• Title/Summary/Keyword: 초음파법

Search Result 1,180, Processing Time 0.027 seconds

Ultrasonic Measurement in Bovine Serum Albumin Solution (Bovine Serum Albumin 수용액의 초음파 측정)

  • Jong-Rim Bae;Seung Hyun Chang
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.329-334
    • /
    • 1992
  • Ultrasonic absorption was measured in bovine serum albumin (BSA) aqueous solution (50 g/l) in the frequency range from 100 kHz to 1600 MHz at neutral pH. Three experimental techniques were used to cover the wide frequency range : plano-concave resonator, conventional Bragg reflection, and high-resolution Bragg reflection methods. The absorption spectrum at neutral pH fitted the relaxation curve well using the distribution function of a mirror image of Davidson-Cole function. The relaxaition behavior was interpreted in terms of various degree of hydration of BSA molecules.

  • PDF

Extraction of lipoma Using ART2 from Ultrasonic Images (초음파 영상에서 ART2를 이용한 지방종 추출)

  • Lim, Hyo-Bin;Kim, Kwang Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.507-509
    • /
    • 2015
  • 본 논문에서는 지방종 초음파 영상에서 지방종을 자동적으로 추출하는 방법을 제안한다. 제안된 방법은 초음파 영상에 Monotone Cubic Spline 보간법을 이용하여 ROI영역을 추출한다. 추출된 ROI 영역에 Fuzzy Stretching 기법을 적용하여 명암 대비를 강조한 후, ART2 알고리즘과 8방향 윤곽선 추적 알고리즘을 적용하여 잡음을 제거한 후에 지방종의 후보 영역을 추출한다. 추출된 지방종의 후보 영역 중에서 형태학적으로 타원 형태를 띠거나 가장 큰 후보 영역의 정보를 이용하여 Labeling 기법을 적용하여 최종적으로 지방종 영역을 추출한다. 제안된 방법을 지방종 초음파 영상에 실험한 결과, 지방종 영역이 비교적 정확히 추출되는 것을 실험을 통하여 확인하였다.

  • PDF

Correlations between Acoustic Properties and Bone Mineral Density in Bovine Femoral Trabecular Bone In Vitro (생체 외 조건의 소 대퇴골 해면질골에서 음향특성과 골밀도 사이의 상관관계)

  • Hwang, Kyo-Seung;Seo, Dong-Wan;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.244-252
    • /
    • 2012
  • The purpose of the present study is to investigate the correlations between acoustic properties, such as speed of sound and normalized broadband ultrasound attenuation, and bone mineral density in femur with high fracture risk. The speed of sound and the normalized broadband ultrasound attenuation in 15 bovine femoral trabecular bone samples in vitro were measured by using a through-transmission method with two matched pairs of ultrasonic transducers with center frequencies of 0.5 and 1.0 MHz. The volumetric bone mineral density of the trabecular bone samples was measured by using micro-computed tomography. The bone mineral density exhibited strong correlations with both the speed of sound and the normalized broadband ultrasound attenuation measured by using the 0.5 and the 1.0 MHz transducers. The highest correlation was found between the bone mineral density and the normalized broadband ultrasound attenuation measured by using the 0.5 MHz ultrasonic transducers. The results suggest that the acoustic properties measured in the femur in vitro can be used as indices for the prediction of femoral bone mineral density.

A Study on the Ultrasonic Relaxation of Axial-Equatorial Isomerization in Methylcyclohexane (Methylcyclohexane의 초음파 완화현상의 연구)

  • 배종림;김정구
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.3-7
    • /
    • 1998
  • Methylcyclohexane의 초음파 흡수측정을 0.1-2MHz의 주파수 범위, 온도 30-60℃에 걸쳐 1MHz이하에서 정확한 초음파 흡수측정이 가능한 광 회절 초음파 공명법을 사용하여 행하였다. 그 결과, axial과 equatorial에 의한 완화는 단일 완화현상을 보였고 그 스펙트럼 으로부터 완화 주파수와 완화강도를 결정하였다. 완화 주파수의 온도 의존성으로부터 활성 화에너지(△H*)=10.0㎉/㏖을, 완화 강도의 온도 의존성에서 엔탈피 차(△H)=1.8㎉/㏖을 각각 구하였다.

  • PDF

Optimization of Antioxidant Extraction from Dandelion (Taraxacum officinale) Leaves Using BBD-RSM (BBD-RSM을 이용한 민들레로부터 항산화성분의 추출공정 최적화)

  • Han, Kyongho;Jang, Hyun Sik;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.408-414
    • /
    • 2019
  • In this study, an antioxidant was extracted from dandelion leaves using traditional hot water and ultrasonic extraction methods. In order to optimize the extraction yield and total flavonoid, an antioxidant, Box-Behnken design (BBD) model among response surface analysis methods was used. In the case of hot water extraction, the extraction temperature and time as well as the ratio of alcohol/ultrapure water were set as variables, and for the ultrasonic extraction, the ultrasonic survey century and irradiation time and the ratio of alcohol/ultrapure water were variables. Optimum extraction conditions in the hot water extraction method were the extraction temperature and time of $45.76^{\circ}C$ and 1.75 h and the ratio of alcohol/ultrapure water of 41.92 vol.%. While for the ultrasonic extraction method the survey century of 512.63 W, the ratio of alcohol/ultrapure water of 56.97 vol.% and the extraction time of 20.79 min were optimum conditions. Expected reaction yield and flavonoid content values under the optimized condition were calculated as 22.09 wt.% and 28.98 mg QE/mL dw, respectively. In addition, the error value of less than 3% was obtained validating our optimization process.

