• Title/Summary/Keyword: 초음파건

Search Result 128, Processing Time 0.021 seconds

3-D Underwater Object Restoration Using Ultrasonic Sensor Fabricated with PZT-Polymer 3-3 Type Composite (PZT-고분자 3-3형 초음파 센서를 이용한 3차원 수중 물체 복원)

  • Cho, Hyun-Chul;Lee, Kee-Seong;Lee, Su-Ho;Kim, Han-Geun;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1373-1375
    • /
    • 1997
  • In this study, 3-D underwater object restoration using ultrasonic sensor fabricated with porous PZT-Polymer 3-3 type composite are presented Using the acquired underwater object data $16{\times}16$ pixels, Modified SCL neural networks using the $16{\times}16$ low resolution image was used for underwater object restoration of $32{\times}32$ high resolution image.

  • PDF

The Characteristics of an Ultrasonic Sprayer by using Piezoelectric Ceramic Resonator (압전 세라믹 진동자를 이용한 초음파 분무기의 분무 특성)

  • Bae, Sang-Tae;Lee, Su-Ho;Sug, Jeong-Young;Kim, Cheol-Hwan;SaGong, Geon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.405-410
    • /
    • 2009
  • The conventional ultrasonic nozzle produces a mist by applying an ultrasonic vibration into a non-flowering liquid. In this paper, we first present a novel designed nozzle type sprayer that is able to apply an ultrasonic vibration directly to the moving liquid and generate a mist instantly. For the novel nozzle, a ring-type actuator of the novel nozzle was designed and built using the PZW-PMN-PZT ceramics. This paper will describe a variety of physical, mechanical, and electrical characteristics of the ultrasonic nozzle. The characteristics of the mist particles was also measured as the amount of the outflow liquid was varied.

3-D Object Recognition and Restoration Independent of the Translation and Rotation Using an Ultrasonic Sensor Array (초음파센서 배열을 이용한 이동과 회전에 무관한 3차원 물체인식과 복원)

  • Cho, Hyun-Chul;Lee, Kee-Seong;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1237-1239
    • /
    • 1996
  • 3-D object recognition and restoration independent of the translation and rotation using an ultrasonic sensor array, neural networks and invariant moment are presented. Using invariant moment vectors on the acquired $16{\times}8$ pixel data, 3-D objects can be classified by SOFM(Self Organizing Feature Map) neural networks. Invariant moment vectors kept constant independent of the translation and rotation. The experiment result shows the suggested method can be applied to the environment recognition.

  • PDF

Efficiency Estimation of Ultrasonic Sensor Fabricated with Porous Piezoelectric Resonator by Experiment of 3-D Underwater Object Recotion (3차원 수중 물체인식 실험에 의한 다공질 압전 초음파 센서의 성능평가)

  • 조현철;이수호;박정학;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.321-324
    • /
    • 1997
  • In this study, Efficiency estimation of ultrasonic sensor fabricated with porous piezoelectric resonator by experiment of 3-D underwater object recognition are presented. The sensor was satisfied with requirement of ultrasonic sensor. The recognition rates for the fixed objects and the translation-rotation objects are 95.3 and 92.7[%], respectively using porous piezoelectric ultrasonic sensor and SOFM neural network. According to the experimental results, It is believed that the self-made ultrasonic sensor can be applied as underwater ultrasonic sensor.

  • PDF

A Study on the Level Limit Switch for Underwater with 1-3 Type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 수중용 레벨 Limit스위치에 관한 연구)

  • Kim, H.G.;Park, K.I.;Shin, K.H;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.292-295
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with 1-3 type composite resonators. Pulse-echo responses of an ultrasonic transducer are investigated in underwater dependent on the variable designated water-level. LED Output signals of a level limit with changing a water level is obtained by the 1-3 type self-made composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level. There was good agreement between the virtual level and output LED signal by using the self-made water-detecting system.

