Search Result 20, Processing Time 0.026 seconds

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

Assessment of ADCP discharge measurement uncertainty by GUM framework through large scale experiment (실규모 실험을 통한 GUM 기반의 ADCP 유량 측정불확도 산정)

  • Kim, Jong Min;Kim, Dong Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.18-18
    • /
    • 2021
  • 초음파 도플러 유속계(ADCP)는 초음파를 이용하여 하천의 유속 및 수심을 측정하는 장비로 기존의 지점식 유속계와는 다르게 수심방향 유속분포와 수심을 한번에 측정하게 되며, 보트를 이용하여 하천을 횡단하게 되면 기존의 유속-면적법을 이용하는 방식보다 간편하고 빠르게 한 단면의 유량을 측정할 수 있다. 이와 같은 이점으로 인해 국내뿐만 아니라 해외에서도 대하천에서부터 중·소규모의 하천까지 다양한 범위에서 유량을 측정하는 장비로서 사용되어지고 있다. ADCP의 측정 유량은 유량관측소에서 수위-유량관계식을 구축할 때 사용하고 있으며, 이렇게 제공되는 유량은 하천의 중·장기 계획 수립, 수공구조물의 설계 및 수문·수리분야의 연구에 활용되고 있다. 하지만 ADCP의 유량측정은 ADCP의 미측정 영역의 유량 추정, ADCP 잠김깊이의 정확도, 하안에서의 고정 측정시간 등 ADCP의 측정 과정이나, 유량 추정 방법에 따라 영향을 받게 되며. 이외에도 하천의 수심, 하상의 상태와 같은 측정 조건에 따라서도 정확도의 변화가 발생할 수 있다. 측정결과의 정확성을 향상시키고, 신뢰도가 높은 자료를 제공하기 위해서는 ADCP의 유량 측정결과에 대한 불확도를 발생시키는 요인들에 대한 분석과 이를 감소시킬 수 있는 방법을 찾는 것이 중요하다. 1993년 ISO, BIPM, IFCC 등 6개 기구에서는 측정불확도를 산정하기 위한 측정불확도 산정 지침서(GUM, Guide to the expression of Uncertainty of Measurement)를 제시하였다. GUM 표준안은 측정과정에서 발생하는 다양한 불확도 요인들을 불확도 전파법칙을 통해 전체 불확도를 산정하는 방식으로 WMO와 ISO의 유량 측정분야에서도 GUM 표준안을 측정불확도 산정 기준으로 공인하여 사용하고 있다(JCGM 100, 2008; ISO 25377, 2020). 이에 본 연구에서는 GUM 표준안을 이용하여 ADCP로 측정된 유량의 측정불확도를 산정하는 방법을 개발하고 각 요인들에 대한 실험 및 분석을 진행하였다. ADCP의 측정 정확도를 분석하기 위한 실험은 자연에 가까운 형상을 모의하고 있고, 소하천 규모를 갖고 있는 하천연구센터에서 수행하였으며, 요인들에 대한 분석 방법 및 총 불확도를 계산하는 방법에 대하여 제시하였다.

  • PDF

Development of Real-time Automatic Discharge Acquisition & Remote-control System (실시간 자동유량관측 시스템 개발)

  • Kim, Chang-Wan;Lee, Min-Ho;Cheong, Sang-Hwa;Kim, Ki-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.551-555
    • /
    • 2007
  • 하구 감조부에서의 유량측정은 수문관측매뉴얼에 의하면 일반하천의 유량측정과 같은 원칙으로 실시하며, 일반 유량측정보다 신속하게 측정하고 유속과 유량을 연속적으로 측정해야 하고 조석을 잘 고려하여 관측계획을 수립하여야 하고 측정장비는 가급적 유향, 유속계의 기록부가 내장된 장비를 이용하도록 제안하고 있으며, 현실적으로 감조하천에서 유량측정은 많은 어려움이 따른다. 최근 우리나라에서 하천유량의 효율적인 측정을 위해 초음파유속계나 지표유속법과 같은 실시간 하천유량측정 방법이 도입되고 있다. 본 연구에서는 이러한 자동유량관측이 감조하천에 가능하도록 실시간 유량관측 시스템을 개발하여 운영하였다. 조석의 영향을 받는 한강대교지점에 도플러방식 초음파유량계를 회전체에 탑재한 자동유량측정장치를 남 북단 하천에 각각 1대씩 설치하였다. 본 시스템을 운영한 결과 무인 자동 연속 정밀관측이 가능하였으며, 1회 유속측정에 소요되는 $2{\sim}3$시간을 $5{\sim}6$분으로 단축시켰다. 이를 기반으로 감조하천에서의 자동유량관측이 가능하고 지표유속법을 도입하여 정확도를 높일 수 있는 유량산정기술을 개발하였다.

