• Title/Summary/Keyword: 초기제외시간

Search Result 217, Processing Time 0.025 seconds

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

Effects of Benzo〔a〕pyrene on Growth and Photosynthesis of Phytoplankton (식물플랑크톤의 성장과 광합성에 대한 benzo〔a〕pyrene의 영향)

  • Kim, Sun-Ju;Shin, Kyung-Soon;Moon, Chang-Ho;Park, Dong-Won;Chang, Man
    • Korean Journal of Environmental Biology
    • /
    • v.22
    • /
    • pp.54-62
    • /
    • 2004
  • We examined the impacts of anthyopogenic pollutant (benzo〔a〕pyrene) on the growth and photosynthesis of five marine phytoplankton species (Skeletonema costatum, Heterosigma akashiwo, Prorocentrum dentatum, P. minimum, Aknshiwo sanguinea), which are dominant in Korean coastal water. After the 72 h exposure to benzo〔a〕pyrene, the dramatic decrease in cell numbers was observed in the range of 1 to 10 $\mu\textrm{g}$ L$^{-1}$ for S. costatum, P. minimum, P. dentatum, whereas for A. sanguinea and H. akashiwo at the low concentrations 0.1 to 1 $\mu\textrm{g}$ L$^{-1}$ . Among the 5 phytoplankton species, the highest growth inhibition concentration ($IC_{50}$/) was 6.20 $\mu\textrm{g}$ L$^{-1}$ for P. minimum, followed by 2.14 $\mu\textrm{g}$ L$^{-1}$ for P. dentatum, 1.68 $\mu\textrm{g}$ L$^{-1}$ for S. costatum, 0.74 $\mu\textrm{g}$ L$^{-1}$ for H. akashiwo, 0.10 $\mu\textrm{g}$ L$^{-1}$ for A. sanguinea. The five species exposed to the low concentration of 1 $\mu\textrm{g}$ L$^{-1}$ were recovered after transferring to new media, but the species exposed to the high concentrations of 10 and 100 $\mu\textrm{g}$ L$^{-1}$ were not recovered, with the exception of P. minimum. Those results indicate that the thecate dinoflagellate P. minimum is most tolerant to the chemical and the athecate dinoflagellate A. sanguinea is not. Geneyally, the cell-specific photosynthetic capacity of H. akashiwo exposed to the low concentrations of 0.1 and 1 $\mu\textrm{g}$ L$^{-1}$ was higher than that of the cells in the control, whereas the cells exposed to the high concentrations of 5 and 10 $\mu\textrm{g}$ L$^{-1}$ showed the negligible photosynthetic level by the first few days of the experiment. In the case of the cells exposed to the concentration of 5 $\mu\textrm{g}$ L$^{-1}$ , after 12 days of the experiment the photosynthetic capacity was increased toward the end of the experiment. This indicates that H. akashiwo may utilize the benzo〔a〕pyrene as a carton source for its growth when exposed to low concentrations. Results suggest that anthropogenic pollutants such as benzo〔a〕pyrene may have significant influence on the succession of phytoplankton species composition and the primary production in coastal marine environments.

Overview of Utilization of Four-wheel Tractor in Korea(I) -Ownership and Annual Use by Different Farm Groups- (농용(農用)트랙터 이용(利用)에 관(關)한 조사연구(調査硏究)(I) -경영형태별(經營形態別) 농작업이용실태분석(農作業利用實態分析)-)

