• 제목/요약/키워드: 천장구조

검색결과 91건 처리시간 0.022초

내화천장구조 적용을 통한 석고보드 활용 확대에 관한 연구 (A Study on the Application of Gypsum Board through the Application of Fire Resistance Ceiling Structure)

  • 최동호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2019
  • Fire resistance ceiling system is the structure of which the ceiling installed under the slave of the structure has the fire resistance performance. Because of having the fire resistance performance, fire resistive coatings on steel beams can be reduced and large span structures can be constructed. So, it have advantages of convenience for construction, shorten for construction time and cost reducing. In foreign country, it is general that one system consisting of slave and ceiling is constructed as a fire resistance system, in these cases, gypsum boards are mostly used as ceiling materials. The purpose of this study was to explain the possibility of expanding the use of gypsum boards by securing fire resistance performance of these ceilings.

  • PDF

다목적 공간의 소음 및 실내음향 제어 (Noise and Rooms Acoustic Control in Multi-Purpose Space)

  • 정정호;김정중;조창근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.42-45
    • /
    • 2008
  • 다목적 공간 및 공연장은 공연 또는 강연을 위한 공간뿐만 아니라 상점, 식당 및 체육 공간 등 다양한 용도의 공간이 인접되고 있다. 다양한 공간이 인접할 경우 기존의 다목적 공연장에서는 발생하지 않았던 다양한 소음 진동 문제들이 발생한다. 본 연구는 강연 및 공연을 위한 다목적 공간 상부에 식당 및 체육 시설로 활용되는 공간이 배치되어 바닥충격음 문제가 발생할 가능성이 있었다. 바닥충격음의 강당으로의 전달을 차단하기 위하여 기본 구조체에 대한 바닥충격음 차단성능을 측정하여 적절한 저감 대책을 수립하였다. 저감대책으로는 상층부 철골 슬래브와 강당의 철골 구조의 구조적 분리, 유연한 마감재 적용, 슬래브로의 충격진동 차단을 위한 제진재 적용, 이중천장 구조 및 천장내부 흡음구조 형성 등의 종합적인 대책을 수립하였다. 이를 통해 경량충격음 및 중량충격음을 효율적으로 차단하였다. 또한 강당 공간은 강연 및 집회의 공간으로 활용될 수 있도록 하기 위하여 적절한 잔향시간 및 음성 명료도 확보가 필요하다. 플러터 에코, 과도한 잔향시간, 음의 사각지대 등을 최소화하기 위하여 측벽 형태 개선, 천장 반사판 형태를 개선하였다. 또한 측벽에서 진동 등의 영향으로 발생되는 떨림현상을 억제하기 위하여 측벽 내부를 흡음재로 충전하는 등의 대책을 수립하여 적용하였다.

  • PDF

건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 - (Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure -)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

국내 학교시설 천장재의 내진성능 분석 (Analysis on the Seismic Performance of Ceiling System in School Buildings)

  • 박성철;조진일;정태환
    • 교육녹색환경연구
    • /
    • 제15권1호
    • /
    • pp.11-18
    • /
    • 2016
  • 본 연구는 학교현장의 안전교육 과정에서 학교시설 비구조재 중 위험도가 상대적으로 높은 천장재의 내진성능을 평가하고 대책방안을 제시하는 것이다. 평가도구의 개발을 위하여 본 연구는 다음과 같은 4단계로 진행되었다. 첫 단계에서는 국내 외의 내진성능평가 가이드라인들을 분석하여 주요 천장재의 구성품목과 각 품목별 평가방법들을 조사하고, 두 번째 단계에서는 문헌조사의 결과를 기반으로 주요 품목들의 내진성능 실태를 면밀하게 조사하였다. 세 번째 단계에서는 조사된 천장재 구조를 정량적으로 평가하여 지반 및 지진의 유형에 따른 적정성을 평가하였다. 마지막으로 국내 학교시설 천장재에서 우선적으로 고려되어야 할 내진성능보강 대책방안을 제시하였다.

조선시대 궁궐건축의 우물천장 구조 종이반자 연구 (Research on Paper Board Banja With Woomul(井) Structure of Royal Palaces in the Joseon Dynasty)

  • 이종서
    • 건축역사연구
    • /
    • 제32권1호
    • /
    • pp.61-72
    • /
    • 2023
  • Korean architecture classifies Banja (the decorated flat of the ceiling visible from the inside) of Royal Palaces into two types: Woomul(water-well, 井) banja, which inserts rectangular wooden board into lattice frame, and paper banja, which applies paper to the flat ceiling. Such classification was established in the 19th century. Before that, Banja was classified according to what was inserted into the lattice frame, either wooden or paper board. At first, the banja that used paper board was widely installed regardless of the purpose or nobility of the building. However, since the 17th century, the use of paper board banja became mostly restricted to Ondol (Korean floor heating system) rooms which are characterized by private usage and the importance of heating, and it was considered inferior to wooden board banja in terms of rank or grace. The contemporary paper banja was mainly installed in low-rank ondol rooms until the late 19th century to early 20th century, when roll-type wallpaper was introduced from the West and the paper banja came to decorate the King's and Queen's bedrooms. The traditional paper board banja benefits heat reservation, reduces the weight of the ceiling, and allows the adjustment of the lattice frame size. Furthermore, it can feature unique artistry if covered with blue, white, or red Neung-hwa-ji (traditional flower pattered paper).

