Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer (성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가)

  • Kim, Woo Chul;Min, Chul Kee;Lee, Suk;Choi, Sang Hyoun;Cho, Kwang Hwan;Jung, Jae Hong;Kim, Eun Seog;Yeo, Seung-Gu;Kwon, Soo-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.167-175
    • /
    • 2014
  • The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.

Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold (온열과 냉의 국소적용에 의한 체표면 온도와 근전도 활동의 변화)

  • Choi, Seok-Ju;Lim, Sang-Wan;Kim, Su-Hyon;Mun, Dal-Ju
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.61-72
    • /
    • 2007
  • INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in $45^{\circ}$ flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level $\alpha$ was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=88.930, P<0.001). Changes of surface temperature of vastus medialis muscle according to heat application were radically increased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=27.267, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=19.774, P<0.001). Changes of sEMG by heat and cold application were no statistical difference. Surface temperature of skeletal muscle after heat and cold application showed significant change for 30 min., but it was found that increase or decrease of surface temperature had not great influence on sEMG activities.

  • PDF

Neck-Collar Fitness According to the Neck Movement of Adult Males - Centered on Neck Surface Changes - (성인(成人) 남자(男子)의 경부(頸部) 동작시(動作時) 밀착형(密着形) 칼라 적합성(適合性)에 관(關)한 연구(硏究) - 경부(頸部) 체표면(體表面) 변화(變化)를 중심(中心)으로 -)

  • Shim, Boo-Ja;Lee, So-Young
    • Journal of Fashion Business
    • /
    • v.5 no.2
    • /
    • pp.49-65
    • /
    • 2001
  • This thesis aims to reveal the unsatisfactory unfitting factors in the tight collars of adult males' dress shirts for the purpose of improving neck-collar fitness. For this study, nine adult males were chosen as the subjects. When the subjects erected their necks upright, the researcher conducted an experiment, using the direct anthropometrical measuring method and the gypsum method by turns, in order to understand neck shapes by way of right-neck lateral flection, left-neck lateral flection, neck flection, neck extension, right neck rotation, and left neck rotation. And then, the propriety of allowances from body surface alteration was verified by analyses through the measurement of wearing comfortableness and clothing pressure in two sorts of ready-made dress shirts, which had different allowances. The consequences of this study are as follows: 1. In length alteration to movement, a decrease was found in the opposite (and an increase in the identical) directions of right-neck lateral flection, left-neck lateral flection, and neck flection movements. Also, when the subjects shook their heads, an increase was seen by 0.42$\sim$0.63cm in neck girth, 0.31$\sim$1.12cm in 3cm-above-the-neck base girth, and 1.16cm in neck extension of 3cm-above-the-neck base girth. 2. As a result of the drafts of surface measurement, the alteration ratios of dimensions and vertical length dropped in the identical directions of the movement, but grew in the opposite directions. A reverse change was shown in horizontal length. The rough widening gaps for making drafts were 0.7cm in front left and right, and 0.2cm in back left and right of 3cm-above-the-neck base girth. On the whole, the space was about 1.8cm, while there was no significant variation between the upright stationary test and the movement test. 3. There were important differences between the two kinds of ready-made dress shirts (Type A: 1cm allowance in neck girth; Type B: 2cm allowance) in clothing pressure and wearing comfortableness. That is, Type A had higher pressure and more uncomfortable sense of wearing. In other words, as clothing pressure and wearing comfortableness are negatively related to each other, Type A's greater clothing pressure led to worse wearing comfortableness.

  • PDF

Influencing of Electrical Stimulation to Cervicothoracic Sympathetic Ganglion on the Temperature Change of Body Surface (경흉교감신경절부의 전기자극의 체표면 체열변화에 미치는 영향)

