• Title/Summary/Keyword: 초음파력

Search Result 230, Processing Time 0.024 seconds

Finite Element Analysis of a Particle Manipulation System Using Ultrasonic Standing Wave (정재초음파를 이용한 입자제어 시스템의 유한요소해석)

  • Cho, Seung-Hyun;Park, Jae-Ha;Ahn, Bong-Young;Kim, Ki-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.565-570
    • /
    • 2009
  • Micro particles in fluid can be manipulated by using ultrasonic standing wave since the ultrasound makes particles move by means of its acoustic radiation force. This work concerns the micro particle manipulation system using ultrasonic standing wave which consists of a microchannel, an adaptive layer, a reflector, and an ultrasonic transduer. In the present system, the effects of the structural elements should be carefully considered to comprehend the system and find the optimal operational condition. In this investigation, finite element analysis was employed to analyze the system. Some interesting characteristics on the reflector thickness, the channel width, and the operational frequency were observed. Several experimental results were compared with the analytic results. Consequently, this work solidifies the importance of those system parameters and reveals the possibility of various applications of the particle manipulation using ultrasonic standing wave.

  • PDF

Myxoid Liposarcoma of the Breast Mimicking Phyllodes Tumor: A Case Report (엽상종양과 유사한 유방의 점액성 지방육종: 증례 보고)

  • Se Jin Lee;Jung Kyu Ryu;Kyu Yeoun Won;Sang-Ah Han
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.952-957
    • /
    • 2023
  • Myxoid liposarcoma is an extremely rare malignant breast tumor. We report the case of a 44-year-old woman who had myxoid liposarcoma of the breast with a history of phyllodes tumor and describe the imaging findings on US, mammography, and MRI. Before surgery, the mass was considered to be a recurrent phyllodes tumor. However, using US, we retrospectively identified some differences between myxoid liposarcomas and phyllodes tumors.

Physicochemical Properties of Physically Modified Rice Starch by Homogenizer (균질기를 이용한 물리적 변성 쌀 전분의 이화학적 특성)

  • Han, Myung-Ryun;Kim, Myung-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.5
    • /
    • pp.700-706
    • /
    • 2005
  • The objectives of this research were to analyze physicochemical properties of physically modified rice starch which was prepared by hydro-shear homogenizer and ultrasonic homogenizer. The 5:1 of water to starch ratio, 20,500 rpm of hydro-shear homogenizer, and 5 sec of pulse and 40 kHz of frequency of ultrasonic homogenizer, which were operated for 10 min. The 1/3 of size reduction of raw rice starch and gelatinized rice starch, and reduced of particle size were achieved by above processing conditions. The homogenization of raw rice starch and gelatinized rice starch were higher values of specific area, transmittance, solubility and swelling power than control. While, these had lower value of apparent viscosity than control. In raw rice starch, the gelatinization characteristics of ultrasonic homogenizer treated rice starch had some higher values of gelatinization temperature, peak temperature and enthalpy than those of control. While, those of hydro-shear homogenizer treated rice starch had similar values to those of control.

Nano-Positioning of High-Power Ultrasonic Linear Motor Stage in High-Vacuum Environment (고진공 환경중 고출력 초음파 모터 이송 스테이지의 나노미터 위치 제어)

  • Kim, Wan-Soo;Lee, Dong-Jin;Lee, Sun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1613-1622
    • /
    • 2010
  • In this paper, the ultraprecision positioning control of an ultrasonic linear motor in a high-vacuum environment is presented. The bolt-clamped Langivin type transducer (BLT) with the 3rd longitudinal; and 6th lateral vibration modes was developed, which was excited by using the Eigen resonance frequency for two vibration modes in order to generate stable and high power. In practical applications, however, even if a geometrical design has an Eigen frequency, discordance between both mode frequencies can be generated by the contact mechanism and because of manufacturing errors as well as environmental factors. Both mode frequencies were precisely matched by adjusting the impedence. By using this method, the BLT can be driven under any environmental conditions. The nominal characteristic trajectory following(NCTF) control method was adopted to control the positioning of the system in vacuum. The developed linear motor stage show high positioning accuracy with 5 nm.

Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle (레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파)

  • Kwon, Sung-D.;Kwon, Yong-G.;Yoon, Seok-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • The angular dependence (or profile) of backscattered ultrasound was measured for steel specimens with a range of surface roughness, $1{\sim}71{\mu}m$. Backscattering profiles at or near the Rayleigh angle still showed roughness dependence while the assessment of surface roughness via normal profile became impossible due to the paint layer masking the roughness. The peak amplitude directly radiated at the Rayleigh angle was proportional to the surface roughness, while the averaged peak amplitude radiated from the backward propagating Rayleigh wave, produced by reflection at a corner, was inversely proportional. In the painted specimens, the linearity of direct backward radiation with the roughness was observed even at the roughness of less than three hundredths of a wavelength, and the abnormal multiple bark reflection caused by periodic roughness disappeared.

Thyroid Gland Evaluation of Adults in Their 20s by means of a Screening Ultrasound Test and a Self-Test (스크리닝 초음파검사와 자가진단에 의한 20대 성인의 갑상선 평가)

  • Ji, TaeJeong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.347-354
    • /
    • 2014
  • Korea Central Cancer Registry reported in 2011 that the prevalence rate of thyroid cancer was about 19.6% (the highest) in both men and women. The ratio of thyroid cancer, among cancers that women suffer from, was about 31.1%, the highest among female cancers and about five times more than men. Regarding the incidence of thyroid cancer by age group, the crude rate was highest in women and men aged 15~34. From these figures it can be inferred that there is a greater relationship between thyroid cancer and hormones compared with other cancers. Therefore, young women aged 20~25, even if they are in full health, should undergo a medical examination. This study is aimed at examining changes in thyroid gland detected through self evaluation tests and the analysis of ultrasound screening images in persons aged 20~25. According to the study, 213 persons (about 46.6%) out of 457 people who took part in the study had abnormal echo patterns. With regard to women's abnormal patterns, about 73.4% of them were found to have calcified cystic, 11.8% diffuse-type low-echo and 7.3% cystic echo. With regard to male participants, about 61.1% were found to have calcified cystic, followed by 19.4% with the size of the isthmus increased and 13.9% with diffuse-type low-echo. According to the outcomes of an analysis regarding self-testing for hyperthyroidism, the average points of participants who were found to have abnormal echo patterns in ultrasound tests were 6.85 and the figure was 5.88 in persons with normal patterns. The figure was about 15% higher in abnormal respondents.

Evaluation of Adhesive Strength for Nano-Structured Thin Film by Scanning Acoustic Microscope (초음파 현미경을 이용한 나노 박막의 접합 강도 평가)

  • Park, Tae-Sung;Kwak, Dong-Ryul;Park, Ik-Keun;Miyasaka, Chiaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.393-400
    • /
    • 2012
  • In recent years, nano-structured thin film systems are often applied in industries such as MEMS/NEMS device, optical coating, semiconductor or like this. Thin films are used for many and varied purpose to provide resistance to abrasion, erosion, corrosion, or high temperature oxidation and also to provide special magnetic or dielectric properties. Quite a number of articles to evaluate the characterization of thin film structure such as film density, film grain size, film elastic properties, and film/substrate interface condition were reported. Among them, the evaluation of film adhesive to substrate has been of great interest. In this study, we fabricated the polymeric thin film system with different adhesive conditions to evaluate the adhesive condition of the thin film. The nano-structured thin film system was fabricated by spin coating method. And then V(z) curve technique was applied to evaluate adhesive condition of the interface by measuring the surface acoustic wave(SAW) velocity by scanning acoustic microscope(SAM). Furthermore, a nano-scratch technique was applied to the systems to obtain correlations between the velocity of the SAW propagating within the system including the interface and the shear adhesive force. The results show a good correlation between the SAW velocities measured by acoustic spectroscope and the critical load measured by the nano-scratch test. Consequently, V(z) curve method showed potentials for characterizing the adhesive conditions at the interface by acoustic microscope.

