• Title/Summary/Keyword: 철근대체

Search Result 154, Processing Time 0.02 seconds

Strength and Durability Characteristics of Low-alkali Mortar for Artificial Reefs Produced by 3D Printers (인공어초 3D 프린터 출력을 위한 저알칼리 모르타르의 강도와 내구성능)

  • Lee, Byung-Jae;Kim, Bong-Kyun;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.67-72
    • /
    • 2022
  • Concrete prevents corrosion of reinforcing bars due to its strong alkalinity. However, in the sea, strong alkali components with a pH of 12 to 13 are eluted, which adversely affects the ecological environment and growth of marine organisms. In this study, the mechanical properties and durability of the low alkali mortar were evaluated for the development of a low alkali mortar for the 3D printed artificial reefs. As a result of evaluation of strength characteristics, the α-35 mixture, which were produced with fly ash, silica fume and α-hemihydrate gypsum, satisfied the strength requirement 27 MPa in terms of compressive strength. As a result of pH measurement, it was found that mixing with alpha-type hemihydrate gypsum resulted in minimizing pH due to the the formation of calcium sulfate instead of calcium hydroxide production. As a result of the chloride ion penetration resistance test, the α-35 mixture exhibited the best performance, 3844C. As a result of measuring the length change over time, the α-35 mixture showed the shrinkage 33.5% less compared to the Plain mix.

Evaluation of Chloride Absorption in GGBS Concrete by Impedance Measurements (임피던스 측정을 통한 GGBS 콘크리트의 염화물 흡수 평가)

  • Kim, Jaehwan;Cho, Han-Min;You, Young-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.230-237
    • /
    • 2022
  • It is essential that service life of reinforced concrete structures in economic and safety aspects should be secured. It is well-known that chloride attack is a typical deterioration mechanism in field concrete structures. To prevent serious accidents like collapse, many studies have been conducted to increase resistance of chloride ingress using concrete mixed with GGBS. The usage of GGBS concrete is nowadays mandatory. Since most concretes in the field are unsaturated, study regarding chloride absorption is necessary, but many studies have focused on the chloride diffusion phenomenon. Methods for evaluating chloride absorption are cost and improper in the field. It is necessary to develop a simple method for evaluating chloride absorption in practice. This study evaluated resistance of chloride ingress in GGBS concretes with impedance measurement and absorption test. From the results, it was confirmed that the contents of absorbed chloride were linearly correlated with the measured electrical resistivities (or conductivities) in the concrete. At the end of the test, the electrical conductivities were 250.8 S/m (w/b=0.4) and 303.1 S/m (w/b=0.6) for PC concretes, and 2.6 S/m (w/b=0.4) and 64.4 S/m (w/b=0.6) for GGBS concretes, respectively. Considering influencing factors for chloride absorption and impedance measurement, chloride ingress into concrete is mainly affected by pore structures due to replacement of GGBS. Especially, formations of pore structure are different with binder, thereby binders should be considered in building reinforced concrete structures exposed to chloride environments.

Irrigation Method of Nutrient Solution Affect Growth and Yield of Paprika 'Veyron' Grown in Rockwool and Phenolic Foam Slabs (Rockwool과 Phenolic Foam 배지에서 양액공급 방법이 프리카(Capsicum annuum) 'Veron'의 생육과 수량에 미치는 영향)

