• Title/Summary/Keyword: 체표변화율

Search Result 14, Processing Time 0.02 seconds

Analysis of Changes in Hand Length Dimensions by Hand Motion for Glove Design (장갑 설계 적용을 위한 손동작에 따른 손체표의 길이변화 분석)

  • Kwon, O-Chae;Sun, Mee-Sun;Jung, Ki-Hyo;Lee, Min-Jeong;Yeon, Soo-Min;You, Hee-Cheon;Kim, Hee-Eun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.1-5
    • /
    • 2005
  • A glove design which reflects the changes in hand surface by hand motion can reduce the undesirable effects of use of gloves on hand performance. The present study examined changes in hand length dimensions due to hand motion and identified significant factors affecting the length changes. Recruiting 120 males and females in their 20s and 30s having various hand lengths, this study measured 10 hand length dimensions, defined at 2 hand areas(phalangeal and metacarpal areas) for 5 digits, when the hand is stretched and in fist, and then calculated the percentage of length increase for each dimension. ANOVA and simple-effect analyses showed the length change percentages were mainly different depending on digit and hand area: 111-127% at the phalangeal area and 112-116% at the metacarpal area. The length change percentages of the index, middle, ring, and little fingers in the phalangeal area ascended in order and showed a high correlation(r = 0.94)with the ranges of motion of the fingers.

A Study of Electrode Locations for Design of ECG Monitoring Smart Clothing based on Body Mapping (심전도 모니터링 스마트 의류 디자인을 위한 바디매핑 기반 전극 위치 연구)

  • Cho, Hakyung;Cho, Sang woo
    • Fashion & Textile Research Journal
    • /
    • v.17 no.6
    • /
    • pp.1039-1049
    • /
    • 2015
  • The increase in the need for a 24 hour monitoring of biological signals has been accompanied by an increasing interest in wearable systems that can register ECG at any time and place. ECG-monitoring clothing is a wearable system that records heart function continuously, but there have been difficulties in making accurate measurements due to motion artifacts. Although various factors may cause noise in measurements due to motion, the variations in the body surface and clothing during movements that cause eventual the shifting and displacement of the electrodes is particularly noteworthy. Therefore, this study used biomedical body mapping and a motion-capture system to measure and analyze the changes in the body surface and garment during movements. It was deduced that the area where the friction and separation between the garment and skin is the lowest would be the appropriate location to place the ECG electrodes. For this study, 5 male and 5 female in their 20s were selected as subjects, and through their selected body movements, the changes in the garment and skin were analyzed using the motion-capture system. As a result, the area below the chest circumference and the area below the shoulder blades were proposed as the optimal location of electrode for ECG monitoring.

소재의 신장율에 따른 슬렉스 원형 연구

  • 정희순;이순원
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.7-12
    • /
    • 1998
  • 쾌적한 의생활을 영위하기 위해, 인간의 제반 특성에 적합한 의복 설계에 관한 연구가 활발히 전개되고 있다. 기존 연구에서는 주로 인체 인자에 근거하여 의복 원형 연구가 이루어졌으나 인간 특성에 적합한 의복의 설계를 위해 인체 인자와 함께 의복 인자를 병행한 연구의 필요성이 대두되고 있다. 특히 의복 소재의 경우, 성유과학의 발달로 다양한 의복 소재가 개발되고 있음에도 불구하고 대부분의 의복 원형 연구에서는 광목으로 제한되어 연구가 행해지고 있는데, 광목이 원형 연구시 동작에 따른 체표 변화에 대응하기 위한 여유분으로 정확히 산출할 수 있다는 특징이 있기는 하지만 이로 인하여 의복 원형의 여유 분 설정에 소재의 특성에 따른 차이에 관해서는 아직 까지 많은 연구가 진행되지 못하였다. 이에 본 연구 에서는 최근 마른 체형의 선호와 함께 유행하고 있는 신축성 소재를 이용한 슬랙스 원형에 대하여 연구 하였다. 본 연구는 소재의 신장특성과 의복 설계와의 관계에 대한 기초 자료로써 활용될 수 있을 것이며, 또한 슬랙스 원형에 대한 연구를 보다 다양한 소재로 넓힘으로써 원형의 활용도를 높힐 수 있을 것으로 기대한다.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

A Study of the Basic Design for Smart Clothing based on Measurement of the Respiration (호흡 측정 기능의 스마트 의류를 위한 기초 디자인 연구)

