• 제목/요약/키워드: 체온조절

검색결과 121건 처리시간 0.023초

체형특성(體型特性)이 체온조절반응(體溫調節反應) 및 온열쾌적감(溫熱快適感)에 미치는 영향(影響) (Effects of Somatotype Characteristics on Body Temperature Control Reaction & Thermal Sensation)

  • 심부자;유현
    • 패션비즈니스
    • /
    • 제7권1호
    • /
    • pp.27-37
    • /
    • 2003
  • This study is the first part of the research to reveal the effects of somatotype characteristics on body temperature control reaction as well as thermal sensation. Nine healthy female collegians (classified into 3 body types of thin, normal, and obese according to Rohrer index) living in Busan were chosen as the subjects. The following are the results: Significant differences of skin temperature appeared in the parts of epigastrium (thin/normal>obese), anterior forearm (normal>thin/obese), and anterior leg (obese > thin/normal) as well as mean skin temperature. Mean skin temperature temporarily dropped owing to the exercise but tended to recover as time went by. Skin temperature of normal/thin shows higher than obese type. The change of skin temperature was noticed in the order of forehead > epigastrium > anterior forearm > anterior leg > anterior thigh (obese type) ; epigastrium > forehead > anterior forearm > anterior thigh > anterior leg (normal type) ; epigastrium > forehead > anterior forearm > anterior thigh > anterior leg (thin type, before and after exercise); epigastrium > forehead > anterior forearm > anterior leg > anterior thigh (thin type, during exercise). Significant differences were shown in the temperature change inside clothes according to somatotypes. No significant differences were revealed in thermal sensation, moisture sensation, and comfortable sensation according to body types and time.

Brown Adipose Tissue의 열생성 기능과 비만 (Brown Adipose Tissue Thermogenesis and Obesity)

  • 양경미;서정숙
    • 한국식품영양과학회지
    • /
    • 제21권4호
    • /
    • pp.460-470
    • /
    • 1992
  • BAT는 신생아를 비롯하여 동면을 취하는 동물 그리고 설치류에 주로 많은 양이 분포되어 있으며, 세포내지방산을 산화시켜 열을 방출하여 체온조절 및 에너지균형 조절자로서 중요한 역할을 하고 있다. 그러므로 에너지 균형 조절을 통한 체중 조절을 통하여 비만과 밀접한 관련성을 맺고 있는 것으로 보인다. 유전적으로 비만인 실험동물의 경우에는 주로 주위온도, 식이량과 그 구성.성분비 변화와 같은 자극에 대해 민감하게 반응을 일으키지 못해 BAT의 열생성 결함으로 비만이 초래되는 것으로 보인다. 인간의 경우에 있어서는 어느 정도 실험동물의 경우와 비슷한 양상을 보이나, 체내 BAT의 분포량이나 BAT의 연소기질인 지방산의 합성능력 등에 많은 차이점들이 있기 때문에 실험동물의 경우를 인간에게 그대로 적용시킬 수는 없다. 뿐만 아니라 인간을 대상으로 연구하는 데에는 몇가지 문제점들이 있다. 우선 사람의 나이, 성, 실험시작전 영양상태, 스트레스 정도, 유전적 배경 그리고 날씨 에 대한 적응능력에 따라서 열생성 정도가 달라지므로 실험결과에 대한 정확한 해석을 하기가 어렵다. 또한 신생아에 비해서 성인의 경우 BAT의 양이 소량이고 분산되어 있기 때문에 BAT량 결정에 어려움이 있고 열생성 정도와 에너지 소비율과 같이 BAT의 열생성 기준을 나타내는 실험방법에도 많은 문제점이 있는 것으로 나타났다. 그러므로 많은 사람을 대상으로 하여 좀더 정확한 측정방법의 개발을 통해서 열생성에 미치는 타 요인들을 배제 시켜 실험을 하여 소비되는 에너지량을 정확하게 산출하고 BAT의 열생성 기전과 자극원인을 명확히 규명한다면 비만의 치료에 많은 도움을 줄 것으로 생각된다.

