로 흡기근 저항훈련의 적용이 횡격막의 수축력과 폐기능 및 흉곽 확장력을 향상시켜 호흡근의 협응력을 증가시키고, 비활동성으로 인해 감소된 운동내성을 증가하게 함으로써 향후 재활에서 만성 뇌졸중 환자에게 2차적인 기능향상에 도움을 줄수 있을 것으로 보여진다.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF

Influence of Surface Treatment of SiO$_2$ and Stirring Rate on Fragrant Oil Release Behavior of Poly($\varepsilon$-caprolactone) Microcapsules (실리카의 표면 처리와 교반 속도가 폴리카프로락톤 마이크로캡슐의 향유 방출 거동에 미치는 영향)

  • 박수진;양영준;이재락;서동학
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.464-469
    • /
    • 2003
  • In this work, the fragrant oil release behavior of poly($\varepsilon$-caprolactone) (PCL) microcapsules containing SiO$_2$ was investigated. The SiO$_2$ was chemically treated in 10, 20, and 30 wt% hydrochloric acid and sodium hydroxide. The acid and base values were determined by Boehm's titration technique and $N_2$/77 K adsorption isotherm characteristics, the specific surface area and total pore volume were studied by BET. The PCL microcapsules containing SiO$_2$ and fragrant oil were prepared by oil-in-water (o/w) emulsion solvent evaporation method. The shape and surface of PCL microcapsules were observed using image analyzer and scanning electron microscope (SEM). The fragrant oil release behavior of PCL microcapsules was characterized using UV/vis. spectra. The average diameters of PCL microcapsules were decreased from 35 to 21 $\mu$m with increasing stirring rate. It was found that in the case of acidic treatment the fragrant oil adsorption capacity and release rate were increased due to the increase of specific surface area and acid value. In the case of basic treatment, the fragrant oil adsorption capacity and release rate were decreased due to the decrease of sp ecific surface area and the increase of acid-base interactions between SiO$_2$-NaOH and fragrant oil with increasing base value of SiO$_2$.

The Study of Aliasing and Incidence Angle Dependence of Doppler Image on Humeral Artery (상완동맥 Doppler 영상의 입사각 의존성과 Aliasing에 관한 연구)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.379-387
    • /
    • 2008
  • Among methods to eliminate aliasing effects, the method of increasing velocity scale gradually eliminated the phenomenon in which the direction of the blood flow appeared in reverse. It was done by increasing the velocity scale while maintaining other parameters in the same state. The method of setting the Doppler angle to $0^{\circ}$ did not show significant changes in the wave pattern of the spectrum according to the angle. In actual ultrasonography tests, more accurate tests are expected to be carried out by applying variations to the velocity scale under the considerations of speed, accuracy, and convenience of the examination. The results showed that blood flow velocity increases exponentially according to the Doppler Angle. When the angle goes over $70^{\circ}$, the velocity value increases to an unmeasurable state. This indicates that in blood flow velocity measurements, the blood flow velocity is very dependent on the Doppler Angle. It also shows that the error increases when the incidence angle to the direction of blood flow exceeds $60^{\circ}$, and when the angle exceeds $70^{\circ}$, the error becomes even greater. In addition, he experiment results showed that an angle below $60^{\circ}$ is appropriate and for blood flow velocity measurements in extremity vessels, the most appropriate Doppler Angle is from $45^{\circ}$ to $60^{\circ}$.

  • PDF

Improvement of Current Velocity Estimation Method in an ADCP (ADCP에서의 유속 추정 방법 개선에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1818-1825
    • /
    • 2017
  • An Acoustic Doppler Current Profiler(ADCP) measures the current velocity and analyzes the degree of turbulence using Doppler effects of ultrasonic waves. Therefore, the autocorrelation or FFT spectrum estimates are obtained for extraction of current velocity in each spatial region. However, if the correlation method does not satisfy the assumption that the return signal spectra are symmetric Gaussian, the large bias errors can occur. Also, the accurate estimation of autocorrelation or FFT spectrum is difficult due to the short acquisition interval when the rapid changes of current velocity occur. Thus, in this paper, the estimation method of the autoregressive spectrum peak is suggested for the accurate current velocity measurement of both symmetric and asymmetric spectra. It is shown that estimation quality can be improved using the suggested method comparing with the conventional methods. Many return signals under the various environment are simulated and the results are compared and analyzed for evaluation of the suggested method.