  • Hwang Tae-Yeun;Park Rae-Joon;Kim Tae-Yul;Kim Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.121-132
    • /
    • 2000
  • This study was carried out to determine the influencing of electrical stimulation to cervicothoracic sympathetic ganglion(CTSG; stellate ganglion) u the sympathetic tone. For the purpose of this study. the stimulation was given to both the interferential current stimulation(ICS: AMF 100Hz) group consisting of 10 person(males 8, females 2) and the transcutaneous nerve electrical stimulation(TENS: 100 Hz) group of 10(males 7, females 3) in the right side of the trachea with probe electrodes. Then. the temperature changes on the surfaces of the forehead. cheek, neck and internal ear of cephalocervix, which is subject to the influence of the cervicothoracic sympathetic ganglion, and the palm. which is the end of the upper limbs. measured before. immediately alter. 10 minutes after and 20 minutes after experiment. The results are summarized as follows. 1. The emergence of remarkable Horner's symptoms which appear due to the changes of the tone of cervicothoracic sympathetic ganglion was not seen. However, in the interferential current stimulation group there were two felt the sense of warmth in the facial region and one person who felt it in the upper limbs, and in the transcutaneous nerve electrical stimulation group there was each one person who felt the sense of warmth in the facial region and in the upper limbs, respectively. Both groups have each one person who felt the sense of oppression in the eyelids. Three persons of the interferential current stimulation group and two persons of the transcutaneous nerve electrical stimulation group have the sense of hoarse voice or numbness in the neck. These are the symptoms that appeared during stimulation, so it is difficult for them to be considered as the direct effects of the changes of the tone of cervicothoracic sympathetic ganglion. 2. The t-test was performed to determine the significance between the right, which is the experimental side, and the left, which is the non-experimental side. Significance between the right, which is the experimental side, and the left, which is the non-experimental side. Significant changes were seen in the necks of the interferential current stimulation group and in the cheeks and internal ears of the transcutaneous nerve electrical stimulation immediately after experiment(P<.05). And the interferential current stimulation group showed a very high significance in the cheeks immediately after experiment and in the necks ten minutes after experiment(p<.01). Therefore, it could be seen that the electrical stimulation had an influencing on the changes of body temperature of the cephalocervix. 3. In both the interferential current stimulation group and the transcutaneous nerve electrical stimulation group, the forecheads, checks and necks of the cephalocervix in the experimental side(right) rather than the non-experimental side(left) had mostly a statistically significant rise in temperature immediately after experiment. The one-way ANOVA was carried out to determine the temperature change of on the surface of the body with the lapse of time; before, immediately after, ten minutes after and tewenty minutes after experiment. But no statistical significance was found from both the right and left sides.

  • PDF

An Ergonomic Study on the Search of Body Surface Area Changed by Movements -In the Lower Trunk and Leg- (동작(動作)에 따른 체표면변화부위(體表面變化部位)의 모색(摸索)에 관한 인간공학적(人間工學的) 연구(硏究) - 하반신(下半身)을 중심(中心)으로 -)

  • Cho, Sung Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.4
    • /
    • pp.608-621
    • /
    • 1993
  • The Purposes of this study were 1)to find the body surface total line and segment line significantly(${\alpha}$=0.05) changed by the leg movement including all movement direction of hip joint, knee joint and ankle joint for the more functional clothing. 2)to classify them into 3 types-expansion type, contraction type, expansion & contraction type, and 3)to identify the characteristics of the body surface length changes. 10 Crosswise and 5 lengthwise body surface total lines and 48 crosswise & 39 lengthwise body surface segment lines of 26 female college students aged from 18 to 24 years were measured directly on the body surface and were analyzed by ANOVA & Multiple Comparison Test (Tukey). The results were as following : Body surface total lines significantly changed were all the body surface total lines except abdoman girth, 1/2thigh girth of lower leg and ankle girth, and these were classified into 3 types : Center front leg line belonged to expansion & contraction type, whereas lateral leg line, legscye girth, and total crotch length belonged to contraction type. The rest belonged to expansion type. Knee girth showed maximum expansion, whereas center front leg line showed maximum contraction. Body surface total lines have shown large expansion crosswise whereas lengthwise they have mainly shown contraction. At least more than one component segment line of each body surface total lines except abdoman girth and ankle girth have shown significant change. Top segment of inner leg line showed maximum expansion. whereas just below top segment of center front leg line showed maximum contraction. Crosswise all the body surface segment lines have shown expansion except inner back segments of thigh girth and 1/2thigh girth of upper leg which have shown contraction. Lengthwise they have shown both expansion and contraction according to the location of front or back, and below or upper 1/2thigh girth line except the component segment lines of lateral leg line, which has shown contraction only.(cf. figure 2. figure 3. and table 2-2).

  • PDF

Preliminary study on absorption characteristic of a human body according to the amount of clothing worn for developing standard test dummy (표준더미 개발을 위한 착의량에 따른 인체의 흡음특성 기초연구)

  • Kim, Yong-Hee;Lee, Sung-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.254-260
    • /
    • 2017
  • The purpose of this study is to evaluate the sound absorption characteristics of a human body according to the amount of clothing worn by using reverberation method measurement method for developing standard test dummy, which can be used for testing absorption of occupied audience chair. Test method was based on the previous study (Conti et al., 2004), each experiment is conducted in the reverberation room and a subject wearing clothes is standing in that chamber. In this experiment, the sound absorption area of each frequency band according to the wearing of various material clothing was measured. As a result of measurements, the average sound absorption area of the whole frequency band was $0.25m^2-0.48m^2$ in case of a subject not wearing outer clothes, and $0.38m^2-0.98m^2$ in case of wearing of outerwear. Polyester tops by showing the maximum value, the highest characteristics in the 800 Hz to 1 kHz band among the rest of fiber materials. The outer jacket made of the wool and cotton materials show a higher absorption area as the frequency increases to the higher frequency band. The change of the sound absorption area according to the clothing amount was divided by the thermal resistance (clo) of the worn clothes and the weight per body surface area.

