• Title/Summary/Keyword: 철도 시뮬레이션

Search Result 1,037, Processing Time 0.031 seconds

Study on Computational Simulation of a Metro Collision Accident and Improvement of Passive Safety (도시철도 충돌사고 시뮬레이션 및 충돌안전도 개선방안 연구)

  • Jung, Hyun Seung;Son, Seung Wan;Kwon, Tae Soo;Kim, Jin Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.885-892
    • /
    • 2015
  • In this study, we simulate the railway crash accident that occurred at the Sangwangsimni station on the Seoul Metro Line #2, and we propose a solution to minimize the damage. We use LS-DYNA, which is the commercial software employed for collision analysis to perform 1-D and 3-D simulations for the recurrence of accidents. By performing 1-D simulations, we analyze the load, displacement, absorbed energy of the couplers, and acceleration of vehicles, and we evaluate the safety in accidental collisions. By performing 3-D simulations, we analyze the deformation of the car and over-ridding. We propose methods to improve the safety in collisions involving railway vehicles, and we perform collision accident simulations to determine improvements when applying a high-performance energy absorber to the front car.

Analysis of Passenger Refuge Model Using EXODUS Refuge Simulator: Case of the Daegu Underground Station Fire (EXODUS 피난시물레이터를 이용한 대구지하역사화재 승객피난모델분석)

  • Lee, Chang-Hyun;Jang, Yong-Jun;Park, Won-Hee;Kim, Dong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1807-1813
    • /
    • 2007
  • The study aims at analyzing an underground station refuge model using EXODUS, one of the refuge simulation programs. The model for simulation is the Daegu Subway (Joongang-ro station). The details of the accident are referred to as the simulation condition the refuge time of traveling from the $3^{rd}$ basement platform to the $1^{st}$ basement is mainly calculated, with passengers numbering 1,000 including 329 at car 1079, 320 at car 1080, and 360 who are not on board. Reference data is used to set up the position of passengers. CFAST fire simulator is also used, and a fast curve among the $t^2$ growth curves, selected as fire growth scenario. The zone is divided into a total of 24 including 18 at the $3^{rd}$ basement platform and 6 at the $2^{nd}$ basement the $1^{st}$ basement is excluded in the fire simulation, however.

  • PDF

Prediction of Percolation Threshold for Electrical Conductivity of CNT-Reinforced Cement Paste (CNT 보강 시멘트 페이스트의 전기전도에 관한 침투임계점 예측)

  • Lee, Seon Yeol;Kim, Dong Joo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.235-242
    • /
    • 2022
  • The percolation threshold of the CNT-reinforced cement paste is closely related to the optimal CNT amount to maximize the sensing ability of self-sensing concrete. However, the percolation threshold has various values depending on the cement, CNT, and water-to-cement ratio used. In this study, a percolation simulation model was proposed to predict the percolation threshold of the CNT-reinforced cement paste. The proposed model can simulate the percolation according to the amount of CNT using only the properties of CNT and cement, and for this, the concept of the number of aggregated CNT particles was used. The percolation simulation consists of forming a pre-hydrated cement paste model, random dispersion of CNTs, and percolation investigation. The simulation used CNT-reinforced cement paste with a water-cement ratio of 0.4 to 0.6, and the simulated percolation threshold point showed high accuracy with a simulation residual ratio of up to 7.5 % compared to the literature results.

A Study on Power Quality Improvement of Power Conversion System in Centralized-Power Type Electric Railway Vehicle (동력 집중식 철도차량의 전력변환장치 전력품질 향상연구)

  • Kim, Jae-Moon;Yun, Cha-Jung;Lee, Eul-Jae
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.6
    • /
    • pp.559-564
    • /
    • 2010
  • This paper proposes an advanced filter design to improve power quality of a head electric power (HEP) as a power conversion unit in centralized-power type electric railway vehicle. First of all, we have measured waveform of output power of transformer connected HEP to design the filter. Throughout experiment and simulation results, it is estimated that switching technique used HEP is advanced selected harmonic elimination PWM (SHEPWM) and the applied switching frequency is about 300Hz. In this paper, a filter to improve power quality considering estimated parameters is designed. As a result, the reduction of the magnitude of the overall harmonic is achieved and confirmed through simulations.

Enhancing the Performance of Call Center using Simulation (시뮬레이션을 통한 콜센터의 성능 개선)

  • 김윤배;이창헌;김재범;이계신;이병철
    • Journal of the Korea Society for Simulation
    • /
    • v.12 no.4
    • /
    • pp.83-94
    • /
    • 2003
  • Managing a call center is a complex and diverse challenge. Call center becomes a very important contact point and a data ware house for successful CRM. Improving performance of call center is critical and valuable for providing better service. In this study we applied forecasting technique to estimate incoming calls and ProModel based simulation model to enhance performance of a mobile telecommunication company's call center. The simulation study shows reduction in managing cost and better customer's satisfaction.

