• Title/Summary/Keyword: 초음파 감쇠

Search Result 163, Processing Time 0.028 seconds

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Thermal Dispersion Method for a Medical Ultrasonic Phased Array Transducer (의료용 초음파 위상배열 트랜스듀서의 열 분산 방안)

  • Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.210-218
    • /
    • 2015
  • When the driving voltage of an ultrasound transducer is increased to improve the quality of ultrasound images, heat is generated inside the transducer that can cause patient's skin burn and degradation of transducer performance. Hence, in this paper, a method to disperse the heat of the transducer has been studied. The phased array transducer having 3 MHz center frequency and 32 channels was selected for analyses of the thermal dispersion. First, mechanism of the heat generation was investigated in relation to the transducer operation through theoretical analysis, and material damping and sound pressure amplitude were confirmed to be influential on the heat generation. Further, we investigated the effects of the properties of the materials constituting the transducer on the thermal dispersion through finite element analysis. Based on the analysis results, we determined the thermal properties of the constituent materials that could facilitate the thermal dispersion inside the transducer. The determined thermal properties were applied to the finite element model, and the results showed that the maximum temperature at an acoustic lens contacting with a patient was decreased to 51 % of its initial value.

A Theoretical Study on Interface Characteristics of SiC Particulate Reinforced Metal Matrix Composite Using Ultrasonics (초음파를 이용한 입자강화 금속복합재료의 계면특성에 관한 이론적 연구)

  • Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.4
    • /
    • pp.9-17
    • /
    • 1994
  • It is well recognized recently that ultrasonic technique is one of the most widely used methods of nondestructive evaluation to characterize material properties of nonconventional engineering materials. Therefore it is very important to understand physical phenomenon on propagation behavior of elastic wave in these materials, which is directly associated with ultrasonic signals in the test. In this study, the theoretical analysis on multi-scattering of harmonic elastic wave due to the particulate with interface between matrix and fiber in metal matrix composites(MMCs) was done on the basis of Lax's quasi-crystalline approximation and extinction theorem. SiC particulate (SiCp) reinforced A16061-T6 composite material was chosen for this analysis. From this analysis, frequency dependences of phase velocity and amplitude attenuation of effective plane wave due to the change of volume fraction of SiC particulate were clearly found. It was also shown that the interface condition between matrix and fiber in MMCs gives a direct effect on the variation of phase velocity of plane wave in MMCs.

  • PDF

Acoustic Properties of Ultrasonic Transducer Using Piezocomposites (압전복합재료를 이용한 초음파 트랜스듀서의 음향 특성)

  • Lee, Sang-Wook;Ryu, Jeong-Tag;Nam, Hyo-Duk;Kim, Yeon-Bo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.80-86
    • /
    • 2007
  • We have investigated on the development of 2-2 type piezocomposites that have better piezoelectric activity and lower acoustic impedance than those of conventional piezoceramics. In this study, we have investigated the piezoelectric and acoustic properties of 2-2 type piezocomposites sensor which was fabricated using dice-and-fill technique for the different volume fraction of PZT. The specific acoustic impedance of 2-2 type piezocomposites decreased linearly when PZT volume fraction was decreased. The resonance characteristics measured by an impedance analyzer(HP4194A) were similar to the analysis of finite element method (FEM). The resonance characteristics and the electromechanical coupling factor were the best when the volume fraction PZT was 0.6. It also showed the highest result from the standpoint of sensitivity, bandwidth and ring-down property and so on at the same condition. The specific characteristics show that the 2-2 type piezocomposites turned out to be superior to the ultrasonic sensor composed by single phase PZT.

The Interaction Between Stress Waves in Elastic Solids for an Ultrasonic Viscometer and Adjacent Viscous Fluids (초음파 점도계용 고체 매질의 탄성파와 인접 점성유체 간의 상호작용)

  • 김진오
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.28-34
    • /
    • 1999
  • The effects of the viscosity of an adjacent viscous fluid on the characteristics of the elastic waves have been studied theoretically and experimentally. Expressions for the wave speed and attenuation of the elastic waves of transverse motion, such as the torsional wave propagating in a circular cylinder and the Love wave in a layered half-space solid, have been obtained as functions of the viscosity and mass density of the fluid by exact and asymptotic analyses. The theoretical results have been compared with experimental observations, and it has been demonstrated that a device described herein can be used as a sensor for measuring the viscosity of a fluid with a known mass density.