  • PDF

Design and Finite Element Analysis of an Ultrasonic Motor. (초음파 모터의 설계와 유한요소해석)

  • Lee, Seok-Hee;Lee, Chang-Hwan;Jung, Hyun-Kyo;Lee, Jung-Kun;Hong, Kug-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.79-81
    • /
    • 1998
  • This paper presents analytic and numerical analysis of ultrasonic motor, specially linear motion ultrasonic machine. For rough estimation of characteristics of linear ultrasonic motor, the analytic method is used and a three-dimensional numerical analysis with experimental material data using ABAQUS, is performed. The validity of analysis is confirmed by comparing experimental results with numerical ones.

  • PDF

Stabilization of Water Balance of Closed Cooling Water System with Orifice (오리피스를 통한 기기냉각수 계통 Water Balance 정상화)

  • Lee, Sung Gun;Park, Jong Hwan;Lee, Eun Su
    • Plant Journal
    • /
    • v.13 no.4
    • /
    • pp.38-40
    • /
    • 2017
  • This study is for stabilization of the water balance of the closed cooling water system. The pipe network analysis program is used for the water balance review, and the resistance factor correction is performed through the field measurement with the ultrasonic flowmeter to improve the reliability of the pipe network software. Based on this, it is aimed to derive optimal driving method through various case simulations.

  • PDF

Result of a Long-Term Follow-Up of Arthroscopic Partial Repair for Massive Irreparable Rotator Cuff Tears Using a Biceps Long Head Auto Graft (봉합 불가능한 광범위 회전근 개 파열에서 상완 이두근 건 장두를 이용한 관절경하 부분 봉합술의 장기 추적 관찰 결과)

  • Ko, Sang-Hun;Park, Ki-Bong;Park, Gil-Young;Kwon, Sun-Hwan;Kim, Myung-Seo;Park, Sun-Jae
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.135-142
    • /
    • 2020
  • Purpose: This paper presents the long term follow-up results of arthroscopic partial repair for massive irreparable rotator cuff tears using a biceps long head auto graft. Materials and Methods: Forty-one patients with massive irreparable rotator cuff tear, who underwent arthroscopic repair, were reviewed retrospectively. Patients who underwent arthroscopic partial repair using a biceps long head auto graft were assigned to group 1, and patients in group 2 underwent arthroscopic partial repair alone. Patients with a less than 50% partial tear of the long head biceps tendon were included in this study. The clinical scores were measured using a visual analogue pain scale (VAS) for pain, range of motion (ROM), The University of California, Los Angeles shoulder score (UCLA), American Shoulder and Elbow Surgeons Shoulder Score (ASES), and Korean Shoulder Scoring System (KSS) scores preoperatively and at the final follow-up. The acromiohumeral interval (AHI) was measured using plain radiographs taken preoperatively and at the final follow-up, and re-tear was evaluated using postoperative ultrasound or magnetic resonance imaging at the last follow-up. Results: The mean age of the patients was 62.1±12.7 years, and the mean follow-up period was 90.3±16.8 months. No significant differences in the VAS and ROM (forward flexion, external rotation, internal rotation) were found between the two groups (p=0.179, p=0.129, p=0.098, p=0.155, respectively). The UCLA (p=0.041), ASES (p=0.023), and KSS (p=0.019) scores showed functional improvements in group 1 compared to group 2. At the last follow-up, the measured AHI values were 9.46±0.41 mm and 6.86±0.64 mm in group 1 and 2, respectively (p=0.032). Re-tear was observed in six out of 21 cases (28.6%) in group 1 and nine out of 20 cases (45.0%) in group 2; the retear rate was significantly lower in group 1 than in group 2 (p=0.011). Conclusion: Arthroscopic partial repair for a massive irreparable rotator cuff tear using a biceps long head auto graft has significant clinical usefulness in functional recovery and decreases the re-tear rates after surgery than arthroscopic partial repair alone, showing favorable results after a long-term follow-up.