The Application of 3D Bolus with Neck in the Treatment of Hypopharynx Cancer in VMAT (Hypopharynx Cancer의 VMAT 치료 시 Neck 3D Bolus 적용에 대한 유용성 평가)

  • An, Ye Chan;Kim, Jin Man;Kim, Chan Yang;Kim, Jong Sik;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.41-52
    • /
    • 2020
  • Purpose: To find out the dosimetric usefulness, setup reproducibility and efficiency of applying 3D Bolus by comparing two treatment plans in which Commercial Bolus and 3D Bolus produced by 3D Printing Technology were applied to the neck during VMAT treatment of Hypopahrynx Cancer to evaluate the clinical applicability. Materials and Methods: Based on the CT image of the RANDO phantom to which CB was applied, 3D Bolus were fabricated in the same form. 3D Bolus was printed with a polyurethane acrylate resin with a density of 1.2g/㎤ through the SLA technique using OMG SLA 660 Printer and MaterializeMagics software. Based on two CT images using CB and 3D Bolus, a treatment plan was established assuming VMAT treatment of Hypopharynx Cancer. CBCT images were obtained for each of the two established treatment plans 18 times, and the treatment efficiency was evaluated by measuring the setup time each time. Based on the obtained CBCT image, the adaptive plan was performed through Pinnacle, a computerized treatment planning system, to evaluate target, normal organ dose evaluation, and changes in bolus volume. Results: The setup time for each treatment plan was reduced by an average of 28 sec in the 3D Bolus treatment plan compared to the CB treatment plan. The Bolus Volume change during the pretreatment period was 86.1±2.70㎤ in 83.9㎤ of CB Initial Plan and 99.8±0.46㎤ in 92.2㎤ of 3D Bolus Initial Plan. The change in CTV Min Value was 167.4±19.38cGy in CB Initial Plan 191.6cGy and 149.5±18.27cGy in 3D Bolus Initial Plan 167.3cGy. The change in CTV Mean Value was 228.3±0.38cGy in CB Initial Plan 227.1cGy and 227.7±0.30cGy in 3D Bolus Initial Plan 225.9cGy. The change in PTV Min Value was 74.9±19.47cGy in CB Initial Plan 128.5cGy and 83.2±12.92cGy in 3D Bolus Initial Plan 139.9cGy. The change in PTV Mean Value was 226.2±0.83cGy in CB Initial Plan 225.4cGy and 225.8±0.33cGy in 3D Bolus Initial Plan 224.1cGy. The maximum value for the normal organ spinal cord was the same as 135.6cGy on average each time. Conclusion: From the experimental results of this paper, it was found that the application of 3D Bolus to the irregular body surface is more dosimetrically useful than the application of Commercial Bolus, and the setup reproducibility and efficiency are excellent. If further case studies along with research on the diversity of 3D printing materials are conducted in the future, the application of 3D Bolus in the field of radiation therapy is expected to proceed more actively.

Recommended Methods for Surface Counting to Determine Sites of Red Cell Destruction - A Report by the Panel on Diagnostic Applications of Radioisotopes in Haematology of the International Committee for Standardization in Hematology