  • Park, Ho Seok;Kim, Kyong Su;Lee, Yong Kook;Han, Sung Kum
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.20-32
    • /
    • 1982
  • This survey was conducted to investigate the present status of farm tractor utilization for obtaining a basic reference to the establishment of the government's agricultural mechanization strategies. Thirty two counties from the eight provinces except Jeju were covered in this study. From these selected areas, 433 sample farms having farm tractor were taken to obtain the general informations by the enquete, and 93 sample farms among them to investigate the status of daily tractor use in the year of 1980. The analyzed results are summarized as follows: 1. Farm tractors owned by the rice-oriented farms holds 71.5 percent of the total number of tractors the livestock-oriented farms 17.0 percent, and the orchard-oriented farms 7.0 percent. Among the farm tractors 64.3 percent was a large size (46ps) and 35.7 percent a small size(19~23ps). 2. Most of the tractors surveyed were equipped with the essential attachments such as plow and rotavator. About 18 percent of the tractor owners had no trailer, which seemed too high considering the large percentage of tractor use for transportation. The availability of other attachments was very low except a grader on the rice-oriented farms and a hay harvester and a front loader on the livestock-oriented farms. 3. The average size of farm was 3.9 hectare for the rice-oriented farms, 13.9 hectare for the livestock-oriented farms and 7.4 hectare for the orchard-oriented farms. It was obious that the average farm size of was too small compared to the theoretical machine capacity of the tractors. 4. About 70 percent of the tractor operators were in the age of twenties and thirties. About 90 percent of them had an educational level of middle school graduate or above even though their technical level was very low. 5. Any particular problem in tractor use was not found in this survey. From the farmer's preference for purchasing a new tractor, however, it is estimated the demand on a 20-30ps tractor will be more increased. 6. The average annual use of tractor was of about 100 days or 400 hours. It appeared that the rice-oriented farms used most with 412.4 hours per year, and followed by the livestock-oriented farms with 403.6 hours, the orchard oriented farms with 377.7 hours. 7. Among the total hours of tractor use, 47.3 percent was for transportation, and 41.6 percent was for plowing and rotary tillage. The largest portion of the annual tractor use was taken by transportation on the livestock-oriented farms, by land preperation on the rice-oriented farms, and by loading and chemical spraying on the orchard-oriented farms. 8. The hours of tractor use had a peak in May. The hours of use for own farm was remarkably different among the different farm oriented, but there was no considerable difference between the too different sizes of tractor. 9. The hours of tractor use decreased as the age of the operator or the educational level increased. The reason might be that the operators who had a high educational level or were older had a tendency of disliking custom works. 10. The average custom use of tractor was 171.3 hours per year, and the ratio of custom work was 63.7 percent on the rice-oriented farms, 31.7 percent on the livestock-oriented farms and 22.4 percent on the orchard-oriented farms. Among the custom works, the most popular one was the grader leveling. 11. The charge on custom work was about 40,000 Won per hectare for plowing and rotary tillage, and it was the most expensive in the southeastern region, and next followed by the southwestern region. 12. The average plowing capacity of the small tractor was 7.8 hours per hectare in the paddy field, and that of the large tractors was 4.3 hours per hectare. The average rotary-tilling capacities of the small and the large tractors were 6.5 and 4.3 hours per hectare, in the paddy field respectively.

  • PDF

Decentralized Composting of Garbage in a Small Composter for Dwelling House I. Laboratory Composting of the Household Garbage in a Small Bin (가정용 소형 퇴비화용기에 의한 부엌쓰레기의 분산식 퇴비화 I. 실험실 조건에서 퇴비화 연구)

  • Seo, Jeoung-Yoon;Joo, Woo-Hong
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.3
    • /
    • pp.321-337
    • /
    • 1994
  • The garbage from the dwelling houses was composted in two kinds of small composter in laboratory to investigate the possibility of garbage composting. They were general small composters. One (type 1) was insullated but the other (type 2) was not. Because it was found that type 2 was not available for composting under our meteorological conditions through winter experiment, only type 1 was tested in spring and summer. The experiment was performed for 8 weeks in each season. The seasonal variation of several compounds in compost was evaluated and discussed. The result summarized belows are those taken at the end of the experiment, if the time was not specified. 1) The maximum temperature was $58^{\circ}C$ in spring, $57^{\circ}C$ in summer and $41^{\circ}C$ in winter. This temperature was enough to destroy the pathogen except for winter. 2) The mass was reduced to average 62.5% and the volume reduction was avergae 74%. 3) The density was estimated as 0.7kg/l in spring, 0.8kg/l in summer and 1.1kg/l in winter. 4) The water content was not much changed for composting periods. It had 75.6% in spring and 76.6% in summer and winter. 5) There was a great seasonal difference in pH value. It was reached to pH 6.13 in spring, pH 8.62 in summer and pH 4.75 in winter. 6) The faster organic matter was decomposed, the greater ash content was increased. Cellulose and lignin content were increased, but hemicellulose content was reduced during composting period. 7) Nitrogen contents were in the range of 3.1-5.6% and especially high in summer. After ammonium nitrogen contents were increased at the early stage of composting period, they were decreased. The maximum ammonium nitrogen content was 3,243mg/kg after 2 weeks in winter, 6,053mg/kg after 3 weeks in spring and 30,828mg/kg after 6 weeks in summer. C/N-ratios were not much changed. Nitrification occurred actively in spring and summer. 8) The contents of volatile and higher fatty acids were increased in early stage of composting and reduced after that. The maximum content of total fatty acid was 10.1% after 2 weeks in winter, 5.8% after 2 weeks in spring and 15.7% after 4 weeks in summer. 9) The contents of inorganic compounds were not accumulated as composting was proceeded. They were in the range of 0.9-4.4% $P_2O_5$, 1.6-2.9% $K_2O$, 2.4-4.6% CaO and 0.30-0.80% MgO. 10) CN and heavy metal contents did not show any tendency. They were in the range of 0.11-28.99mg/kg CN, 24-166mg/kg Zn, 5-129mg/kg Cu, 0.8-14.3mg/kg Cd, 7-42mg/kg Pb, ND-30mg/kg Cr and $ND-132.16\;{\mu}g/kg$ Hg.

