• Title/Summary/Keyword: 초음파유량계

Search Result 108, Processing Time 0.033 seconds

Korean Institute of Ceramic Eng. & Tech. (수도계량기용 초음파 유량센서의 설계 및 평가)

  • Lee, Young-Jin;Paik, Jong-Hoo;Jeong, Young-Hun;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.364-364
    • /
    • 2008
  • 유한요소해석을 통하여 수도계량기용 삽입형 초음파 유량계 압전 트랜스듀서의 설계를 실시하고 이를 평가하였다. 상용 해석프로그램인 PzFlex를 사용하여 센서의 transient 해석을 실시하였다. 이를 통해 각 구성부품의 재질 및 형상 변수를 결정하였다. 이를 기준으로 트랜스듀서를 제작하였으며, 두께모드 중심주파수가 1.2MHz가 되도록 직경 10mm의 압전소자를 이용하였다. 시뮬레이션을 통해 $25^{\circ}$의 방사각으로 음향파가 발생되도록 트랜스듀서를 설계, 제작한 후, 트랜스듀서의 전기적, 기계적 특성을 평가하였다.

  • PDF

Flowrate Integration Errors of Multi-path Ultrasonic Flowmeter using Weighting Factors (가중계수에 의한 다회선 초음파 유량계의 유량적분오차)

  • Lee, Ho-June;Hwang, Shang-Yoon;Kim, Kyoung-Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.154-160
    • /
    • 2003
  • Multi-path ultrasonic flowrate measuring technology is being received much attentions from a variety of industrial fields to exactly measure the flowmeter. Multi-path ultrasonic flowmeter has much advantage since it has no moving parts and not occurred pressure loss. It offers good accuracy, repeatability, linearity and Tum-down ratio can measure over 1:50. The present study investigates flowrate integration errors using weighting factors. A theoretical flow model uses power law to describe a fully developed velocity profiles and wall roughness changes. The methods of weighting factor simulate three configurations of measuring location of gaussian, chebyshev and tailor method. The obtained results show that many chord arrangements are not affected for wall roughness changes and can measure accurate flowrate.

  • PDF

Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves (밸브 하류에 설치된 건식 초음파유량계의 편차특성)

  • Lee, Dong-Keun;Cho, Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

A Study on the Improvement of Characteristics of the Ultrasonic Transducer Used in Flowmeter (초음파 유량계에 사용되는 초음파 진동자 특성향상에 관한 연구)

  • Hyun, Byung-Gook;Hwang, Shang-Yoon;Ahn, Yong-Kwan;Park, Sung-Ha
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.394-399
    • /
    • 2001
  • For the piezoelectric vibrator, PZT, in a general transmit-receive sensor using the ultrasonic flowmeter, the characteristics of frequency response relating to the backing materials were analyzed with the Mason equivalent circuit for design and the sensitivity of fabricated transducer relating to the matching materials was measured and discussed. The results those were measured in water for the transmit-receive characteristics of each transducer can be applied to the flowmeter sensor.

  • PDF

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

Development of an ultrasonic velocity profiler by using pulse repetition frequency method (펄스반복주파수 기법을 이용한 초음파 유속 프로파일러 개발)

  • Lee, Chan-Joo;Kim, Dong-Gu;Kwon, Sung-Il;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1921-1925
    • /
    • 2010
  • 개수로의 흐름을 측정하는 유속계는 유체역학 및 수리학적 연구와 유량 측정 등의 업무에 필수적인 장비이다. 그동안 국내에서는 일부 전자파표면유속계(이상호 등, 1997)와 영상처리 기반의 LSPIV(김영근 등, 2004)와 같은 비접촉식 유속측정 장치가 개발되어 활용되고 있지만, 유속 및 유량 측정에 보다 널리 사용되고 있는 수중 투입식 유속계의 경우 거의 개발되지 않았다. 특히 유속 분포를 측정하는데 활용될 수 있는 초음파 방식 유속 프로파일러는 거의 전적으로 외국제품에 의존하고 있다. 일반 유속계가 점유속을 측정하는데 비해 유속 프로파일러는 센서가 지향하는 방향선을 따라 공간적인 유속분포를 동시에 획득할 수 있으므로 측정 효율성이 높다는 장점을 지닌다. 본 연구에서는 국내 기술로 개수로 흐름 측정에 활용할 수 있는 초음파 유속 프로파일러를 개발하였다. 이 유속 프로파일러는 초음파 펄스를 반복적으로 송수신하는 PRF 기법을 이용하여 개발하였다. 개발된 유속 프로파일러는 직사각형 수로에서 유속 분포를 측정하기 위해 적용하였으며, 기존의 2차원 유속계와 그 결과를 비교하였다. 본 연구에서 개발한 유속 프로파일러는 실제 하천에 활용하기에는 측정 가능한 유속 및 수심 범위의 한계가 있으나 PRF 기법의 한계 범위에서는 실측 유속분포를 비교적 잘 재현하는 것으로 나타났다.

  • PDF

A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter (습식 다회선 초음파유량계의 특성평가 연구)

  • Lee, Dong-Keun;Cho, Yong;Ko, Jae-Myoung;Park, Tae-Jin;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

Correlation Analysis of Flow Characteristics Downstream of a Double Bent Pipe and Mounting Positions of Ultrasonic Flowmeter (곡관하류의 유동특성과 초음파유량계 설치위치의 상관관계 분석)

  • Lee, Dong Keun;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1037-1046
    • /
    • 2013
  • In this study, the establishment of the criteria for accurate measurement is investigated via a statistical analysis of experimental results. The magnitude of influence on measurement errors is severely affected by the number of paths, mounting angle of sensor, straight pipe length in sequence, and Reynolds number. Three-dimensional numerical analysis has been conducted to understand the flow patterns downstream of a double bent pipe. Numerical analysis shows that the results well agreed with the experimental ones in case of a sensor mounting angle of $0^{\circ}$ and L/D = 3, 5 of $45^{\circ}$, $135^{\circ}$ in a single path. As a result, when the Reynolds number is 700,000-1,400,000, the sensor error of a single-path ultrasonic flowmeter is reduced with the mounting condition of L/D = 3, $45^{\circ}$.