  • PDF

A study on the application validity of microwave water surface current meter for the measurement of river water intake (하천수 취수량 계측을 위한 전자파 표면 유속계의 적용 유효성 검토 연구)

  • Baek, Jong Seok;Kim, Chi Young;Cho, Sang Uk;Oh, Dong Heon;Kang, Hyun Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.347-347
    • /
    • 2020
  • 하천수의 통합적인 물관리를 위해서는 농업용수의 목적으로 취수되는 하천수량과 같은 기초자료의 확보가 필수적이다. 취입보를 통해 취수되는 하천수량은 취수문에 근접한 농업용수로에서 유량을 계측할 수 있는데, 계측지점의 특성에 맞는 최적의 계측방법 선정 및 검증이 필요하다. 대부분의 농업용수로는 단면이 일정하여 수위-유량 관계 곡선식, 초음파 측정법, 수면경사법, 구조물법 등 대부분의 계측방법 적용이 가능한데, 본 연구에서는 전자파 표면 유속계를 이용해 산정한 유량자료와 실측 유량자료와의 적합성을 비교하여 전자파로 측정한 유량자료의 정확도를 확인하였다. 전자파 표면 유속계는 도플러 효과를 이용해 표면 유속을 산정하는 방식으로, 주로 홍수기와 같이 고유량 상황에서 사용되고 있고, 저유량이나 바람이 센 상황에서는 표면유속이 단면 전체의 평균유속을 대변하기 어려워 연중 지속적인 활용도가 낮은 상황이다. 농업용수로는 다양한 규모로 설계되어 있어 저유량에서부터 고유량까지 넓은 범위의 계측방안이 필요한데, 전자파 표면 유속계를 이용한 계측으로는 연속적인 자료 확보에 한계가 있다. 본 연구에서는 일정한 단면에서 전자파 표면 유속계와 실측 유속과의 비교를 통해 적정 수준의 정확도를 가질 수 있는 전자파 표면 유속계 측정범위를 특정하고, 저유량 구간에서 취약한 표면 유속 측정 자료를 보정할 수 있는 개선 방법을 적용하여 농업용수를 취수하는 지점에서 전자파 표면 유속계의 연중 상시 계측 가능 방안에 대한 연구를 수행하였다. 전자파 표면 유속계의 측정 범위 특정과 저유량 계측 개선 방안 등을 통해 추후 농업용수로의 하천수 취수량 계측 방법 선정에 도움이 될 것으로 기대한다.

  • PDF

Operation and Verification of Real-time Discharge Measurement Using UVM in Large River (이동시간차 방식 자동유량측정시설의 대하천 운영 및 검증)

  • Rho, Young-Sin;Park, Hyun-Keun;Kim, Chi-Young;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.405-409
    • /
    • 2009
  • 현재 하천의 유량측정을 위해 국내외에서 설치, 운영되고 있는 자동유량측정시설은 대부분 초음파유속계를 이용한 실시간 하천유량측정시스템이다. 이러한 초음파유속계는 도플러 방식 초음파유속계(ADVM)와 이동 시간차 방식 초음파유속계(UVM)로 구분되는데, 한강대교 등에 적용된 ADVM 방식에 비해 UVM 방식은 초음파 도달거리의 특성으로 인해 대부분 중소규모의 하천에 적용되어왔다. 이러한 UVM 방식을 하폭이 넓고 홍수시 수위변화가 심한 대규모하천에 적용하기 위해서는 여러 회선을 다층으로 구성하여 설치할 필요가 있는데, 한강의 여주지점은 16개의 회선을 5개의 층으로 구성하여 측정의 정확도를 높이고 홍수시 수위상승시에도 다양한 회선으로 유속을 측정할 수 있도록 하였다. 본 연구에서는 여주지점에 설치되어 운영 중에 있는 이동 시간차 방식 자동유량측정시설의 운영결과를 검토하고 측정치에 대한 검증을 위해 2008년 1월부터 12월까지의 유량측정결과를 검토하였다. 평 저수시는 유속계와 ADCP 이동보트를 이용한 연속측정결과와 비교하였으며 홍수시에는 봉부자 측정결과와 비교하였다. 기존 실측은 2008년 2월부터 12월까지 저수위 및 중 고수위에 걸쳐 실시하였으며, 프라이스유속계 22회, 이동식 ADCP 6회 그리고 부자를 이용한 방법 6회등, 총 34회가 이루어졌으며, 비교 결과 수위 1.5m 이하의 저 평수기에 평균 5.5%의 오차를 보였으며, 홍수시 검증측정유량과의 비교결과 7.6%의 오차를 보였다.