  • Kim, Kwang Soo;Lee, Yong Beum;Hwang, Seung Jae;Jeong, Byoung Ryong;An, Chul Geon
    • Horticultural Science & Technology
    • /
    • v.31 no.2
    • /
    • pp.179-185
    • /
    • 2013
  • This study was carried out to find a reasonable irrigation method of a nutrient solution for the phenolic foam slab (foam LC) used in a trial experiment to substitute the rockwool slab in the production of paprika (Capsicum annuum 'Veyron'). 100, 90, and 80 mL of a nutrient solution was supplied per plant each time when the accumulated radiation reached to 100, $90J{\cdot}cm^{-2}$, and they were named as the 100-100, 90-90, and 90-80 treatment, respectively. The drain percentage per plant of the 100-100 treatment was high by 33.8% in rockwool and 36.7% in foam LC (Lettuce Cube) and that of 90-80 treatment was low by 30.4% and 33.7%. The water content and EC of the rockwool slab were maintained in the range of 63.6-68.9% and $4.4-5.1mS{\cdot}cm^{-1}$, while those of the foam LC slab were in the range of 52.9-58.8% and $5.5-6.5mS{\cdot}cm^{-1}$. The plant height and leaf size of the 100-100 and 90-90 treatments increased in a similar manner, while those of the 90-80 treatment decreased and those of the rockwool were greater than those of the foam LC. The fruit size and weight of the 100-100 and 90-90 treatments were similarly bigger and heavier than those of the 90-80 treatment. The number of fruits harvested per plant was the greatest in the 90-80 treatment with 8 and 8.3 fruits in the rockwool and foam LC. The number of marketable fruits in the rockwool and foam LC was the greatest with 18.1 and 18.2, respectively, in the 90-90 treatment, while that in the 90-80 treatment was 17.2 and 16.8, respectively. The number of unmarketable fruits of the 90-80 treatment was the greatest (1.7-1.8 fruits per plant) in both the rockwool and foam LC, and most of them were small sized or blossom end rot fruits. The yield of the 90-90 treatment was the greatest among the irrigation.

Feasibility Study for the Reconstruction of Jangan Primary School Building (서울 장안초등학교 재건축 계획 설계 연구 요약)