실내공기질 향상을 위한 환경친화형 바닥공조시스템

  • 조동우
    • 대한설비공학회지:설비저널
    • /
    • 제33권8호
    • /
    • pp.32-40
    • /
    • 2004
  • 바닥공조시스템(underfloor air distribution system)은 건물 내에서 공기흐름을 바닥을 통해 조절하는 방식으로 전통적인 천장공조 방식을 대체할 새로운 시스템으로 평가받고 있다. 일반적으로 바닥 공조시스템은 공조기 등에서 송풍되는 공조공기가 억세스 플로어 하부의 바닥공간으로 전달되고 바닥급기구를 통해 실내로 송풍되는 구조를 이루고 있다. 바닥공조시스템의 이점은 전통적인 천장공조 방식에 비해 실내공기의 질(IAQ)이 향상되며 에너지의 절감이 가능하다는 점을 들 수 있다. (중략)

  • PDF

바닥충격음 저감이 가능한 천장 공법 개발 (Development of ceiling construction methods reduced floor impact sound)

  • 김경호;김성훈;류종관;이종인;김용민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

좌굴, 진동, 강도를 고려한 천장크레인의 경량화에 관한 연구 (A Study on the Reduction of Over Head Crane′s Weight Considering Buckling, Vibration and Strength)

  • 홍도관;안찬우
    • 한국항해항만학회지
    • /
    • 제26권3호
    • /
    • pp.317-322
    • /
    • 2002
  • 본 논문은 마그네트 천장크레인 거더에 대한 경량화를 위한 구조최적설계를 수행하였다. 최적화는 ANSYS 소프트웨어를 사용하여 거더의 중량에 대하여 수행되어졌으며, 특히 거더의 상판, 하판, 옆판 그리고 보강판의 두께인 치수에 초점을 맞추었다. 마그네트 크레인의 중량은 처짐, 응력, 고유진동수와 좌굴강도의 제한을 만족하며 약 15%까지 감량되었으며 또한, 구조적인 안전성이 거더의 판넬구조물의 좌굴해석에 의해 입증되었다. 구조최적화로 중량감소에 대해 예로부터 경험적으로 설계된 구조물을 설계하는 것에 매우 유용할 것으로 생각된다. 또한, 본 논문에서는 설계변수들이 목적함수와 상태변수에 미치는 민감도를 평가하였다.

백제 후기 능묘와 능원의 특성 (A Study on the Latter Baekje Dynasty Royal Tombs and Boundary of the Royal Tomb)

  • 김용성
    • 헤리티지:역사와 과학
    • /
    • 제47권2호
    • /
    • pp.68-84
    • /
    • 2014
  • 백제의 능묘는 금강유역으로 천도 후 송산리식의 횡혈식석실묘 ${\rightarrow}$ 남조식의 전실묘 ${\rightarrow}$ 능산리식의 횡혈식석실묘로 변천하였다. 이 변화에서 가장 눈에 띄는 것이 천장 구조의 변화이다. 천장은 궁륭천장(송산리식) ${\rightarrow}$ 터널천장(전실묘와 능산리식 과도기) ${\rightarrow}$ 집지붕천장(능산리식으로 제형, 삼각형, 평천장 세 아류의 형식)으로 변천했다. 이러한 변천과정에서 가장 특징적인 것은 능산리식 횡혈식석실로 이는 백제에서 창출된 특수한 형식이다. 백제의 능묘는 봉분을 중시하지 않아 현저하지 않았다. 이는 개별 능묘를 과시하여 표지하고자 하는 의도보다는 능원의 영역을 중시하는 가족공동체적인 성격이 강화된 것이고 남조의 영향으로 볼 수 있다. 백제의 능원은 백제가 남천한 후 왕가의 능원에서 단독의 독립능원으로 변천한다. 전자는 송산리와 능산리의 능원이고, 후자는 익산의 쌍릉이다. 전자는 완벽한 풍수지리와 함께 남조의 영향으로 볼 수 있고, 후자는 중국이 재통일된 수와 당초의 능원제 영향이다. 왕가의 능원에는 왕릉만 존재하는 것이 아니고 그와 관련된 인물을 배장하였다. 그리고 능원에는 제의시설이 존재했다. 송산리 능원에는 제단이 설치되어 있었는데, 이는 시조묘적인 성격도 가지고 있었을 가능성이 크다. 능산리 능원에는 공동의 능묘에 대해 제의를 시행할 수 있는 노천의 제의 공간이 마련되었고, 이 제의를 담당하면서 선왕에 대한 명복을 빌기 위한 능사가 설치되었다. 이러한 배치나 구조는 신라의 서악동 능원과 아주 유사하다.