• Title/Summary/Keyword: 처짐식

Search Result 151, Processing Time 0.03 seconds

The Practice of Bending Deflection using Non-destructive MOE of Glulam (비파괴 탄성계수를 이용한 집성재의 휨변형 예측)

  • Park, Jun-Chul;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.48-55
    • /
    • 2009
  • In the glulam beam deflection it is necessary to check the reliability of theory formula, because of wood anisotropy and wood qualities (knot, slop of grain). In this experiment, when bending stress occurred on glulam, practice deflection of glulam measuring with AICON DPA-Pro 3D system were compared with prediction deflection calculated as substituting MOE through non-destructive testing and static MOE through bending test in differential equation of deflection curve. MOE using ultrasonic wave tester of laminae, MOE using natural frequencies of longitudinal vibrations ($E_{cu}$, $E_{cf}$), MOE using ultrasonic wave tester of glulam ($E_{gu}$) and MOE using natural frequencies of longitudinal vibrations ($E_{gf}$) were substituted in this experiment. When practice deflection measured by 3D system was compared with prediction deflection calculated with differential equation of deflection curve, within proportional limit the ratio of practice deflection and prediction deflection was similar as 1.12 and 1.14, respectively. Deflection using ultrasonic wave tester was 0.89 and 0.95, Deflection using natural frequencies of longitudinal vibrations was 1.07 and 1.10. The results showed that prediction deflection calculated by substituting using non-destructive MOE of glulam having anisotropy in differential equation of deflection curve was agreed well with practice deflection.

The Shear-Properties of Reinforced Concrete Beams without Web Reinforcement (복부보강이 없는 철근콘크리트보의 전단특성)

  • 문제길;홍익표
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.151-161
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 비교적 짧은 지간의 철근콘크리트 보에서 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 총30개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 전단지간-유효높이의 비, 인장철근량등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도등을 측정하였다. 실험결과로부터 콘크리트의 강도가 커지고 철근량이 많아질수록, 그리고 전단지간이 짧아질수록 철근콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험성과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험성과를 비교 검토하여 그 상관성을 확인하였다.

Comparison Study of Elastic Catenary and Elastic Parabolic Cable Elements (탄성현수선 및 탄성 포물선 케이블 요소의 비교연구)

  • Kim, Dong-Yeong;Song, Yo-Han;Kim, Moon-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.224-227
    • /
    • 2011
  • 케이블구조의 기하학적 비선형해석을 위한 탄성포물선 케이블요소를 제시한다. 탄성현수선 케이블요소에 대한 적합조건과 접선강도행렬을 토대로 장력이 충분히 도입되어 자중에 의한 처짐 형상이 포물선에 가깝다는 가정 하에서 무응력길이를 포함하는 탄성포물선 케이블요소의 비선형 힘-변형관계식과 접선강도 행렬을 구한다. 또한 현(chord)방향으로 두 케이블요소의 등가 공칭장력식을 정의한다. 탄성포물선 케이블 요소의 수치적인 정확성을 확인하기 위하여, 경사진 케이블을 탄성현수선과 탄성포물선 케이블요소로 각각 모델링하여 매개변수 해석을 수행하고 비교, 분석한 결과를 제시한다.

  • PDF

Off-line Control of Machining Error in a Flexible Ball End Milling System (유연 볼 엔드밀에 의한 가공오차의 Off-line 제어)

  • 심충건;양민양
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.468-484
    • /
    • 1992
  • 본 연구에서는 기존의 유연 볼 엔드밀의 절삭력 모델을 바탕으로 자유 곡면의 정삭 가공에서 발생할 수 있는 과대 또는 과소 절삭을 방지하면서 그 가공의 효율성을 높이기 위한 볼 엔드밀의 이송 속도 결정법을 제시하고자 한다. 먼저, 자유 곡면의 가공에서 발생될 수 있는 공구의 처짐에 따른 가공오차에 대하여 볼 엔드밀 공구의 처 짐벡터와 공작물의 공구 접촉점에서의 법선벡터로 표현되는 가공오차(machining error ) 예측 모델식을 유도하였다. 본 가공오차 예측 모델식은 다시 절삭날당 가지는 이 송량의 함수로 전개되어 그 곡면의 주어진 가공 공차(machining tolerance)를 만족시 키는 이송속도를 결정하게 된다.

Determination of Design Moments in Bridges Constructed by Movable Scaffolding System (MSS공법으로 시공되는 교량의 설계 모멘트 결정)

  • 곽효경;손제국
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.3
    • /
    • pp.317-327
    • /
    • 2001
  • In this paper, a relation to calculate design moments for reinforced concrete(RC) bridges constructed by movable scaffolding system(MSS) is introduced. Through the time-dependent analysis of RC bridges considering the construction sequence, the structural responses related to the member forces and deflections are reviewed, and a governing equation for determination of the design moment, which includes the creep deformation, is derived on the basis of the displacement-force condition at every constructuion stage. By using the relation, the design moment and its variation over time can easily be obtained only with the elastic analysis results without additional time-dependent analysis. In addition, correlation studies with the results by rigorous numerical analyses are conducts to verify the applicability of the introduced relation, and a more reasonable guideline for the determination of design moments is proposed on the basis of the obtained moment envelop.