  • PDF

Uncertainty Assesment for Moving-boat ADCP Discharge Measurements by GUM Framework (GUM 표준안 기반 이동식 ADCP 유량 측정 불확도 평가)

  • Kim, Dongsu;Kim, Jong Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.71-71
    • /
    • 2017
  • 하천에서 평수기 유량측정은 도섭법을 이용하기 위한 지점식 측정보다는 초음파 도플러 유속계(ADCP, Acoustic Doppler Current Profiler)를 보트에 탑재하여 운용하는 측정 방식이 점차 일반화되고 있다. ADCP는 초음파의 도플러효과를 이용하여 수심이나 횡방향의 유속 분포를 측정할 수 있는 측정 장비로 일반적으로 사용되는 down-looking ADCP는 수심방향의 유속분포와 수심을 측정하여 보트의 이동속도와의 벡터 내적을 이용하여 유량을 산정하게 된다. 그러나, 이동식 ADCP 유량 측정 성과의 불확도는 제공되지 않고 있는 상황인데, 이는 불확도 산정 표준안 미비, 유속 및 수심 등 측정 요소의 관측 환경 별 불확도 정보 부족, 불확도를 산정할 수 있는 툴의 부재 등에 기인한다. 본 연구에서는 이동식 ADCP 불확도 산정 표준안을 개발하고 현장 실험을 통해 불확도 요인에 대한 규명, 불확도를 편리하게 산정할 수 있는 툴을 개발하고자 하였다. 불확도 산정 표준안으로 최근 WMO를 위시한 국제적으로 하천 유량 측정 불확도 표준안으로 채택되고 있는 GUM(Guide to the Expression of Uncertainty Measurement)을 기반으로 이동식 ADCP 유량 산정 알고리즘을 적용하여 불확도 적용 기법을 개발하였다. GUM 표준안을 기반으로 유량 측정불확도를 산정하기 위한 불확도 요인분석은 실규모 하천의 특성을 대부분 모의할 수 있는 한국건설기술연구원의 안동하천실험센터에서 수행된 실험자료를 기반으로 다양한 인자들에 대한 요소 별 불확도 분석을 수행하였다. GUM 표준안에 의하면 불확도 요인들은 오차전파의 법칙에 기반하여 전체 불확도에 전파되며, 이렇게 합성된 불확도는 t-분포의 신뢰수준 95%일 경우의 보정계수 2를 곱하여 최종적으로 확장불확도를 산정하게 된다. 이동측정방식의 ADCP의 경우 GUM 표준안에 적용하여 불확도를 평가하기 위해서 사용되는 수식이 방대하고, 매우 복잡하기 때문에 이를 실무자가 평가하기에는 한계가 있다. 이에 따라 본 연구에서는 ADCP의 유량 측정불확도를 보다 편리하게 평가하기 위하여 ADCP 유량 측정불확도 평가 소프트웨어인 AQUA(ADCP Discharge Uncertainty Assesment)를 개발하였으며, 이를 통해 실무자나 연구자들이 ADCP의 불확도 평가에 보다 편리하게 접근할 수 있을 것이라 판단된다.