  • PDF

The Early Experience with a Laparoscopy-assisted Pylorus-preserving Gastrectomy: A Comparison with a Laparoscopy-assisted Distal Gastrectomy with Billroth-I Reconstruction (복강경 보조 유문부보존 위절제술의 초기 경험: 복강경 보조 원위부 위절제술 후 Billroth-I 재건술과의 비교)

  • Park, Jong-Ik;Jin, Sung-Ho;Bang, Ho-Yoon;Chae, Gi-Bong;Paik, Nam-Sun;Moon, Nan-Mo;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose: Pylorus-preserving gastrectomy (PPG), which retains pyloric ring and gastric function, has been accepted as a function-preserving procedure for early gastric cancer for the prevention of postgastrectomy syndrome. This study was compared laparoscopy-assisted pylorus-preerving gastrectomy (LAPPG) with laparoscopy-assisted distal gastrectomy with Billroth-I reconstruction (LADGB I). Materials and Methods: Between November 2006 and September 2007, 39 patients with early gastric cancer underwent laparoscopy-assisted gastrectomy in the Department of Surgery at Korea Cancer Center Hospital. 9 of these patients underwent LAPPG and 18 underwent LADGBI. When LAPPG was underwent, we preserved the pyloric branch, hepatic branch, and celiac branch of the vagus nerve, the infrapyloric artery, and the right gastric artery and performed D1+$\beta$ lymphadenectomy to the exclusion of suprapyloric lymph node dissection. The distal stomach was resected while retaining a $2.5{\sim}3.0\;cm$ pyloric cuff and maintaining a $3.0{\sim}4.0\;cm$ distal margin for the resection. Results: The mean age for patients who underwent LAPPG and LADGBI were $59.9{\pm}9.4$ year-old and $64.1{\pm}10.0$ year-old, respectively. The sex ratio was 1.3 : 1.0 (male 5, female 4) in the LAPPG group and 2.6 : 1.0 (male 13, female 5) in the LADGBI group. Mean total number of dissected lymph nodes ($28.3{\pm}11.9$ versus $28.1{\pm}8.9$), operation time ($269.0{\pm}34.4$ versus $236.3{\pm}39.6$ minutes), estimated blood loss ($191.1{\pm}85.7$ versus $218.3{\pm}150.6\;ml$), time to first flatus ($3.6{\pm}0.9$ versus $3.5{\pm}0.8$ days), time to start of diet ($5.1{\pm}0.9$ versus $5.1{\pm}1.7$ days), and postoperative hospital stay ($10.1{\pm}4.0$ versus $9.2{\pm}3.0$ days) were not found significant differences (P>0.05). The postoperative complications were 1 patient with gastric stasis and 1 patient with wound seroma in LAPPG group and 1 patient with left lateral segment infarct of liver in the LADGB I group. Conclusion: Patients treated by LAPPG showed a comparable quality of surgical operation compared with those treated by LADGBI. LAPPG has an important role in the surgical management of early gastric cancer in terms of quality of postoperative life. Randomized controlled studies should be undertaken to analyze the optimal survival and long-term outcomes of this operative procedure.