  • PDF

An Experimental Study on Shear Behavior of Steel Fiber-Reinforced Ultra High Performance Concrete Beams (강섬유 보강 초고성능 콘크리트 보의 전단 거동에 관한 실험 연구)

  • Yang, In Hwan;Joh, Changbin;Lee, Jung Woo;Kim, Byung Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.55-64
    • /
    • 2012
  • Experimental investigation on the structural behavior of steel fiber-reinforced ultra high performance concrete (UHPC) beams subjected to shear are presented. Six tests carried out on simply supported I-beams under concentrated loads are presented. The parameters varied were the volume fraction of the fibers (1.0, 1.5 and 2.0%) and shear span-effective depth ratio (2.5, 3.4). The test results indicated that ultimate shear strength increased with increasing fiber volume, and that ultimate shear strength decreased with increasing shear span-effective depth ratio. In addition, applicability of predictive equations for evaluating the ultimate shear strength of steel fiber-reinforced UHPC beams are estimated based on the test results. The comparison between computed values and the experimentally observed values are shown to validate the proposed theoretical equations. It is found that predictions by using AFGC and JSCE recommendations provide the most accurate estimates of shear strength of steel fiber-reinforced UHPC beams.

Performance Evaluation of Structure Strengthening Using Sprayed FRP Technique (분사식 FRP공법을 이용한 구조물 보강 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.126-136
    • /
    • 2009
  • The sprayed FRP strengthening technique is combining the Glass fiber and Polyester resin in open air and spraying randomly at concrete's surface with high-speed compressed air. Then it strengthens the structures with a new technique evaluated the structural performance. We applied it to concrete beam and tested for flexural strength, depended on Korea Standard(KS F 2408). Then based on the result of flexural strength, the properties were proposed that applying to structures. Based on the experiment, we have evaluated structural performance by the experiment. 1/5 scale prestressed concrete I-beam were made by Korean Highway's typical drawing in 1993. With these test results, 49.8% increased in flexural strength, improvement of the behavior of serviceability state, and strengthening was surely effective for controlling deflection and crack of structure. Consequently, it can be summarized that Sprayed FRP technique has prospect to improve the performance of structure.

Study on the Cable Wall System Applied to Reinforced Concrete Exterior (철근콘크리트구조 외장재에 케이블월 시스템 적용에 관한 연구)

  • Park, Hyun-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.579-585
    • /
    • 2017
  • Development of a facade system that can reduce load factor and costs in high-rise building construction is required. The proposed cable wall system is used as a structural support by the glass-cable and can increase openness on lower elevations and the lobby area. Its use in high-rise buildings can reduce construction costs. Without transferring directly a strong initial tension of the cable to the building frame is connected to the steel member and the reinforced concrete structures, by absorbing the initial tension of the cable, it is possible to control the occurrence of a strong concentrated loads to the structure. Comparison of load-displacement test results from the numerical analysis with the test results showed reasonable agreement, Therefore, the proposed numerical results confirm good prediction of cable behavior for the facade system.

Numerical Evaluation of Lateral-Torsional Buckling Strength in I-section Plate Girder Bridges (I-단면 플레이트거더교의 횡비틀림 좌굴강도의 해석적 평가)

  • Park, Yong Myung;Hwang, Soon Young;Park, Jae Bong;Hwang, Min Oh;Choi, Byung H.
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.321-330
    • /
    • 2009
  • This paper presents numerical analysis results for the lateral-torsional buckling (LTB) strength of steel I-girder bridges. Current Korean and AASHTO design specifications for LTB consider the buckling strength of a single girder with both its ends constrained. The I-girder bridges are composed of more than one girder, and the girders are interconnected with intermediate cross-beams or cross-frames. Therefore, it should be required to evaluate the effects of cross-beam stiffness and the interactionof girders on LTB strength. It is also necessary to consider the effects of transverse web stiffeners on LTB strength. By considering these parameters, a series of four-girder systemswere numerically modeled using 3D shell elements to estimate the LTB strength while considering initial imperfections and residual stresses.

A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges (변형률계를 이용한 강재보의 건전도 평가 시스템 개발에 관한 연구)

  • Hahn, Hyun Gyu;Ahn, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.99-109
    • /
    • 2012
  • This study aimed to develop a Structural Health Monitoring System for steel beams in the manner of suggesting and verifying a theoretical formula for displacement estimation using strain gauges, and estimating the loading points and magnitude. According to the results of this study, it was found that when a load of 160kN (56% of the yield load) was applied, the error rate of the deflection obtained with a strain gauge at the point of maximum deflection compared to the deflection measured with a displacement meter was within 2%, and that the estimates of the magnitude and points of load application also showed the error rate of not more than 1%. This suggests that the displacement and load of steel beams can be measured with strain gauges and further, it will enable more cost-effective sensor designing without displacement meter or load cell. The Structural Health Monitoring System program implemented in Lab VIEW gave graded warnings whenever the measured data exceeds the specified range (strength limit state, serviceability limit state, yield strain), and both the serviceability limit state and strength limit state could be simultaneously monitored with strain gauge alone.