  • Cho, Ha Kyung;Min, Se Dong
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.415-424
    • /
    • 2012
  • According to introduction of Well-Being lifestyle and ageing society, vital sign monitoring system which can be continued measurement of vital sign has been increased their important in field of the healthcare. Under this trend, Respiration monitoring system has been studied and developed in a various way to apply continued monitoring and non-conscious monitoring system. But, Study of the respiration monitoring system based on consumer needs and usability test is insufficient. In this study, Textile capacitive pressure sensor(TCPS) of belt type was developed and tested it's utility and subjective sensibility. TCPS measures respiration signals and can be derived in real time monitoring. As a result, monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rate (correlation (r=0.9553, p<0.0001). In the result of usability and wearability test, all of categorizes(perceived change, wearability, movement, facility of management, usefulness) were received favorable evaluation on usability test( mean value : 3.8), and suitable location of TCPS in the clothing is deriven on the abdomen part. According to synthetical results, Basic smart clothing design based on respiration monitoring system is proposed.

  • PDF

Effects of Regular Exercise and Diet on RMR and Hormonal Changes in Obese Women. (규칙적 운동 및 식이요법이 비만여성의 안정시대사량과 호르몬 변화에 미치는 영향)

  • Park, Hyong-Ran;Paik, Il-Young;Jin, Hwa-Eun;Kim, Young-Il;Kwak, Yi-Sub;Woo, Jin-Hee
    • Journal of Life Science
    • /
    • v.18 no.6
    • /
    • pp.865-870
    • /
    • 2008
  • The purpose of this study was to examine resting metabolic rate (RMR) and thyroid hormonal (TSH, $T_3$, and $T_4$) changes following weight loss by diet with regular exercise in obese women. The subjects of the present study were 7 women who were above 30% body fat. The subjects arrived into the laboratory in the morning after 12 hour overnight fasting. All subjects measured RMR, % body fat, and fat free mass at weight loss program start time, after 4 weeks and after 8 weeks. All the RMR values were expressed as absolute value (kcal/day), absolute value/FFM (kcal/day/FFM), and absolute value/BSA (kcal/$m^2$/hr), and were calculated predicted RMR value minus actual RMR value. Also, correlation of blood thyroid hormonal (TSH, $T_3$, and $T_4$) secretion and RMR were analyzed. There were significant differences in weight, % body fat, and BSA following diet with exercise (p<0.05). Also, there was a difference between predicted RMR and actual RMR value following weight loss (p<0.05). We also examined the hormonal changes according to weight loss. After weight loss, the level of TSH and $T_4$ were higher than before. But there were no significant differences. Also, the level of $T_3$ was lower than rather before but there was no significant difference. Among the anthropometric factors, FFM was highly correlated (r=0.761) with actual RMR value before weight loss. Also, there was a correlation (r=0.771) with actual RMR value after weight loss. Therefore, actual RMR expressed as FFM increased in weight loss program by diet with exercise. There were no changes in the level of thyroid hormonal TSH and $T_4$.

Effects of garlic Allium sativum extract immersion on the immune responses of olive flounder Paralichthys olivaceus prechallenged with pathogenic bacteria (어류 병원성 세균 공격 후 마늘, Allium sativum 착즙액의 침지가 넙치, Paralichthys olivaceus 의 면역반응에 미치는 영향)

  • Woo, Sung-Ho;Lee, Jun-Hee;Kim, Yi-Kyung;Cho, Mi-Young;Jung, Sung-Hee;Kim, Jin-Woo;Park, Soo-Il
    • Journal of fish pathology
    • /
    • v.23 no.2
    • /
    • pp.199-209
    • /
    • 2010
  • This study was aimed to investigate the effects in different immersion doses of garlic, Allium sativum, juice to modulate on the nonspecific immune responses of the olive flounder, Paralichthys olivaceus, artificially prechallenged with Streptococcus iniae BS10 and Edwardsiella tarda KE-1, respectively. The nonspecific immune responses of the tested fish were assessed in term of skin mucus lysozyme activity, the change of bacterial cell counts in organs, the number of lymphocytes and neutrophils in blood, and SOD activity. Almost groups of the prechallenged with either S. iniae BS10 or E. tarda KE-1 fish which had been immersed in garlic juice showed the enhanced skin mucus lysozyme activity, the number of lymphocytes and neutrophils in blood, and SOD activity in the kidney but the decreased the number of bacterial cell in surveyed organs. RPS in the group immersed in 0.25 g/L of garlic juice was much higher than in other immersed test groups. These results suggested that the garlic juice immersion can be effective on enhancement of the nonspecific immune responses and the protective ability of olive flounder to the artificial challenge with S. iniae BS10 and E. tarda KE-1.