  • PDF

침상내 기후와 수면과의 관계 (Thermal Comfort and Sleep under Different Room Temperatures)

  • 이영숙
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.351-365
    • /
    • 1991
  • 본 연구에서는, 수면환경의 열적 쾌적도의 측정방법으로서 생리적 반응 뿐만 아닌 국소자극의 반응에 대한 평가법 (Allesthesial Response)에 의 한 가능성을 제시 하고자 하였다. 피험자는 19세에서 22세의 건강한 독일 여자 대학생 5명이며, 실험은 12월과 1월 독일의 KASSEL에 있는 Marburg대학 연구소의 인공기후실에서 이루어졌다. 사용의복은 면 $100\%$의 잠옷이며, 침구는 메트리스와 Wool 담요(두께 180 mm)를 사용하였다. 국소자극 반응의 온도는 $20.0^{\circ}C,\;22.5^{\circ}C,\;25.0^{\circ}C,\;27.5^{\circ}C,\;30.0^{\circ}C,\;32.5^{\circ}C$의 set가 사용되었으며, 온도자극은 Pottier Thermode type PKE 36 HO2-1 (독일, Peltroil사)로서, 온도의 도달정 밀도는 60내지 90초 동안에 각 자극온도의 변화조절이 가능하였다. 수면환경 온도는 $15^{\circ}C,\;18^{\circ}C,\;21^{\circ}C,\;24^{\circ}C,\;27^{\circ}C$의 다섯 환경으로 조절하였으며, 습도는 RH $45\%$였다. 수면환경 $18^{\circ}C$에서 $24^{\circ}C$까지에서는, 수면전, 수면후 모두, 피험자는 약간의 Hypothermia의 경향을 보였지만 Neutral Situation과 큰 차이는 나타나지 않았다. 수면전과 수면후의 체온조절 반응의 차이가 Allesthesial Response와 국소의 쾌적한 온도 선택의 두 실험결과 모두에서 현저히 나타났다. 생리적 반응의 결과에서도 $18^{\circ}C$에서 $21^{\circ}C$까지의 수면환경이 가장 쾌적하게 나타났다. 또한, 실험결과에서 행동적 온도 조절 반응이 생리적 반응에 앞서 보다 민감하게 이루어짐을 볼 수 있었다

  • PDF

Acetaminophen 속용정의 제제개발 연구 (Research and Development of Acetaminophen Quick-dissolving Tablets)

  • 신현종
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2000년도 춘계학술대회
    • /
    • pp.20-25
    • /
    • 2000
  • 아세트아미노펜(파라세타몰)은 p-aminophenol 유도체로서 (그림 1) 두통, 치통, 신경통 등의 통증에 널리 사용되는 해열진통제인데 아스피린과 같은 정도의 해열 진통 효과를 나타내며, 이것은 중추신경계의 체온조절 중추에 작용하여 피부혈관을 확장함으로써 열의 확산을 증가시키는 해열작용과 시상 및 대뇌피질에의 통각역치를 높여 진통작용을 하는 것으로 추정 된다. 아세트아미노펜은 백색의 결정 또는 결성성 가루로 물에 조금 녹고 메탄올 또는 에탄올에 잘 녹으며 수산화나트륨 시액에 녹고 에텔에는 매우 녹기 어렵다 (표1). 대한약전에서는 정제가, 미국약전에는 캅셀제, 좌제, 경구현탁액제, 발포성 건조시럽, 정제 등이 수재되어 있고, 세계 각국에서 OTC 제품으로 1정당 160mg의 츄잉정까지 판매되고 있다. 그러나, 시판되고 있는 정제등은 붕해되어 용출되는데 오랜시간이 소요되어 대한약전에는 약 30분간에 80%이상의 용출기준이 설정되어 있으며, 독특한 쓴맛 때문에 microencapsulation 한 제피세립을 사용하고 있으나 역시 1 정당 300mg 이상의 확산정이나 속용정은 존재하지 않는다. 이것을 개선하기 위하여 붕해속도가 빠르고 특히 진통효과가 빠르며 물없이 구강내에서 간편히 녹여 복용하거나 또는 씹어서 또는 물과 함께 복용할 수 도 있는 $\ulcorner$알카펜$\lrcorner$ 속용정을 개발하게 되었다 (그림2).