  • PDF

Design of the Condenser and Automation of a Solar Powered Water Pump (태양열 물펌프의 운전 자동화 설계)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;Lee Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.141-154
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which the electrical power is not available. The average so]ar radiation energy is 3.488 kWh/($m^2{\cdot}day$) in Korea. In this study, the automatic control logic and system of the water pump driven by the radiation energy were studied, designed, assembled, tested and analyzed for realizing the solar powered water pump. The experimental system was operated automatically and the cycle was continued. The average quantity of the water pumped per cycle was about 5,320 cc. The cycle time was about 4.9 minutes. The thermal efficiency of the system was about $0.030\%$. The pressure level of the n-pentane vapour in flash tank was 150$\%$450 hPa(gauge) which was set by the computer program for the control of the vapour supply. The pressure in the condenser and air tank during cycles was maintained as about 600 hPa and 1,200 hPa respectively. The water could be pumped by the amount of 128kg/($m^2{\cdot}day$) with the efficiency of $0.1\%$ and the pumping head of 10 m for the average solar energy in Korea.

  • PDF

Fate and Transport of Cr(VI) Contaminated Groundwater from the Industrial Area in Daejeon (대전 산업단지 지하수의 6가 크롬 오염 및 확산 평가)

  • Chon, Chul-Min;Moon, Sang-Ho;Ahn, Joo-Sung;Kim, Yung-Sik;Won, Jong-Ho;Ahn, Kyoung-Hwan
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.403-418
    • /
    • 2007
  • The objective of this research was to characterize the fate and transport of Cr(VI) contaminated groundwater in the Daejeon industrial area. Five subsidiary monitoring wells were newly installed and two existing wells were utilized for the investigation and the reduction process of Cr(VI) contaminated groundwater of the Daejeon(Mun-pyeong) national groundwater monitoring station. The Cr(VI) concentrations at the shallow aquifer well of the station were in the range of 3.2-4.5 mg/L indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other monitoring wells except MPH-1 and 3. The Cr(VI) concentrations of MPH-1 and MPH-3 were below the drinking water guideline value (0.05 mg/L). Therefore, the plume of the Cr(VI) contaminated groundwater was predicted to be confined within the narrow boundary around the station. The soluble/exchangeable Cr(VI) concentrations were below the detection limit in all core and slime samples taken from the five newly installed wells. Although the exact source of contamination was not directly detected in the study area, the spatial Cr(VI) distribution in groundwater and characteristics of the core samples indicated that the source and the dispersion range were confined within the 100 m area from the monitoring station. The contamination might be induced from the unlined landfill of industrial wastes which was observed during the installation of an subsidiary monitoring well. For the evaluation of the natural attenuation of Cr(VI), available reduction capacities of Cr(VI) with an initial concentration of 5 mg/L were measured in soil and aquifer materials. Dark-gray clay layer samples have high capacities of Cr(VI) reduction ranging from 58 to 64%, which is obviously related to organic carbon contents of the samples. The analysis of reduction capacities implied that the soil and aquifer materials controlled the dispersion of Cr(VI) contamination in this area. However, some possibilities of dispersion by the preferential flow cannot be excluded due to the limited numbers of monitoring wells. We suggest the removal of Cr(VI) contaminated groundwater by periodical pumping, and the continuous groundwater quality monitoring for evaluation of the Cr(VI) dispersion should be followed in the study area.

A Neurobehavioral Performance Assessment in Lacunar Infarction Case-control Study (열공성 뇌경색 환자-대조군에서 신경행동검사의 수행 평가)

  • Kim, Ham-Gyum;Park, Sue-Kyung;Lee, Kun-Sei;Kim, Hyeoug-Su;Kim, Wha-Sun;Chang, Soung-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.3
    • /
    • pp.255-262
    • /
    • 2003
  • Objectives : We carried out tests for neurobehavior by using WHO-NCTB (neurobehavioral core test battery) and Perdue pegboard score test to identify differences between lacunar infarction cases and controls. Methods : Among the subjects who underwent MRI between February 2001 and March 2002 in a university hospital located in Seoul and who were diagnosed only as lacunar infarction without any intracranial disease, 46 patients were selected as cases (male: 21, female: 25). Controls were selected who had no cerebrovascular disease on MRI by matching age (5 years), gender, and education (2 years) in a ratio of 1:1 , Among WHO-NCTB, the following 5 tests and Perdue pegboard score test were used to categorize the study subjects: digit and symbol matching, simple reaction time, Benton visual retention, digit span, and Pursuit aiming test, Results : Among the above 6 tests of neurobehavior, lacunar infarction cases showed lower score than controls except for the simple reaction time test. As the controlling variables of multivariate analysis in the stepwise regression analysis, the followings were selected due to their significant association: age, education, BMI, gender, drinking, exercise, add systolic blood pressure. From multivariate regression analysis, there was significant difference (p<0.05) between lacunar infarction cases and controls in digit and symbol matching, Benton visual retention, digit span, pursuit aiming, and Perdue pegboard score test, but not in the score of simple reaction time test. Conclusions : We suggest that the above 5 tests for neurobehavior, with the exception of the simple reaction time test, might be used as the basis for recommendation of further treatment and other neurological tests by the earlier defection for neurological abnormality in lacunar infarction.