Determination of polycyclic aromatic hydrocarbons in processed foods (가공식품 중 다환방향족탄화수소 분석)

  • Hu, Soo-Jung;Jin, Sun-Hee;Lee, Kwang-Ho;Choi, Dong-Mi
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.196-204
    • /
    • 2010
  • In this study, the following concentrations of some PAHs (Polycyclic Aromatic Hydrocarbons) were investigated; [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in processed foods (n=165) and cooked meats (n=45) and established the analytical method by characteristics of processed foods. The methodology involved extraction (alkali digestion, liquid-liquid extraction, microwave extraction), clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD (High Performance Liquid Chromatography/Fluorescence Detector). The recovery of overall method for 8 PAHs spiked into these products ranged from 92 to 103%. The mean level of detected foods was found to be benzo(b)fluoranthene $0.9\;{\mu}g/kg$ in smoked salmon, benzo(b)fluoranthene $1.0\;{\mu}g/kg$, benzo(k)fluoranthene $0.3\;{\mu}g/kg$, benzo(a)pyrene $0.9\;{\mu}g/kg$ in dried banana, benzo(b)fluoranthene $0.2\;{\mu}g/kg$, benzo(k)fluoranthene $0.1\;{\mu}g/kg$, benzo(a)pyrene $0.2\;{\mu}g/kg$ in smoked chicken, benzo(b)fluoranthene $1.3\;{\mu}g/kg$, benzo(k)fluoranthene $0.3\;{\mu}g/kg$, benzo(a)pyrene $0.9\;{\mu}g/kg$ in charcoal grilled pork, respectively.

Usefulness of $^{18}F$-FDG PET/CT in Locoregional Recurrence of Differentiated Thyroid Cancer: Comparison PET/CT to PET and Neck Ultrasonography for Biopsy-proven Lesions (갑상선유두암 재발 진단에서 $^{18}F$-FDG PET/CT와 경부초음파검사 병용의 유용성: PET, 경부초음파검사 그리고 혈청 티로글로불린 (thyroglobulin)의 비교)

  • Kim, Kun-Ho;Shong, Min-Ho;Seo, Young-Duk;Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.411-420
    • /
    • 2009
  • Purpose: The aim of this study was to investigate the usefulness of $^{18}F$-FDG PET/CT with neck ultrasonography (neck US) in patients with recurrent, papillary thyroid cancer. Material and methods: This retrospective study (December 2006 to April 2008) enrolled sixty-one patients (ninety-one lesions) who underwent high-dose $^{131}I$-ablation therapy after total thyroidectomy, and evaluated recurred papillary thyroid cancer. All lesions were confirmed by histopathology and compared histopathologic findings to PET, PET/CT, and neck US findings. Results: In sixty-one patients (57 women, 4 men; age range, 24-81 years, mean 49 years; 61 papillary carcinomas), the sensitivity, specificity, accuracy of $^{18}F$-FDG PET/CT was 87.2%, 64.0%, 78.1% on a patient basis and 92.3%, 66.7%, 80.9% on a lesion basis, respectively. The sensitivity, specificity, accuracy of $^{18}F$-FDG PET was 71.8% (p=0.03), 59.0% (p=1.00), 67.2% (p=0.03) on a patient basis and 78.8% (p<0.01), 64.1% (p=1.00), 72.5% (p=0.02) on a lesion basis, respectively. The sensitivity, specificity, accuracy of neck US was 71.1% (p=0.07), 52.2% (p=0.75), 63.9% (p=0.05) on a patient basis and 71.2% (p<0.01), 61.5% (p=1.00), 67.0% (p=0.06) on a lesion basis, respectively. Combined $^{18}F$-FDG PET/CT with neck US improved the sensitivity, specificity, accuracy to 94.7% (p=0.50), 82.6% (p=0.13), 90.2% (p=0.03) on a patient basis and 96.2% (p=0.50), 89.7% (p<0.01), 93.4% (p<0.01) on a lesion basis, respectively. Conclusion: $^{18}F$-FDG PET/CT demonstrated significantly higher sensitivity than neck US for the detection of recurred papillary thyroid cancer lesions. Furthermore, combined $^{18}F$-FDG PET/CT with neck US showed more improved sensitivity, specificity, accuracy for diagnosis of recurrent papillary thyroid cancer.