Accelerating Effects of Ultrasonic Irradiation on Reaction Rates for the Asymmetric Ring Opening Reaction of Epoxides (초음파 조사에 의한 에폭사이드 비대칭 고리열림 반응의 속도 증진 효과)

  • Lee, Yae Won;Park, Geun Woo;Kim, Geon Joong
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.365-370
    • /
    • 2019
  • In this study, effects of the ultrasonic irradiation during the reaction process were investigated for the enantioselective kinetic resolution (EKR) reaction of racemic epoxides in the presence of chiral cobalt salen catalysts, as compared to that of using the conventional mechanical stirring. In order to compare catalytic activities, the chiral cobalt salen complexes having $AlCl_3-$, $BF_3-$ and nitrobenzenesulfonic acid (NBSA) were synthesized and used as catalysts, and then three kinds of the racemic epoxides such as ephichlorohydrine (ECH), epoxy phenoxypropane (EPP) and propylene oxide (PO) were used as reactants. In addition, EKR reactions have been performed using the water and methanol as nucleophiles, respectively. The unique contribution of ultrasonic irradiation as a powerful mixing medium was evaluated in this study to improve the kinetics in comparison to the conventional mechanical agitation during EKR reactions. The reaction time to obtain the highest 99 ee% became shorten more than that of above 60%, when the ultrasonic irradiation was used. This result may be interpreted by the cavitation effect of ultrasound in the solution, generating a powerful shear force for the very violent mixing.

Image enhancement in ultrasound passive cavitation imaging using centroid and flatness of received channel data (수신 채널 신호의 무게중심과 평탄도를 이용한 초음파 수동 공동 영상의 화질 개선)

  • Jeong, Mok Kun;Kwon, Sung Jae;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.450-458
    • /
    • 2019
  • Passive cavitation imaging method is used to observe the ultrasonic waves generated when a group of bubbles collapses. A problem with passive cavitation imaging is a low resolution and large side lobe levels. Since ultrasound signals generated by passive cavitation take the form of a pulse, the amplitude distribution of signals received across the receive channels varies depending on the direction of incidence. Both the centroid and flatness were calculated to determine weights at imaging points in order to discriminate between the main and side lobe signals from the signal amplitude distribution of the received channel data and to reduce the side lobe levels. The centroid quantifies how the channel data are distributed across the receive channel, and the flatness measures the variance of the channel data. We applied the centroid weight and the flatness to the passive cavitation image constructed using the delay-and-sum focusing and minimum variance beamforming methods to improve the image quality. Using computer simulation and experiment, we show that the application of weighting in delay-and-sum and minimum variance beamforming reduces side lobe levels.

A Clinical Study of Hypertrophic Pyloric Stenosis (비후성 유문 협착증의 임상적 고찰)

  • Kim, Yoon Hee;Jung, Myung Sup;Byun, Soon Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1389-1396
    • /
    • 2002
  • Purpose : This study was done to analyze the changes in the clinical conditions and the diagnosis of hypertrophic pyloric stenosis. Methods : We report a retrospective clinical analysis of 39 patients with hypertrophic pyloric stenosis from Jan. 1992 to Aug. 2001. The age and sex distribution, family and birth history, clinical symptoms, the ultrasonographic and the operative sizes of pyloric canals were compared. Results : The body weight was below the 3 percentile at admission in eight cases(20.5%). "Olive like mass" in right upper quadrant was palpated during physical examination in 23 cases(59%) and gastric peristaltic wave observed in six cases(15%). The ultrasonographic measurements showed that the pyloric muscle thickness to be $4.95{\pm}0.99mm$($mean{\pm}SD$), pyloric diameter $14.42{\pm}2.64mm$, and pyloric length $20.17{\pm}3.92mm$. Fredet-Ramstedt pyloromyotomy was employed in all cases. The operative measurements of the pyloric muscle thickness was $5.11{\pm}1.01mm$, pyloric diameter $15.01{\pm}2.47mm$, and pyloric length $22.32{\pm}3.43mm$. Conclusion : There was no significant difference between the ultrasonographic and operative measurements. Currently, the hypertrophic pyloric stenosis patients showed lesser clinical hallmarks of the disease. The earlier diagnosis using imaging studies before development of significant metabolic abnormalities is becoming an important factor that change the future outcomes of hypertrophic pyloric stenosis.