  • PDF

노년층을 위한 스마트 재킷의 개발 및 평가 - 미국 여성을 대상으로 - (Development and Analysis of Smart Jacket for the Elderly -Focused on American Women-)

  • 백경자;수잔 애쉬다운
    • 한국의류산업학회지
    • /
    • 제11권2호
    • /
    • pp.315-325
    • /
    • 2009
  • 본 연구에서는 시판 중인 디바이스를 활용하여 외관에서는 기성복의 스타일을 유지하면서 기능성을 부여한 노년 여성을 위한 스마트 재킷을 개발하였다. 노년기에 접어들면서 시력은 약화되며 효과적인 체온조절도 저하된다. 이에 열과 빛의 기능을 제공하는 연구재킷을 제작하고 노년층 소비자들의 평가를 실시하여 그 수용가능성을 확인하고자 하였다. 재킷에 대한 만족도 평가는 전문가 외관 평가 및 소비자 착용 평가로 실시되었으며 재킷의 피트성, 활동성, 디바이스의 기능성, 수용 가능성 여부 등을 평가하였다. 그 결과, 전반적으로 높은 만족도를 보였으며 노년층에서도 충분히 미적요소와 기능성이 결합된 스마트 의류가 일상복으로 받아들여질 수 있음을 알 수 있었다. 그러나 여전히 스마트 의류의 문제점 중의 하나인 디바이스의 무게를 경량화 할 수 있는 방법이 모색되어야 할 것으로 나타났으며, 이러한 결과가 노년층을 위한 스마트 의복의 가능성과 만족도 향상을 위한 방안을 제시하는 기초 자료가 되기를 바란다.

족부의 냉각과 가온이 행동성 체온조절에 미치는 영향 (Effect of Feet Cooling and Feet Warming on the Behavioral Temperature Regulation)

  • 정운선
    • 한국지역사회생활과학회지
    • /
    • 제18권4호
    • /
    • pp.681-686
    • /
    • 2007
  • This study was conducted to investigate the effects of the thermally different states of human feet on temperature regulation in winter season. Five healthy female students of age 20 volunteered as subjects to participate in the study. Physiological responses such as rectal temperature and skin temperatures as well as subjective responses of thermal comfort and thermal sensation were observed. Preferred clothing and preferred temperature were also evaluated in terms of behavioral temperature regulation. The results obtained through the experiment were statistically analyzed using paired t test. Rectal temperature was decreased greater (p<.01) and mean skin temperature was maintained higher (p<.01) in feet wanning than in feet cooling. Results of preferred clothing were coincident with those of general thermal sensation. There was a higher tendency to prefer temperature in feet wanning than feet cooling in the morning. It was concluded that keeping feet skin temperature lower in the early morning and higher in the late evening would be effective in terms of regulating circadian rhythm of core temperature.

  • PDF

의복의 소재 및 형태가 보온력에 미치는 영향 (The Effectso f Textiles Materials and Wearing Type on the Thermal Insulation Value)

  • 손원교;최정화
    • 한국의류학회지
    • /
    • 제23권8호
    • /
    • pp.1098-1109
    • /
    • 1999
  • This study was to examine the effects of textiles materials and wearing types on the thermal regulation responses of human, Cotton polyester wool silk and rayon were chosen as outerwears and acetate was selected as a lining. Blouse-skirt suits blouse-slacks suits and one-piece dress made of selected textiles were examined by human trials, Tests results were as follows ; 1 When subjects wore vlouse-slacks suits Tmsk was showed the highest value. There was a significant difference on Tmsk(p<0.05) when they wore one-piece dress. The temperature of microclimate inside clothing when subjects wore blouse-slacks suits showed the highest value and one-piece dress and then blouse-skirt suits in order. For blouse-skirt suits clothing without lining showed higher temperature of the back of microclimate inside clothing than clothing with lining except cotton(p<0.1) 2. There were no significant consistency of the increasing rates of thermal insulation of garment at fabric test and human trials among polyesterand silk.