Development of the Whole Body 3-Dimensional Topographic Radiotherapy System (3차원 전신 정위 방사선 치료 장치의 개발)

  • Jung, Won-Kyun;Lee, Byung-Yong;Choi, Eun-Kyung;Kim, Jong-Hoon;An, Seung-Do;Lee, Seok;Min, Chul-Ki;Park, Cham-Bok;Jang, Hye-Sook
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1999
  • For the purpose of utilization in 3-D conformal radiotherapy and whole body radiosurgery, the Whole Body 3-Dimensional Topographic Radiation Therapy System has been developed. Whole body frame was constructed in order to be installed on the couch. Radiopaque catheters were engraved on it for the dedicated coordinate system and a MeV-Green immobilizer was used for the patient setup by the help of side panels and plastic rods. By designing and constructing the whole body frame in this way, geometrical limitation to the gantry rotation in 3-D conformal radiotherapy could be minimized and problem which radiation transmission may be altered in particular incident angles was solved. By analyzing CT images containing information of patient setup with respect to the whole body frame, localization and coordination of the target is performed so that patient setup error may be eliminated between simulation and treatment. For the verification of setup, the change of patient positioning is detected and adjusted in order to minimize the setup error by means of comparison of the body outlines using 3 CCTV cameras. To enhance efficiency of treatment procedure, this work can be done in real time by watching the change of patient setup through the monitor. The method of image subtraction in IDL (Interactive Data Language) was used to visualize the change of patient setup. Rotating X-ray system was constructed for detecting target movement due to internal organ motion. Landmark screws were implanted either on the bones around target or inside target, and variation of target location with respect to markers may be visualized in order to minimize internal setup error through the anterior and the lateral image information taken from rotating X-ray system. For CT simulation, simulation software was developed using IDL on GUI(Graphic User Interface) basis for PC and includes functions of graphic handling, editing and data acquisition of images of internal organs as well as target for the preparation of treatment planning.

  • PDF

A study on Palpation of the back-shu points (배유혈(背兪穴) 안진(按診)에 관(關)한 고찰(考察))

  • Hong, Mun-Yeup;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.155-173
    • /
    • 2000
  • The diagnosis in Oriental medicine is done by inspection, auscultation and olfaction, interrogation, four diagnostics of pulse feeling and palpation, and various system of identification like identification according to Qi(vital energy), Xue and body fluids, identification according to fair principles, identification according to principles of Wei, Qi, Ying and Xue, identification according to Sanjiao(the triple heater), identification according to four type physical constitution. Sometimes, symptoms and diagnosis techniques according to symptoms is selectively applied for the diagnosis. Among them the pulse feeling and palpation diagnosis technique using the sense of finger and palm of the hand is divided into feeling of pulse and palpation and pressing maneuver. Pressing maneuver is a diagnosis technique pressing and rubbing the affected part in order to attain data of identification including inside and outside condition of the body with regard to the nature, condition and relative seriousness of disease. There are palpation of the skin, palpation the hand and foot, palpation the chest and the abdomen, palpation shu points in pressing maneuver. The diagnosis of the Back Shu points is a technique to examine the change of disease condition from pressure ache, spontaneous ache, tension, relaxation, solidification revealed through channels and collaterals. I investigates starting disease and an attack of disease of twelve pulse and pulse condition through the study relative to the substance and technique of pressing maneuver, and adjusts diagnosis techniques of a region for acupuncture and matters to be attended. The conclusions are as follows. 1. The Shu or stream points in which pathogenic factors go are important to medical treatment of dormant diseases like bowels disease, cold symptom complex and insufficiency symptom complex. 2. Disease classified by system is diagnosed by the condition of process part like pro-trusion, cave-in, tension, relaxation, pressure ache through palpating the Shu or stream points, that is pressing upward or downward left and right sides of the backbone process by hands. 3. In real clinic pressing maneuver of one's back side is very important to patient's diagnosis treatment. Thus, pressing maneuver of one's back side have to be done without omission. 4. Diagnosis must be accomplished through the perception about the diversity of diagnosis technique of bowels disease, the exact knowledge about pressing maneuver of one's back side for enlargement of treatment range and rising of treatment rate, and pressing maneuver of the Shu or the stream points.

  • PDF