  • PDF

Comparison of Flow Line Layout and Fixed-Position Layout in a Rail Vehicle Assembly Factory (철도차량 의장공장에서 흐름라인방식과 고정위치형 배치방식의 비교)

  • Moon, Dug Hee;Son, Dong Su;Lee, Young Hoon;Shin, Yang Woo
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.3
    • /
    • pp.117-129
    • /
    • 2018
  • In this paper we will discuss two different layout concepts which can be applied to rail-vehicle assembly factory. The existing system is based on the traditional flow line, and the suggested system is based on the fixed position layout. The main factors which affect on the system performances are the variation of process time, shortage rate of part and the shortage period. Simulation experiments indicate that the fixed position layout is better with respect to the throughput, mean flow time per vehicle and the mean flow time per fleet. Furthermore, the fixed position layout is more robust than the flow line because performance measures are insensitive to the variations of factors.

A Study on TPS based on ATO for Driverless LRT (ATO 자동운전 기반의 무인운전 경전철 TPS에 관한 연구)

  • Lee, Chang Hyung;Lee, Jongwoo
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.609-615
    • /
    • 2012
  • TPS (Train Performance Simulation) based on ATO (Automatic Train Operation) is required for driverless LRT (Light Rail Transit) operation plan instead of typical TPS based on driver operation. In this paper, new TPS model using ATO pattern is proposed and compared with the automatic train operation result in a test line of Seoul Metro Line 6 and in a whole line of Busan-Gimhae LRT. The actual ATO pattern can be very accurately simulated by new TPS model with the introduction of 4 parameters such as commercial braking rate, jerk, station stop profile and grade converted distance. The commercial scheduled time for driverless automatic train operation can be proposed to have "Fast" mode TPS trip time plus 3 seconds/km margin recommended by Korean standard LRT specification in this paper.

Modeling for the Analysis of Rail Potential in the DC Railway Power System (직류전기철도 급전시스템에서 레일전위 해석을 위한 모델링)

  • Cho, Woong-Ki;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.138-146
    • /
    • 2010
  • DC railway power supply system generally uses the running rails as negative-polarity return conductor for traction load current, and the induced rail potential and stay current cause serious problems to any electrified matter in the underground and also safety problems to human body. This paper presents a new algorithm for the analysis of the rail potential and the stray current in DC railway power system operated under independent/parallel power feeding mode. The effect of load current fluctuation during train operation is also calculated by using TPS(Train Performance Simulation) program to analysis the variation of the railway potential and stray current along railway track. Simulation program is developed based on the proposed algorithm and case studies are provided.

Analysis of Aerodynamic Characteristics for determination of tunnel cross section in Honam high speed railway (호남고속철도 터널 단면선정을 위한 공기역학적 특성 분석)

  • Kim, Seon-Hong;Moon, Yeon-Oh;Seok, Jin-Ho;Jo, Hyeong-Jae;Yoo, Ho-Sik;Choi, Jeong-Hwan;Rim, Hyoung-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.313-336
    • /
    • 2007
  • Unlike a conventional railway system, a high-speed rail system experiences various aerodynamic problems in tunnel sections. Trains running at a high speed in a small tunnel, when compared with the open field, face significant air pressure, resulting in reduced operating stability and fast change in pressure inside the tunnel. These phenomena further cause some unexpected problems such as the passengers onboard feeling an aural discomfort and an impulsive noise at the tunnel exit. To solve these problems, this paper introduces analysis of aerodynamic characteristics for determination of tunnel cross section. The optimum cross-section that satisfies the criteria of aural discomfort was reviewed through lots of numerical simulation analysis. Also, the pressure inside the passenger car of a train operating on Kyungbu HSR line was measured, and the pressure inside the tunnel and the micro-pressure waves at tunnel exit were measured at Hwashin 5 Tunnel. At the same time, a test of train operation model was performed and then the measurement results and test results were compared to verify that various parameters used as input conditions for the numerical simulations were appropriate.

  • PDF

The Study on Auxiliary Power Unit for Railroad Car (철도차량용 보조전원장치에 관한 연구)

  • Choi, Yeon-Woo;Lee, Byoung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.69-70
    • /
    • 2016
  • 본 논문에서는 공진형 DC/DC Converter와 Single-Switch Boost Converter 구조를 적용한 철도차량용 보조전원장치를 제안한다. 제안하는 회로는 기존 대비 반도체 소자의 개수 저감 및 반도체 소자의 전압 스트레스를 해당 회로부 입력전압의 1/2 이하로 저감 가능하여 낮은 내압의 반도체 소자를 적용할 수 있다. 150kW급 철도차량용 보조전원장치 회로를 컴퓨터 기반 시뮬레이션을 통해 검증하였다.

  • PDF