  • PDF

Correlation Analysis of Signal to Noise Ratio (SNR) and Suspended Sediment Concentration (SSC) in Laboratory Conditions (실험수로에서 신호대잡음비와 부유사농도의 상관관계 분석)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.775-786
    • /
    • 2017
  • Monitoring sediment flux is crucial especially for maintaining river systems to understand morphological behaviors. Recently, hydroacoustic backscatter (or SNR) as a surrogate to empirically estimate suspended sediment concentration has been increasingly highlighted for more efficient acquisition of sediment dataset, which is difficult throughout direct sediment sampling. However, relevant contemporary researches have focused on wide range solution applicable for large natural rivers where H-ADCPs with relatively low acoustic frequency have been widely utilized to seamlessly measure streamflow discharge. In this regard, this study aimed at investigating hydroacoustical characteristics based on a very recently released H-ADCP (SonTek SL-3000) with high acoustic frequency of 3 MHz in order to capitalize its capacity to be applied for suspended sediment monitoring in laboratory conditions. SL-3000 was tested in a laboratory flume to collect SNR in conjunction with LISST-100X for actual sediment concentration and particle distribution in both sand and silt sediment injection in various amount. Conventional algorithms to correct signal attenuations for water and sediment were carefully tested to validate whether they can be applied for SL-3000. As result of analyzing the SNR-SSC correlation trand, through further study in the future, it is confirmed that SSC can be observed indirectly by using the SNR.

Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel (사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토)

  • Son, Geunsoo;You, Hojun;Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1753-1764
    • /
    • 2014
  • Numerical flow simulation models in the riverine environments have been widely utilized for analyzing flow dynamics in various degrees in researches and practical applications. However, most of the simulated results have been validated based on the data from indoor experimental models or very limited in-situ measurements. Therefore, it has been required to more accurately validate the performance of the numerical models in terms of the detailed field observations. In particular, it was also hard to validate the performances of the existing numerical models in the real meandered river channels that encompass more sophisticated flow and geometric structures. Recently, advancements of the modern flow measuring instrumentations such as acoustic Doppler current profilers (ADCPs) enabled us to efficiently acquire the detailed flow field in the broad range of river channels, thus that it became to be possible to accurately validate any numerical models with the field observations. In this study, based on the detailed flow measurements in a actual meandered river channel using ADCP, we validated FaSTMECH model in iRIC in terms of water surface elevation, which is relatively new but began to get highlighted in the research areas. As the validation site, a meandering channel in River Experiment Center of KICT was chosen, which has 6.5 m of width, 0.38m of flow depth, 1.54 m3/s of flow discharge, 0.61 m/s of mean flow velocity, and 1.2 of sinuosity. As results, whereas the FaSTMECH precisely simulated water surface elevation, simulated velocity field in the bend did not match well with ADCP dataset.

Automatic Discharge Measurement Using the Velocity Index Method (유속지수법을 이용한 자동유량측정)

  • Kim, Chi-Young;Kim, Won;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.242-246
    • /
    • 2006
  • 최근 들어 전 세계적으로 유량측정 분야의 큰 변화의 방향은 자동화이다. 전자, 전기 기술과 정보통신 기술의 발달을 유량측정 분야에 적용하여 자동적으로 유량측정을 수행하고 실시간으로 모든 유량자료를 수집하는 시스템을 구성하려는 연구가 활발하게 진행중이다. 최근에 초음파 유량계와 더불어 자동 유량측정 기법으로 각광을 받고 있는 기법이 유속지수법(index velocity method)이다. 유속지수법의 원리는 매우 간단하다. 수위 기록을 통하여 수위-면적 관계로부터 흐름 단면적을 구하고, 임의의 영역에서 측정된 유속이 단면 평균 유속으로 환산될 수 있다면, 흐름 단면적과 평균 유속에 의해 연속적으로 유량을 구할 수 있다. 유속지수법에서 가장 중요한 것이 전체 평균 유속을 대표할 수 있는 유속지수를 정확하고 효율적으로 측정하는 것이다. 유속지수법에 의한 연속 유량측정 목적으로 최근에 ADVM(Acoustic Doppler Velocity Meter)이 개발되어 이용되고 있다. ADVM은 수중에 초음파를 발사해서 산란체에서 반사되어 돌아오는 초음파의 주파수 편이, 즉 도플러 효과를 이용하여 유속을 측정하는 유속계이다. 본 연구에서는 ADVM을 괴산댐 하류에 위치한 시험하천에 설치하여, 유속지수법에 의한 유량측정기법을 적용하고 그 특성을 분석하였다. 유속지수법으로 측정된 유량을 괴산댐 방류량과 비교한 결과 평균 4.0%의 상대오차를 지니고 있어 비교적 정확한 연속 유량측정이 가능한 것으로 나타났다. 이와 같은 유속지수법을 하천 유량측정에 활용하면 보다 정확한 유량을 연속적으로 자동화하여 측정할 수 있을 것으로 기대된다.연계모형의 한계로 인하여 두 모형의 통합모형이 필요하다. 즉, 강우 혹은 월류유량으로 발생한 지표유량 중 일부분이 과부하가 발생하지 않는 유입구 지점을 통과할 때 배수시스템으로 유입되는 것을 고려할 수 있고, 유입된 유량은 배수시스템 내의 흐름에 반영되도록 배수시스템과 침수해석모형을 통합한 모형 개발이 필요하다. 그러기 위해서는 지표면과 배수시스템에 대한 수리학적 관계를 정립하여야 한다. 본 연구에서는 배수시스템 해석 모형과 도시침수해석 모형을 통합하고, 두 모형간의 유량의 전송과정을 수리학적 관계를 고려한 dual-drainage 도시침수해석모형을 개발하였다. 이를 위해 도시지역 배수시스템 해석 모형으로 널리 이용되고 있는 SWMM모형을 이용하여 지표면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기

