• Title/Summary/Keyword: 초고압 송전선로 설계

Search Result 18, Processing Time 0.029 seconds

Development of Formulas for Predicting Radio Noise from Overhead HVAC Transmission Lines using Least Squares Optimization Method (최소자승법에 의한 초고압 가공 송전선로의 라디오 잡음장해 예측계산식 개발)

  • Yang, Gwang-Ho;Ju, Mun-No;Myeong, Seong-Ho;Sin, Gu-Yong;Lee, Dong-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • The radio noise produced by corona discharge in high voltage transmission lines is one of the most important line design considerations. Therefore it is necessary for transmission line designers to pre-evaluate radio noise using prediction formulas or field test results. In this paper, more accurate and useful formulas for predicting radio noise during fair and foul weathers in high voltage AC transmission lines were proposed through comparison with the existing formulas. Also it was verified by comparing with the long-term measured data from operating lines that the proposed formulas are more accurate. The proposed prediction formulas are developed by the applications of nonlinear least squares optimization method to radio noise database collected from lines throughout the world.

  • PDF

Electric Environmental test for Low Wind Noise Conductor Development in UHV T/L (초고압 송전선로용 저풍소음 전선 개발을 위한 전기환경 시험)

  • Lee, Dong-I.;Shin, Koo-Y.;Lee, Seong-D.;Yang, Kwang-H.;Ju, Mun-N.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.475-477
    • /
    • 2002
  • 본 논문에서는 765kV 송전선로의 일부구간에서 발생되고 있는 풍소음의 대책으로 개발된 저풍소음 도체를 소개하고 이 도체방식을 개발하기 위해 수행된 전기환경장해 및 풍소음 저감 영향에 대한 시험결과를 제시하고 있다. 저풍소음 도체는 우수한 풍소음 저감기능을 가지면서도 기존 전선에 비해 추가적인 전기환경 문제가 발생되지 않아야 하는데, 기존 전선과 달리 전선 주위에 돌기부가 있어서 전계 집중에 따른 환경장해 발생의 우려가 있다. 이러한 이유 때문에 전기환경 모의시험설비인 코로나 케이지를 이용한 코로나 발생 특성 시험을 수행하여 환경설계기준 만족 여부를 확인하였으며, 실규모 시험선로를 이용한 장기 실증시험을 실시하여 송전선로 주변에서 실제 발생 가능한 라디오 장해와 같은 전기환경 장해량에 대한 평가를 실시하여 풍소음 저감효과와 환경설계기준에 만족하는 결과를 얻을 수 있었다.

  • PDF

A Study of Loop Design for Magnetic Fields Mitigation or Transmission Line using a Genetic Algorithms (유전알고리듬을 이용한 송전선로의 자계 저감 루프설계에 관한 연구)

  • Lee, K.H.;Kim, D.H.;Kim, J.H.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.99-101
    • /
    • 2005
  • 전력수요의 지속저인 증가로 인해 초고압(EHV) 송전선로를 포함한 전력선비가 계속 건설됨에 따라 송전선로에서 발생하는 전자계에 관한 논란이 심화될것으로 예상된다. 본 논문에서는 이러한 문제를 해소하기 위해 효과적으로 전자계를 저감시킬 수 있는 저감 기법중 송전선로 주변에 수동 도체루프를 사용하여 자계를 저감시키는 방법을 검토하고 유전 알고리듬을 이용해 가공송전선로에서 발생하는 자계를 효과적으로 저감시키기 위한 최적의 도체루프 모델을 찾고자 하였다.

  • PDF

Electrical Environmental Effects of Power System (전력설비의 전기환경장해)

  • 신구용;이동일;윤진열;김상범;김정부
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.24-31
    • /
    • 1999
  • This paper describes the characteristics and the criteria of electrical envirionmental effects produced from power systam, especially transmission line. Audible noise, radio and TV interlerence, electric and magnetic inductions which are main items for optimal conductor selection as well as major contributors to the community complaint of electrical envirorurental problem, are surveyed and studied comparing with the criteria or the envirorurental protection regulation of domestic and foreign countries. As a result, a domestic criteria of electrical envirorurental on power system was suggested.gested.

  • PDF

Development of Audible Noise Prediction Formulas Applied to HVAC Transmission Lines Design by Using Genetic Programming (유전프로그래밍에 의한 초고압 송전선로 환경설계용 코로나 소음 예측계산식 개발)

  • Yang, Kwang-Ho;Hwang, Gi-Hyun;Park, June-Ho;Park, Jong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.5
    • /
    • pp.234-240
    • /
    • 2001
  • Audible noise (AN) produced by corona discharges from high voltage transmission lines is one of the more important considerations in line design. Therefore, line designers must pre-determine the AN using prediction formulas. This paper presents the results of applying evolutionary computation techniques using AN data from lines throughout the world to develop new, highly accurate formulas for predicting a A-weighted AN during heavy rain and stable rain from overhead ac lines. Calculated ANs using these new formulas and existing formulas are compared with measured data.