  • PDF

사지말초부의 노출과 보온이 인체의 체온조절에 미치는 영향 (Effects of Exposure and Insulation of the Extremities on the Human Thermoregulation)

  • 정운선;등창심실
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.447-451
    • /
    • 1991
  • Effects of insulation after exposure of the extremities on the temperature regulation in clothed men were studied. Experiment was carried out with six males in a climatic chamber fixed at $10^{\circ}C$, $55\%$ R.H. treated with Type A (face only was exposed) and Type B (face and half of the extremities were exposed). Mean skin temperature fell greater in Type B due to intense vasoconstriction than in Type A. Rectal temperature rose a little in Type B and resumed in Type A without any significant differences in metabolism between two types of clothing. These findings suggest that Type B is more effective in physiological defense to the cold stimuli than Type A at least at $10^{\circ}C$.

  • PDF

2종류의 양말착의행동이 인체생리반응에 미치는 효과 (Effects of Two Kifferent Kinds of Socks on Physiologrical Responses)

  • 김희은;권오경
    • 한국의류학회지
    • /
    • 제23권2호
    • /
    • pp.242-249
    • /
    • 1999
  • The purpose of this study was to investigate two different kinds of socks on physiological responses at an ambient temperature of 35$\pm$1$^{\circ}C$ and relative humidity of 50$\pm$5% Five healthy women wearing normal socks or toes socks participated as the subjects. Rectal temperature skin temperatures sweat rate blood pressure pulse rate and questionnaire wee measured. Rectal temperature skin temperature sweat rate blood pressure pulse rate and questionnaire were measured. Rectal temperature and mean skin temperature were lower after exercise at wearing toes socks . Sweat rate was higher at wearing normal socks and blood pressure and pulse rate were tend to higher at wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks than wearing normal socks but wearing comfort was better at wearing normal socks. These results will be discussed form the viewpoint of thermoregulation AVA(Arterio venous Anastomosis) and count current heat exchange.

  • PDF

30분의 수술전 가온이 고관절 전치환술 노인 환자의 수술중 심부체온, 수축기압, 심박동수, 수술후 전율 및 염증반응에 미치는 효과 (The Effects of 30-Minutes of Pre-Warming on Core Body Temperature, Systolic Blood Pressure, Heart Rate, Postoperative Shivering, and Inflammation Response in Elderly Patients with Total Hip Replacement under Spinal Anesthesia: A Randomized Double-blind Controlled Trial)

  • 천유미;윤혜상
    • 대한간호학회지
    • /
    • 제47권4호
    • /
    • pp.456-466
    • /
    • 2017
  • Purpose: This study was designed to determine the effects of pre-warming on core body temperature (CBT) and hemodynamics from the induction of spinal anesthesia until 30 min postoperatively in surgical patients who undergo total hip replacement under spinal anesthesia. Our goal was to assess postoperative shivering and inflammatory response. Methods: Sixty-two surgical patients were recruited by informed notice. Data for this study were collected at a 1,300-bed university hospital in Incheon, South Korea from January 15 through November 15, 2013. Data on CBT, systemic blood pressure (SBP), and heart rate were measured from arrival in the pre-anesthesia room to 3 hours after the induction of spinal anesthesia. Shivering was measured for 30 minutes post-operatively. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were measured pre-operatively, and 1 and 2 days postoperatively. The 62 patients were randomly allocated to an experimental group (EG), which underwent pre-warming for 30 minutes, or a control group (CG), which did not undergo pre-warming. Results: Analysis of CBT from induction of spinal anesthesia to 3 hours after induction revealed significant interaction between group and time (F=3.85, p=.008). In addition, the incidence of shivering in the EG was lower than that in the CG ($x^2=6.15$, p=.013). However, analyses of SBP, heart rate, CRP, and ESR did not reveal significant interaction between time and group. Conclusion: Pre-warming for 30 minutes is effective in increasing CBT 2 and 3 hours after induction of spinal anesthesia. In addition, pre-warming is effective in decreasing post-operative shivering.