Comparison of Characteristics on Electrolyzed Water Manufactured by Various Electrolytic Factors (전해인자에 따른 전기분해수의 특성 비교)

  • Kim, Myung-Ho;Jeong, Jin-Woong;Cho, Young-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.416-422
    • /
    • 2004
  • Efficacy of surface sterilization and physicochemical properties of electrolyzed water manufactured depending on electrolyte, materials, and type of electrolytic diaphragm used were investigated. Physical properties of electrolyzed water manufactured from diaphragm system showed the highest effectiveness under at distance between diaphragms of 1.0 mm and 20% NaCl supplying rate of 6 mL/min. ORP, HClO (should defined) content, and pH at above conditions were 1,170 mV, 100 ppm, and 2.5, respectively. Two-stage electrolyzed system was more effective than one-stage one. Electrolyzed water manufactured from non-diaphragm system at 4 mL/min supplying rate of 20% NaCl was similar to the most effective diaphragm system, whereas ORP, HClO content, and pH were 800 mV, 200 ppm, and 9, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORPs of 750 and 1,150 mV in non-diaphragm and diaphragm systems, respectively, and at HClO content of 100 ppm. Physicochemical properties of electrolyzed water manufactured from electrolytic diaphragm of $IrO_{2}$ and Pt+Ir were more effective than that of Pt. ORP and HClO contents of electrolyzed water manufactured from various electrolytes were high in order of NaCl>KCl>$CaCl_{2}$, whereas no differences were observed among electrolytes in sterilization efficacy. Twelve kinds of microorganisms tested (initial total count, $10^{5}-10^{6}CFU/mL$) were sterilized within 1-2 min by electrolyzed water.

Study on the Soil Improvement in the Grassland I. Effects of the dolomite particle and the shell powder application on soil characteristics, dry matter yield and nutritive value of forages in loam soil (초지에서 토양 개량에 관한 연구 I. 양토에서 도로마이트 입자도와 패각분 시용이 토양특성과 목초의 수량 및 사료가치에 미치는 영향)

  • Lee, J.K.;Choi, S.S.;Kim, M.J.;Park, G.J.;Yoon, S.H.;Shin, J.S.;Shin, D.E.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.19 no.2
    • /
    • pp.159-166
    • /
    • 1999
  • This study was conducted to investigate the effects of application of the dolomite particle and the shell powder on soil characteristics, dry matter yield and nutritive value of forages in loam soil at the experimental field of National Livestock Research Institute, Suwon, from 1994 to 1996. Application treatments were control, lime, dolomite 0.5, 2.0, 4.0mm, and shell powder in mixed pasture. Rate of dust occurrence was greatly decreased according to dolomite application and the dissolving rate in soil was highest in shell powder application among treatments. Although there was no significant difference, average dry matter yield of forages for 3 years was slightly increased with the application of lime, shell powder, dolomite 0.5mm, 4.0mm, 2.0mm and control in order. Both Ca and Mg contents of forages were no differences among treatments in 1994. However, all treatments were higher than those of control in 1995. And K and Na contents of forages were no differences among treatments. Lime requirement was greatly increased from 2,630 to 6,150kg per ha with the lapse of time. Although soil hardness was optimum level at first, it was likely to become hard little by little after treatments. Solid phase of soil was lowered a little except for control. Organic matter and available $P_2O_5$ contents of soil were highest in shell powder application among treatments, and K, Ca and Mg contents of soil were no differences among treatments. Ca content was increased a little in 1995, but decreased a little in 1996 compared to that of soil before treatments in 1994. AIso, Mg content was lowered than that of soil before experiment in 1995 and 1996. The results demonstrated that use of dolomite and shell powder as lime substitutes could be reduced dust problem and coast pollution as well as soil improvement. Therefore, it is desirable to apply the dolomite and the shell powder every 3 years in loam soil.

  • PDF