  • PDF

Measurement Ultrasound Attenuation by Using Phase Spectral Difference Method (위상 스펙트럴 차분법에 의한 초음파 감쇠 계수의 측정)

  • Min, Yong-Ki;Choi, Jong-Ho;Lee, Kang-Ho;Choi, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1243-1246
    • /
    • 1987
  • To characterize the biological tissues, the new methods to measure the frequency dependent attenuation are presented in this paper. In general, ultrasonic phase information was assumed by linear function of the frequency. But, the minimum phase function which characterizes the frequency dispersion of tissue was derived in [l]. It is very significant to measure the attenuation by using the minimum phase function to characterize the frequency dispersion of tissue. Therefore, a more efficient method measuring the frequency dependent attenuation are proposed by using the estimated sound velocity and polarity of reflected signal. To verify the algorithms, pulse reflection experiments are performed.

  • PDF

Development of Medical Ultrasound Imaging Techniques for Tissue Characterization (The Correction Method of Diffraction Effect in Measurements of Attenuation Coefficient) (조직 정량화를 위한 의용 초음파 영상 기술 개발(감쇠계수 측정에서 회질 영향의 보정법))

  • 한성현;이강호;최종호;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1925-1932
    • /
    • 1990
  • In this paper, we consider the effect of diffraction due to the finite-sized aperture and propose the new correction method of errors in measurements of attenuation coefficient owing to the diffraction effect. In the existing correction method, we obtained the attenuation coefficient after correct the spectrum at each depth. However, this paper obtain the attenuation coefficient using lg-spectral difference approach and then correct errors. As a proposed method is not correction for the spectrum at each depth but the difference spectrum, we reduce the calculation. Also the correction is performed through the total frequency range, the accurate attenuation coefficient in whole bandwidth is produced.

  • PDF

Development of Medical Ultrasound Imaging Techniques for Tissue Characterization (Attenuation Effect on Measurement and Tomography of Nonlinear Parameter) (조직 정량화를 위한 의용 초음파 영상 기술 개발(비선형 파라미터의 측정 및 단층영상에 미치는 감쇠의 영향))

  • 이현주;이강호;최종호;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1916-1924
    • /
    • 1990
  • In this paper attenuation effect on the measurement and the tomography of nonlinear parameter is discussed. We perform computer simulation with the method using harmonic components and the method using secondary wave components, and then estimate attenuation effect through the results and compare two measurement techniques. According to simulation result the attenuation effect is more intensive as large n and \ulcorner, and the degree of the attenuation effect is represented as error functions. In the aspect of measuremnet techniques, the method using secondary wave components is more insensitive to attenuation effect than the method using harmonic compnents. We obtain the same result in the nonlinear tomography, and show that the attenuation compensive filter is required because the whole tomogram is affected by frequency dependent attenuation(or nonlinear attenuation)

  • PDF

Study on the ultrasonic attenuation and false indications of austenitic stainless sleet Steel weldment (스테인레스강(鋼) 용접부(熔接部)의 초음파감쇠(超音波減衰) 및 거짓신호(信號)에 관(關)한 연구(硏究))

  • Kang, Suk-Chull;Lee, Yun-Peel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.3 no.1
    • /
    • pp.19-25
    • /
    • 1983
  • Some studies have been made on the effects of the attenuation on the result of ultrasonic examination of austenitic stainless steel weldment and also on the cause of false indications. The differences in the amplitudes and the metal paths of the ultrasonic examinations have been measured experimentally, for two kinds of waves, one passed through only the parent material and the other one through the weldment. The effect of probe angles and frequency on the examination data have been investigated using the shear wave. It has been found that the false indications were caused by back reflection from the weld metal surface due to the characteristics of ultrasonic wave propagation. It has been confirmed that the probe of $2.25\;MHz\;and\;60^{\circ}$ is the best choice in the ultrasonic examination and that the correction of amplitude for attenuations is necessary.

  • PDF

The Mechanical Properties and the Nondestructive Evaluation of Dissimilar Friction Welded Steel Bars (이종마찰용접 강봉재의 기계적특성과 비파괴 평가)

  • Jung, W.T.;Kong, Y.S.;Kim, S.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2006
  • In this study, dissimilar friction welding were produced using 15mm diameter solid bar in chrome molybedenum steel(SCM440) to carbon steel(S45C) to investigate their mechanical properties and the relationship between the weld parameters and the nondestructive coefficients, such as AE counts and ultrasonic attenuation coefficient. The main friction welding parameters were selected to endure good quality welds on the basis of visual examination, tensile tests, Vickers hardness surveys of the bond of area and heat affected zone. The specimens were tested as-welded and post weld heat treated(PWHT). The tensile strength of the friction welded steel bars was increased up to 100% of the S45C base metal under the condition of all heating time. The ductility of PWHT specimens is higher than as-welded.

  • PDF