  • Kim, Seung-Je
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.3 no.3
    • /
    • pp.59-70
    • /
    • 1996
  • 장안초등학교는 한국전쟁 이후인 1955년에 개교된 초등학교이다. 처음에는 8학급의 가교사시설에 18학급으로 편성되어 초기부터 시설이 양적으로 부족하였다. 또한 이 지역의 학생수 증가로 거의 매년에 걸쳐 학급수의 증가와 교실증축이 함께 이루어 졌다. 현재 건물의 건립년도를 살펴보면 1965년 6월에 처음 신관 1층 부분이 건설되어 70년대와 80년대에 걸쳐 꾸준히 증축되어 왔으며, 대지 동측의 별관은 1993년 12월에 건설된 새건물로, 학교교사 건물이 30년된 건물과 최근의 건물이 함께 공존하고 있다. 철근콘크리트 건물이 구조적으로는 100년도 견딘다 하지만 실제로는 약 30년이면 콘크리트의 산성화가 가속화되면서 구조적으로 안전하지 못하다는 학설이 인정되어, 최근 30년이 경과된 학교 건축의 재건축이 사회적 문제로 대두되고 있다. 실제로는 25년이상 경과된 건물에서도 구조적인 하자가 발생하는 예 가 많아 교육부에서는 대체로 25년이상 경과된 건물에 대하여 재건축을 실시하고 있다. 장안초등학교는 20년에서 30년 경과된 건물이 많은 부분을 차지하는 관계로 재건축이 실시되는 예이다. 아직까지 사용이 가능하다고 판단되는 건물은 본관의 남측부분의 교사(1983년 증축)과 신관의 우측부분(1985년 9월 23일 증축)과 별관(1993년 12월 14일 신축)교사동을 들수 있다. 때문에 이 부분에 대하여 철거할 것인가 혹은 그대로 사용할 것인가에 대한 의견이 있어, 최종적으로 별관은 그대로 사용하는 것을 원칙으로 하고 본관 남측부분은 가장 마지막 건설시기에 철거하고 신관 우측부분은 규모가 작아 철거하기로 하였다. 학교건축은 다른 일반건물과는 달리 교육이라는 기능을 충분히 발휘할수 있는 공간구성이 필수적이라 할수 있다. 여기서 말하는 교육이란 예전의 주입식 교육이 아니라 21세기를 바라보는 정보화 세계화를 지향하는 교육으로 학생 개개인의 창의성과 자주성을 발휘시킬수 있는 교육이라는 점에 대하여 의견은 없을 것이다. 이러한 교육이란 다양한 교육방법을 전제로 하며 하나의 학년을 하나의 학습그룹으로 생각하는 것은 중요한 출발점이 될 것이다. 한 학년의 그룹을 교대상의 기본으로하여 이러한 그룹에 대하여 일제학습, 그룹학습, 팀티칭, 개별학습이 이루어 질수 있는 공간을 제공하는 점을 본 장안초등학교 기본계획에서 출발점으로 하였다. 물론 학교전체 학생을 콘트롤할 수 있는 교육방법도 존재한다. 선진 외국의 예를 살펴보면 아동의 능력별 교육을 위하여 무학년제(Non-Grade)를 도입하는 경우도 있지만 아직 우리나라에서는 학급단위가 중요시되고 있다. 이 학급단위는 교육단위이면서 생활지도 단위이기도 하다. 이러한 점을 인식하여 학교건축의 간장 기본 단위가 되는 보통교실 계획을 보통교실과 오픈스페이스를 연속시킨 유니트로 계획하여 일제학습, 그룹학습, 팀티칭, 개별학습 등이 이루어 질수 있도록 하였다. 실제로는 36학급을 계획할 경우, 한학년의 6개 학급이 하나의 공통된 공간내에 그룹핑 되는 것이 바람직하지만(제3안의 배치에서 제안하여 보았지만 북측교실, 오픈스페이스의 통로화등의 문제점이 있었다), 그 규모가 너무 커서 3개학급을 하나의 유니트로 하였다. 물론 한학년이 동일한 층에 배치시켜 서로의 관련성을 높게 하였다. 특별교실 계획은 보통교실과의 관련성과 장래 지역개방의 역할을 고려하여 계획하여야 할 것이다. 장안 초등학교의 경우는 별관을 그대로 사용 한다는 조건이 있기 때문에 기존의 편복도 형식의 교실에서는 보통교실 계획의 어려움이 있어 특별 교실동으로 고려하였다. 때문에 지역개방에 대해서는 문제점을 안고 있다. 체육관은 기준령에는 권장시설로 되어 있지만 학교시설에 필수적인 시설이라 생각한다. 체육은 국민건강에 직결되기 때문이다. 또한 체육관 건설은 실외체육 실내체육에 대응할 뿐 아니라 학교 행사등에 유용히 사용되기 때문에 더욱 필요시설이라 할수 있겠다. 또한 지역개방을 위하여 정문 혹은 후문 가까이에 배치시키는 것은 필수적이다. 별관, 체육관, 운동장, 후문측에 12학급용의 단독건물 등의 기본적인 제약조건을 고려하여 배치하자면 자연히 교실동들이 분산되는 결과를 낳게된다. 이러한 각각의 교사동을 A동을 중심으로 구름다리로 연결하여 동선의 불편함을 해소시켰다. 주차장은 후문 가까이에 약 10정도의 주차공간이 확보가능하다. 이외에는 운동장을 사용하는 방법과 체육관의 1층부분을 필로티로 하여 그곳에 20대 정도 주차시키는 방안이 있다. 주차는 많을수록 편리는 하겠지만 제한된 대지에 모두 만족 시켜주기는 불가능하다. 공공용의 주차와 소방에 필요한 동선이 요구된다. 특히 도심주차난을 생각할 때는 차라리 적극적으로 지하주차장을 계획하는 방안이 있을 것이다. 마지막으로 현재 67학급은 초대형 규모로 초등학교 규모로는 적합하지 못하다. 장래를 고려하여 48학급에서 최종적으로 36학급으로 계획하였으나 한동안은 67학급이 그대로 유지될 것으로 보인다. 신설 초등학교가 가까운 시기에 개교될 것을 기대한다.

  • PDF