  • PDF

A New Environmentally Friendly Design Program TLCALC for High Voltage AC Transmission Lines (새로운 초고압 송전선로 친환경설계프로그램 TLCALC)

  • Yang, Kwang-Ho;Myung, Sung-Ho;Kil, Gyung-Suk;Hwang, Gi-Hyun;Lee, Dong-Il;Ju, Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.4
    • /
    • pp.151-155
    • /
    • 2006
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environmental design software, TLCALC(Transmission Line CALCulation) for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient. TLCALC solved a few problems in use of the existing foreign tools and took several advantages as follows; (1) It is a common tool that solves calculating limitations of foreign formulas, (2) It has wide application ranges and enhances accuracy of prediction. (3) It can be applied to almost transmission line configurations in Korea. (4) Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC is easy and practical, this program will be usefully applied to the environmental friendly design and construction of transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC.

Study on the Air Insulation Design Guideline for ±500 kV Double Bipole Transmission Line with Metallic Return Conductor (도체귀로형 ±500 kV Double Bipole 송전선로 공기절연에 관한 연구)

  • Shin, Kooyong;Kwon, Gumin;Song, Seongwhan;Woo, Jungwook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.141-147
    • /
    • 2019
  • Recently, the biggest issue in the electricity industry is the increase in renewable energy, and various technologies are being developed to ensure the capacity of the power system. In addition, super-grids linking power systems are being pushed to utilize eco-friendly energy between countries and regions worldwide. The HVDC transmission technology is required to link the power network between regions with different characteristics of the power system such as frequency and voltage. Until now, Korea has applied HVDC transmission technology that connects mainland and Jeju Island with submarine cables. But, the HVDC transmission technology is still developing for long-distance high-capacity power transmission from power parks on the east coast to load-tight areas near the metropolitan area. Considering the high population density and mountainous domestic environment, it is pushing for commercialization of the design technology of the ${\pm}500kV$ Double Bipole with metallic return wire transmission line to transmit large-scale power of 8 GW using minimal right of ways. In this paper, the insulation characteristics were studied for the design of double-bipole transmission tower with metallic return wire, which is the first time in the world. And the air insulation characteristics resistant to the various overvoltage phenomena occurring on transmission lines were verified through a full-scale impulse voltage test.

Development & Practical Installation of 400kV XLPE 1C${\times}$2500SQ Enamel coating Power Cable Accessories (400kV Enameled Cu 1C${\times}$2500SQ 케이블 접속재 개발 및 실선로 적용)

  • Kim, Young-Tek;Kim, Hyun-Ju;Kim, Han-Hwa;Park, Jeong-Ki;Han, Du-Hyun;Choi, Man-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1614-1616
    • /
    • 2011
  • 지중송전라인에서 전압등급의 상승은 선로손실을 줄이면서 밀집된 전력수요에 대응하거나 특별히 고전압 수요를 맞추기 위한 것으로 이것은 XLPE Cable의 제조기술이 향상되면서 지속적으로 진행되어온 초고압송전계통의 일반적 추세이다. 이러한 경향으로 해외에서는 케이블 도체의 송전용량을 증대시킬 수 있는 방법으로 케이블 도체에 에나멜 코팅을 하여 집합을 한다. 그러므로써 기존 케이블에서 발생되는 표피현상 및 근접효과에 의한 AC 저항 요소를 줄여 요구하는 전류용량을 기존 비소선절연 케이블에 비해 더 많이 송전할 수 있다. 하지만, 소선절연 케이블이 전류 용량을 증대 시킬 수 있는 장점은 있으나 접속재의 경우 도체의 에나멜 코팅을 제거해야 하는 문제점이 있다. 당사는 에나멜 코팅을 제거하는 방법을 개발 완료함으로써 본 접속재의 개발을 앞당길 수 있었다. 당사는 쿠웨이트 400kV MEW/C/3931 Project에 400kV XLPE 1C${\times}$2500SQ 소선절연 초고압송전라인을 적용하였는데 본고에서는 여기에 적용된 400kV XLPE 1C${\times}$25000SQ 소전절연 케이블 부속재의 신뢰성을 높이기 위한 설계방법, 시험 및 시공에 대하여 요약하였다.

  • PDF