Effect of Vanadium Addition on the Cavitation Erosion Resistance of Fe-Cr-Ni-Si-C Hardfacing Alloy (Fe-Cr-Ni-Si-C계 경면처리 합금의 Cavitation Erosion 저항성에 미치는 Vanadium 첨가의 영향)

  • 김경오;김준기;장세기;김선진;강성군
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.72-72
    • /
    • 1998
  • 원자력발전소 1차계통내 밸브의 경면처리(hardfa따1잉에 사용되는 재료는 $90~343^{\circ}C$의 고온과 높은 접촉응력 그리고 급격한 압력변화가 일어나는 환경에서 사용되기 때문에 내마모성과 내식성 그리고 cavitation erosion 저항성이 우수한 Co계 Stellite 합금이 현재 사용되어진다. 그러나 Co가 원력발전소 1차계통의 방사선장을 형성하는 주요 원소로 알려지면서 S Stellite 합금을 대체할 수 있는 Fe계 경면처리용 합금을 개발하려는 연구가 진행되고 있다. 현재 Fe계 경면처리용 합금의 개발은 적절환 팝금원소를 첨가하여 적충결함에너지를 낮춤 으로써 전위의 교차슬립을 억제하여 표면을 경화시키고, 소성변형을 억제하여 마모저항성을 향상시키려는 방법으로 연구가 진행되고 있다. 본 연구에서는 Fe-Cr-Ni-Si-C 합금에 Fe계 합금의 적충결함에너지를 감소시키는 것으로 알려진 vanadium을 0, 1, 2wt%첨가하여 첨가량의 변화가 cavitation erosion 저항성에 미치 는 영향을 조사하였다. Cavitation erosion 실험은 초음파를 이용하여 미세한 기포를 발생시키는 vibratory type으로 A ASTM G-32 규격에 따라 제작된 실험장치를 이용하여 $25{\pm}2^{\circ}C$의 온도의 증류수 속에 잠긴 상태에서 실시하였다. 시면은 지름 16mm, 두게 7mm의 버턴형태로 vanadium 첨가량을 변화시킨 조성을 아크 용융 방법을 이용하여 제작하였으며 hom끝단부에 부착하여 cavitation e erosion 저항성 살험을 하였다. 시편의 cavitation erosion 실험시간에 따른 무게감소량을 측 정하였으며 cavitation erosion 시킨 시편의 표면을 SEM으로 관찰하였다.겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$

  • PDF

Performance Analysis of Scalar Adaptive Filter for Formation Flying (정렬비행을 위한 적응 스칼라 필터의 성능 분석)

  • Lim, Jun-Kyu;Park, Chan-Gook;Lee, Dal-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.5
    • /
    • pp.455-461
    • /
    • 2008
  • In this paper, the performance of a scalar filter and a scalar adaptive filter are analyzed. In order to make indoor experimental environment similar to outdoor test, ultrasonic sensors are used instead of GPS. The scalar adaptive filter, which is continuously estimating velocity error covariance and measurement noise covariance by using adaptive method, is different from the scalar filter. Experimental results show that the scalar adaptive filter has better position estimating performance than the scalar filter by estimating above two parameters with an adaptive method.

Accomplishments of Rayleigh's Experimental Research: Improvement of Instruments and Enhancement of Precision (레일리의 실험 음향학 연구의 성과: 도구의 개선과 정밀성의 증진)

  • 구자현
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.113-120
    • /
    • 2003
  • Rayleigh was an excellent experimenter as well as a theorist. Rayleigh improved Rijke's sounding device by heat and the singing flame into sources of pure tones. Above all, his making of the artificial bird whistle was a critical achievement in the improvement of experimental sound sources. This source made supersonic waves available in the laboratory and thus paved the way to confirmable observations of reflection, refraction, diffraction and interference of sound in the laboratory Furthermore, Rayleigh augmented the sensitivity of sensitive flames as detectors for sound wave. Besides, he devised a phonic wheel which could precisely control the angular velocity of some acoustical instruments and made the Rayleigh-disk that enabled experimenters to measure the absolute value of the sound intensity. These devices enhanced the exactness of acoustical experiments.