Measurement of Elastic Constants of Thin Metallic Foil by Guided Wave Dispersion Characteristics (유도초음파 분산 특성을 이용한 박판의 탄성계수 측정)

  • Lee, Dong-Jin;Cho, Youn-Ho;Jang, Kang-Won;Cho, Seung-Hyun;Ahn, Bong-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • As the development of MEMS/NEMS structure and application technology the demand for an assessment of the mechanical properties have increased. The mechanical properties are mainly evaluated by using tensile test or ultrasonic wave measurement. However, the new technology have been developed such as nano-indentation, guided wave method because they have a limitation in case of a thin plate and thin film. In the study, the guided wave velocities are measured by electromagnetic-acoustic transducer(EMAT), the material properties of thin metallic foils are obtained using optimization process of the theoretical and experimental group velocity of guided wave. The Young's modulus obtained by the optimization process(201.6 GPa), nano-indentation(207.0 GPa) and literature value(203.7 GPa) of a $50{\mu}m$ thick nickel thin plate shows good agreement within 3%.

Implementation of Ultrasonic Immersion Technique for Babbitt Metal Debonding in Turbine Bearing (초음파 수침법을 이용한 터빈베어링 Babbitt금속 박리 검사 기술)

  • Jung, Gye-Jo;Park, Sang-Ki;Cho, Yong-Sang;Park, Byung-Cheol;Kil, Doo-Song
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.348-353
    • /
    • 2004
  • This study is aimed for the implementation of ultrasonic method to assess the reliability of turbine bearings. A modified ultrasonic immersion technique was carried out in both laboratory experiment and field application. From the laboratory results, we confirmed that the condition of interface layer between the babbitt and base metal be monitored by the C-Scan. The C-scan image by the ultrasonic immersion test can be used successfully to observe the condition of interface layer. The testing with a focused transducer provides a promising approach for estimating the extent of the damaged region and observing the interface layer effectively. The difference of the ultrasonic reflection ratio between the bonding and debonding area at the interface layer is one of the key parameters for assessing the extent of the damaged area; additionally, the reflection amplitude exhibits a favorable correlation with the overall damage level. The technique developed in this study was applied to the inspection of the turbine bearings at several power plants in Korea whereby the applicability in the field can be ascertained.

Filtration of dispersed nanoparticles using cyclone and ultrasonic atomization (초음파 무화 및 사이클론을 이용한 분산된 나노입자의 여과법)

  • Jung, Jihee;Kim, Moojoon;Kim, Jungsoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • In order to overcome the limitation of conventional nanoparticle dispersion methods such as sonicator or homogenizer, a filtration method using an ultrasonic atomization effect and cyclones was proposed in this study. A 0.5 wt% suspension was made with Al2O3 powder with an average diameter of 250 nm. The suspension was filtered by the proposed method after pre-dispersing using a sonicator and a homogenizer, respectively. As the result, in the case of the suspension after pre-dispersing with a sonicator, the particle size distribution of the filtered suspension started showing up a single normal distribution indicating the mode of the average diameter only after the 3rd cyclone process. On the other hand, in the case of the suspension with the homogenizer pre-dispersion, similar results appeared from the 2nd cyclone process. Filtration of various types of nanoparticles is expected to be possible by adjusting ultrasonic atomization frequency and manipulating the design of the cyclone.

Development of 1-3 Piezocomposite Ultrasonic Transducers by means of the Finite Element Method (유한요소 해석법을 이용한 1-3형 압전복합체 초음파 트랜스듀서의 개발)

  • 이수성;김동현;한진호;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.274-281
    • /
    • 2004
  • In this study. a 1-3 piezo-composite single element ultrasonic transducer was designed with a commercial finite element analysis (FEA) code. PZf1ex and developed based on this design. Design with FEA could be performed overcoming many constraints of the typical theoretical method, and also was very practical. Validity of the design with the FEA was illustrated through experimental characterization of fabricated 1-3 piezo-composites and ultrasonic transducers, Through comparison with the result of the theoretical method. we confirmed the superiority of the design method using FEA.

Analysis of Kidney and Liver from Ultrasonography Images by Using Fuzzy Stretching and Monotone Cubic Spline (Fuzzy Stretching 기법과 Monotone Cubic Spline 보간법을 이용한 초음파 영상에서 간과 신장 영역 분석)

  • Lee, Dae-Woo;Lee, Min-Jung;Hong, Dong-Jin;Kim, Kwang Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.148-151
    • /
    • 2015
  • 초음파 검사를 이용한 지방간의 등급을 분류하는 진단 결과는 검사자의 주관적 판단으로 시행하므로 검사자 간의 불일치가 발생하여 초음파 검사의 진단 결과에 영향을 미칠 수 있다. 따라서 본 논문에서는 환자와 검사자에게 지방간 등급을 보다 정확하게 진단하기 위한 전단계로서 초음파 영상에서 간과 신장 영역을 추출하는 방법을 제안한다. 제안된 방법을 다양한 초음파 영상에 적용한 결과, 간과 신장 영역이 비교적 정확히 추출되는 것을 확인할 수 있었다. 따라서 제안된 방법이 초음파 영상에서 지방간을 분석하는데 적용할 수 있다.

  • PDF