  • The Korea Society of Nuclear Medicine The Korea Society of Nuclear Medicine
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.57-62
    • /
    • 1974
  • 이 논문(論文)은 1973년(年) ICSH주최로 열린 panel에서 적혈구파괴(赤血球破壞) 장소(場所)를 결정(決定)하기 위한 생체(生體) 체표계측법(醫表計測法)의 표준화(標準化)에 관(關)한 토론(討論) 결과(結果)를 초록(抄錄)한 것이다. 체표계측(體表計測)은 체외(體外)에서 계측기(計測器)를 이용(利用)하여 각(各) 장기(臟器)에서의 방사표지물질(放射標識物質)의 분포(分布) 및 시간경과(時間經過)에 따른 변화(變化)를 측정(測定)하는 것으로서 $^{51}Cr$를 사용(使用)하여 적혈구수명(赤血球壽命)을 측정(測定)할 때 간(肝), 비(脾), 심장(心臟)의 방사능(放射能)을 계측(計測)한다. 이 방법(方法)은 각(各) 장기(臟器)에서의 적혈구파괴(赤血球破壞)의 정도(程度)를 예측할 수 있다. 특(特)히 용혈성(溶血性) 빈혈환자(貧血患者)에서 비장적출(脾臟摘出) 여부를 결정(決定)하는데 도움이 된다. 이 panel에서는 주(主)로 오차(誤差)의 원인(原因)이 되는 여러가지 요인(要因)에 대(對)하여 토론(討論)하였으며 일반적으로 다음과 같은 것에 의견(意見)의 일치(一致)를 보았다. 즉(卽) 비장(脾臟)의 위치(位置)는 $^{99m}Tc$로 비주사(脾走査)를 실시하여 결정(決定)하는것이 좋고, $^{51}Cr$은 체중(體重) 1kg당 $1.5{\mu}Ci$를 사용하여, 계측기(計測器)는 NaI crystal(직경이 5cm이상, 두께가 3.75cm이상)의 scintillation doctor를 사용하고, 계측(計測)은 $^{51}Cr$로 표지(標識)된 적혈구(赤血球) 주입후(注入後) 15분(分) 이후(以後)에 하고 다음날 계측(計測)한 후(後) 2주(週) 동안에 적어도 6번 계측(計測)한다. Data 처리는 excess count법(法)과 비(脾)와 간(肝)의 비(比)로서하는 것이 좋다.定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던, $^{51}Cr$-표지방법(標識方法)에 있어서의 세가지 변법(變法),

  • PDF

On the Histopathological Changes and Methemoglobinemia to Nitrite Toxicity in the Culture Farms of Eel, Anguilla japonica (참장어(뱀장어) Anguilla japonica 양어장(養魚場)에서의 아질산(亞窒酸) 중독(中毒)에 의한 Methemoglobin증(症)과 병리조직학적(病理組織學的) 변성(變性))

  • Yang, Han-Choon;Chun, Seh-Kyu
    • Journal of fish pathology
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 1991
  • Histopathological changes and methemoglobinemia of the eels (Anguilla japonica) reared at six culture farms in the vicinity of Y$\check{o}$su city were investigated under the conditions of $22.0{\sim}29^{\circ}C$, 4.33~7.33ppm of D.O., pH 6.1~8.2 and 0.03~10.1ppm of nitrite from December, 1989 to June, 1990. All of the eels showed no any abnormal state in action, color and blood, but the eels reared in pH 6.0 had planty of mucus and stickiness on their body surface. Methemoglobin levels were 1.03~9.86% of total erythrocyes in Dec. and 5.05~25.69% in June, and poikilocyte levels were 5.8~30.17% in Dec. and 8.67~74.45% in June. These results indicate the fact that the water management of the culture farms was worse in summer than in winter, even though not good in winter. Hypertrophy was found in the gill, hepatic and kidney tissue of the eels in all the culture farms. In March and June, Fish of all culture farms appeared the detachment of gill lamella epithelium cells, pyknosis and sinusoids of nucleus in the hepatic tissue and hemosiderosis in the kidney tissue. The trend of increase in methemoglobin levels appeared in the fish of culture farms with high nitrite concentration, which didn't appear equally in all the culture farms. However, in the culture farms of pH 6.0, methemoglobin and poikilocyte levels were increased independently of concentration of nitrite, and degeneration in the tissue of the gill, liver and kidney was also appeared.

  • PDF

The usefulness of Forward IMRT for Head and Neck Cancer (두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰)

  • Baek Geum Mun;Kim Dae Sup;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 2003
  • I. Purpose The dose distribution in normal tissues and target lesions is very important in the treatment planning. To make the uniform dose distribution in target lesions, many methods has been used. Especially in the head and neck, the dose inhomogeneity at the skin surface should be corrected. Conventional methods have a limitation in delivering the enough doses to the planning target volume (PTV) with minimized dose to the parotid gland and spinal cord. In this study, we investigated the feasibility and the practical QA methods of the forward IMRT. II. Material and Methods The treatment plan of the forward IMRT with the partial block technique using the dynamic multi-leaf collimator (dMLC) for the patients with the nasopharyngeal cancer was verified using the dose volume histogram (DVH). The films and pinpoint chamber were used for the accurate dose verification. III. Results As a result of verifying the DVH for the 2-D treatment plan with the forward IMRT, the dose to the both parotid gland and spinal cord were reduced. So the forward IMRT could save the normal tissues and optimize the treatment. Forward IMRT can use the 3-D treatment planning system and easily assure the quality, so it is easily accessible comparing with inverse IMRT IV. Conclusion The forward IMRT could make the uniform dose in the PTV while maintaining under the tolerance dose in the normal tissues comparing with the 2-D treatment.

  • PDF