• Title/Summary/Keyword: 철근콘크리트건물

Search Result 258, Processing Time 0.025 seconds

A Case Study on Economic Analysis of a Solar Water Heating System and a Ground Source Heat Pump System Applied to a Military Building (군 복지시설의 지열시스템과 태양열시스템 경제성 평가 사례 연구)

  • Lee, Jong-Chan;Park, Young-Ho;Lee, Ghang;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • This study is to analyze the performance of SWH(Solar Water Heating) and GSHP(Ground Source Heat Pump) systems by evaluating their energy efficiency and LCC(Life Cycle Cost) as being applied to the OO hall as a selected building in the Army. The OO hall, used as bathrooms, dining rooms, accommodations and offices, has reinforced concrete structure system with three floors above the ground and one underground, and its total floor area is approximately 2,917$m^2$. Two energy simulations are conducted to predict the yearly cooling and heating energy of the selected building: One is for analysis of an air-conditioning energy consumption using the e-Quest program, and another is for two new-renewable energy facilities as a water heating source using the RETScreen. The installed capacity of two new-renewable energy facilities is determined according to the 5% level of total standard construction cost. As a briefly result, SWH system is more energy-effective than GSHP system. Considering the break-even point, it is expected that SWH can take only 3 years 11 months to pay for itself in savings while the investment of GSHP can be recovered in more than 16 years 6 months.

Analysis of the Wireless Communication Environment in the Narrowed Residential Space for the Fire fighting Operation (소방작전을 위한 협소거주 공간의 무선 통신 환경 분석)

  • Park, Hyun-Ju;Hong, Sang-Beom;Choi, Hyuk-Jo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.242-248
    • /
    • 2017
  • Recently, Population has been concentrated in cities due to rapid economic growth. As a result, urban buildings are becoming more dense, high-rise, and diversified. The shape of these urban buildings increases the risk of fire, accidents and crime. The narrow living space has the characteristic of the unchanged floor. In case of a fire, the living space of the narrow residence is large in the damage because the smoke diffusion rate is fast. The radio wave transmittance and transmission distance of wireless communication used in fire fighting operations vary depending on the type of building materials and buildings. Therefore, this paper analyzes the building materials and structural characteristics of the narrow residential space for efficient fire fighting operations. We have developed a communication environment solution for a narrow residential space for the optimal fire fighting operation through the measurement of the radio wave transmittance and the transmission distance of the wireless communication.

A Study on the Rolling Stock Workshop to Analyze the Contribution to the Modern Korean Architecture (한국근대기 철도공장의 건축적 특성에 관한 연구 -용산공장을 중심으로-)

  • Lee, Sang-Haeng
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.1049-1058
    • /
    • 2009
  • Korea's Rolling stock workshop were established with the introduction of a railway, and became the center of industrial construction in the modern age of Korea. There still exist a lot of Rolling stock workshop buildings in the Youngsan Rolling stock workshop, the representative case of Korean Rolling stock workshop, and especially the study aims to look into modern architectural properties centered on those well-preserved buildings. Korea's Rolling stock workshop were built considering the proper conditions of location such as the neighboring districts from the port to transport vehicles and materials, the place where railroad lines are centralized, the short returning distance of railroad cars for entry and departure, and had the facility layout according to the order of a working process of vehicles, and the unique structure and the section facade shape with proper functions and sizes according to each purpose. In particular, they actively adopted steel-frame structure and reinforced concrete structure, and came to have the initial characteristics of Korea's modern industrial building which is called the structural transition. Therefore, this study aims to highlight the importance of Rolling stock workshop including the Youngsan Rolling stock workshop as industrial architecture heritage in the modern age of Korea.

An Experimental Study on the Reinforcement of Low-Rise RC Structure for Seismic Performance (저층 RC 건물의 내진성능 보강에 관한 실험적 연구)

  • Kim, Dongbaek;Lee, Byeonghoon;Kwon, Soondong;Lee, Induk
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • Nowaday, most of the low-rise concrete structures which have less than five stories were built before the intensified seismic code was established 2005. According to the fact that our country is not a safety zone ay more, studies are need to reinforce the seismic performance of that structures. The basic frame of low-rise structure are consist of beams and columns with partition walls, therefore that are very weak about secondary wave of earthquake because of the high stiffness. The partition wall are consist of open channel for sunlight or ventilation and intermediate wall. The intermediate walls will enhance the stiffness of columns, but will cause shear failure with short column effects because of the reduced effective depth. But we don't have studies and adequate design code for partition wall effects, therefore some more studies are need for these facts.

Inelastic Behavior of Reinforced Concrete Frame Structure with Shear Strength of Masonry Wall (조적벽의 전단강도를 고려한 철근콘크리트골조의 비탄성 거동)

  • Yoon, Tae-Ho;Kang, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4216-4222
    • /
    • 2011
  • In this study the inelastic behavior of the existing school buildings with infilled masonry walls is analysed by pushover method. The shear stiffness and strength of masonry wall is calculated from the prior experimets and verified by inelastic analysis. The height of infilled masonry wall affects the structural behavior. The higher the masonry wall height, the higher the initial shear stiffness and strength of masonry wall. As the cracks are developed, the strength of masonry wall is much decreased. The proposed inelastic analysis method shows similar results with the experiments and can be used as inelastic analysis model of reinforced concrete buildings with infilled masonry walls.