  • PDF

Automatic Flow Measurement by Acoustic Velocity Sensors on a Weir (기존 보와 유속센서를 활용한 자동유량측정)

  • Kim, Dong-Gu;Kim, Won;Lee, Chan-Joo;Kim, Chi-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.851-854
    • /
    • 2007
  • 기존 보를 활용하여 유량측정에 이용하는 방법은 보의 통제 특성을 이용한 것이다. 유량과 수위를 병행 측정하여 얻은 자료를 활용해 수위-유량관계를 개발하는 것이다. 이 방법은 간단하면서도 정확도가 높은 방법이다. 수위-유량관계가 개발되면 별도의 측정을 수행할 필요 없이 수위계 측정값으로 유량이 계산되기 때문이다. 물론 주기적인 수위-유량관계 검증은 반드시 필요하다. 이런 수위-유량관계를 이용한 기존 보 활용은 매우 유용한 방법 중 하나이다. 하지만 이런 기존 보를 활용해 유량을 계산하는 방법은 몇 가지 단점을 포함한다. 첫째, 통제 특성을 이용하는 모든 측정 구조물은 측정한계 조건이 있다. 즉, 보 마루에 한계류가 발생하지 않는 수위 이상으로 높아지면 보의 통제 특성이 소멸되고 수위-유량관계나 유량공식은 의미가 없어진다. 둘째, 유량측정 구조물의 가장 큰 문제점 중 하나가 토사퇴적이다. 특히 기존 보의 경우 토사가 퇴적되면 보 상류의 저류용량이 줄어 보의 통제 기능을 상실하게 된다. 이런 문제점들을 해결하기 위해 보마루를 높인다거나 정기적인 준설을 하는 방법이 있다. 장기적인 변화에 대응하는 것이지만 이런 조치는 임시방편일 뿐이다. 이런 문제를 해결하기 위해 연구하게 된 방법이 보마루에서 직접 유속측정을 하는 것이다. 그리하면 통제특성을 이용한 수위-유량관계가 필요 없게 된다. 이때 보마루에서 직접 유속측정을 하기 위해서 유속측정 센서를 이용한다. 유속측정센서는 도플러방식을 이용한 초음파 유속센서로써 uplooking 방식으로 보마루에 고정시켜 이용한다. 이런 센서는 관수로에서 유량을 측정하기 위해 많이 사용되고 있다. 본 연구를 위해 초음파 센서를 이용해 실험 수로에서 유속측정과 유량환산 결과를 비교해 보았고 실제 시험하천에서도 설치하여 적용해 보았다. 보마루라는 안정된 단면을 이용하여 유속을 직접 측정하는 방법은 앞서 언급했던 수위-유량관계를 이용한 기존 보 활용법상 단점도 극복할 수 있다. 즉 통제 특성과는 관계없이 측정할 수 있는 수심 범위에만 들어가게 되면 항상 측정이 가능하고 상류의 토사퇴적에도 영향을 전혀 받지 않는다. 설치한 후 센서가 파손되지 않고 관리만 잘 된다면 유량측정시 편리하고 정확하게 결과를 얻을 것으로 판단된다.

  • PDF