Evaluation on the Deformation Capacity of RC Frame Structure with Strong Column-Weak Beam (강한 기둥-약한 보로 설계된 철근 콘크리트 골조구조의 변형성능 평가에 관한 연구)

  • Seo, Soo-Yeon;Lee, Li-Hyung;Chin, Se-Ok;Choi, Yun-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 2003
  • Recently, the concern for displacement-based design has been increased as a performance based design method in which the deformation capacity of structure becomes so important. In this paper, a process is presented to accurately evaluate the deformation capacity of multistory RC frame structure. In the calculation of drift of frame, the deformation of beam and column as well as the deformation of anchorage and joint are considered. From the comparison between previous test and calculation results, the usefulness of the process is verified. The proposed process is also applied to the multiple story RC frame buildings(5, 10, 15 stories) designed to have strong column-weak beam. The results showed that the deformation capacity of the buildings could be not properly evaluated when deformations of anchorage and joint were ignored.

Analysis of CFT Column-RC Flat Plate Interior Connections under Lateral Load (횡하중을 받는 CFT기둥-RC무량판 접합부의 해석연구)

  • Song, Jin-Kyu;Song, Ho-Bum;Oh, Sang-Won;Kim, Byung-Jo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.867-870
    • /
    • 2008
  • Flat plate system has many advantages, story height reduction, a term of works shortening and changeableness of space, etc. However structures become a tendency of higher stories and when we use RC column, the size of column grow larger. For this reason the use of CFT column is increasing more and more. Accordingly, this study carried out the nonlinear finite element analysis. As a result of analysis moment strength of the connection increased but ductility decreased as the top reinforcement ratio in th effective width increased. And moment strength and ductility of the connection decreased as gravity load ratio decreased. In the case that shearhead length is not more than 0.27m, the effectiveness of shearhead length on the moment strength and ductility of the connection were small relatively to other variables. Initial stiffness and moment strength of connection increased as slab thickness increased

  • PDF

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

A Study on Experimental Analysis of Dynamic properites for Structure and its Application (구조물 동특성의 실험적 해석과 응용기술에 관한 연구 (기계식 주차설비 진동제어))

  • 이홍기;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.40-45
    • /
    • 1993
  • 일반적으로 건물 구조물에 전달되는 기계진동을 감소시키기 위해서 기계와 기초사이에 유연한 방진소자를 삽입하여 기계가진력(exciting force)의 전달 률을 줄인다. 또한 구조물의 고유진동수와 진동원의 가진주파수가 일치할 경 우, 가진주파수를 변화시키거나, 구조물의 동특성을 변화시키는 방법을 사용 한다. 어떠한 방안을 선택하든 효과적이고 정량적인 방진 시스템을 구성하고 구조물의 정확한 진동상태를 예측하기 위해서는 진동원의 가진특성과 구조 물의 동특성에 대한 정보가 요구된다. 일반적으로 방진설계를 위해 필요한 진동원의 가진특성은 제조회사의 사양이나 측정을 통하여 비교적 쉽게 얻을 수 있다. 복합재료, 다양한 경계조건, 복잡한 대형구조물등은 수치해석을 이 용하여 해석적인 방법으로 동특성을 구할 경우, 신뢰성 있는 정보를 얻기에 는 많은 노력이 요구된다. 더우기 현장에서 발생하는 진동문제는 대부분 복 잡하고 시간적으로 시급히 해결해야 하기 때문에 효율적인 절차를 구성하여 구조물의 동특성을 해석하는 방법을 사용할 필요가 있다. 구조물의 동특성은 실험적인 방법을 통하여 구하고 그 외의 필요한 계산들은 해석을 통하여 얻 는 것이 효율적일 수 있다. 실험적 동특성해석은 입력하중에 대한 응답의 크 기와 위상 비를 주파수별로 나타내는 전달함수를 측정하는 방법으로서 가진 장치 및 여러 측정/분석 장비가 필요하며, 철교, 교량, 건물의 철골 및 콘크 리트 슬라브등 다양한 중대형의 구조물을 Signal/Noise비가 좋도록 가진 시 켜야 할 필요성이 있다. 본 연구에서는 이러한 실험적 방법의 현장 적응성과 신뢰성을 확보하기 위해 대형충격기(large impact hammer, max, peak force 약 10000N, time duration 약 20ms)를 제작하고 실험/분석 시스템 및 구조물 의 진동제어를 위한 절차를 Fig.1과 같이 구성하고 이를 철근콘크리트 건물 에 설치한 기계식 주차설비의 진동제어에 적용하였다.force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity value. The results shows

  • PDF

Effects of Seismic Loads with Different Return Period on Residential Building with RC Shear Wall Structure under Construction (주거용 RC 벽식 건물의 시공 중 재현주기에 따른 지진하중의 영향)

  • Choi, Seong-Hyeon;Kim, Jea-Yo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • Even though the structural safety is confirmed in the design stage, the structural safety is not guaranteed in the construction stage because the structural system is not completed. In addition, since the construction period is shorter than the period of use of the building after completion, it is excessive to apply the same seismic load to the construction stage as in the design stage. ASCE 37-14 presents the concept of seismic load reduction factor during construction, but does not provide a clear application method. Therefore, in this study, the seismic load reduced according to the return period was applied to the example model of a residential middle-rise RC building. The construction stage of the example model was divided into five-story units, and seismic load with the change of the return period was applied to the construction stage models to analyze the change of seismic load during construction and to check the sectional performances of structural members. By comparing the design strength ratio of the shear wall at the design stage and the construction stage, the range of seismic load magnitudes that can assure the safety during construction of a residential middle-rise RC building was analyzed in terms of the return period.