• 제목/요약/키워드: 채광창

검색결과 21건 처리시간 0.028초

편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향 (Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions)

  • 술타나 아즈미리;김정태
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.

자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구 (A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting)

  • 차광석;김회서
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권1호
    • /
    • pp.21-28
    • /
    • 1994
  • 기존 상업용빌딩은 실내 시환경 개선의 필요성이 중시됨에 따라서 자연채광과 인공조명을 겸용하는 천장형태에 따른 조명제어 방법으로 전기에너지도 절약하면서 실내의 작업면 조도는 적정조도를 이루게 하는 방안을 찾고자 한다. 이에 본 논문에서는 창 유리의 종류와 실내의 마감색채, 천장타입에 따른 인공조명의 제어방법을 가지고 실험을 하였으며, 실험한 데이터는 실내의 조명설계시 참고할 수 있는 기초적 자료로 제시하고자 했다.

  • PDF

불균일한 휘도를 갖는 창면의 불쾌글레어 평가실험 (An Experiment of Discomfort Glare from Non-uniform Glare Source)

  • 신주영;김정태;김원우
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-9
    • /
    • 2009
  • 자연채광은 건물 재실자에게 시각적 편안함과 쾌적함을 제공하여 건강성을 향상시키며 조명 에너지를 절약할 수 있는 중요한 조명환경 요소이다. 자연광에 의해 발생되는 창면에서의 글레어는 장시간 노출될 시 시각의 저하, 시각적 불쾌감의 원인이 된다. 창면에 의한 불쾌글레어 평가시에는 창면에서 글레어 광원을 어떻게 선별할 것인가가 중요한 문제이다. 기존의 불쾌글레어 평가법을 적용하더라도 글레어 광원을 한정할 방법이 없다. 따라서 본 연구에서는 글레어 광원 선별방법을 모색하기 위하여 불균일한 대광원의 휘도차가 불쾌글레어감에 미치는 영향을 검토하였다. 이를 위하여 $120{\times}120[cm]$의 정사각형 모형창을 제작하였다. 실험변수는 균일과 불균일한 휘도분포의 광원의 휘도비와 광원크기로 선정하였다. 실험방법은 모형창을 3분할한 후, 각기 다른 휘도비를 설정하여, 1[m], 1.5[m], 3[m] 거리에서 불쾌글레어를 평가하도록 하였다. 실험 결과 두 개의 결론을 얻었다. 첫째, 광원의 평균휘도가 증가할수록 불쾌글레어 평가값이 증가하였으며, 둘째, 창면 상부의 천공 부분만을 글레어 광원으로 볼 수 없으며 하부면도 블쾌글레어 평가에 영향을 주는 것으로 나타났다. 본 연구의 결과는 채광창으로부터의 불쾌글레어 평가 시 글레어 광원을 선택하는 기준으로 활용될 수 있을 것이다.

가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가 (Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System)

  • 차광석;조보람
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF

D.I.Y. Modular 방식을 도입한 목재 창 디자인 개발 (Development of the wooden window design implementing D.I.Y. modular system)

  • 김진영;김도연;노양미;박효미
    • 디자인학연구
    • /
    • 제17권4호
    • /
    • pp.401-404
    • /
    • 2004
  • 본 논문은 일반적인 창문의 개념을 혁신적으로 변화시킨 D.I.Y. 목재 창문 시스템 개발에 간한 것이다. 사용자의 필요에 따라 주문 제작이 가능한 D.I.Y. 시스템을 기본으로 다양한 사물의 속성을 나무 프레임을 가진 창과 결합하여, 채광과 환기를 위한 창의 기본적인 기능을 유지하면서 동시에 새로운 심미성을 가진 미래지향적 창 디자인이다. 제한된 규모와 형태 내에서도 사용자의 필요에 의하여 공간의 효율성 증대 및 다양한 기능을 수용할 수 있는 가능성을 제공하여 안에서나 밖에서나 즐거운 시각으로 창을 바라보게 한다. 또한 나무 플임은 모듈로 되어 있으므로 가변성을 고려한 규격화된 부품을 카탈로그와 연계하여 대량 생산 할 수 있는 가능성을 지니고 있다. 미래의 창문은 보기위한 중간매개체 역할 뿐 아니라, 미래지향적인 창의 디자인과 기술을 재정립하여 사용자 스스로 기본 요소들을 조합하고 분리하여 수납공간, 생활 가구 등의 기능이 활용된 개성 있는 Window를 연출 할 수 있는 것이다.

  • PDF

염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구 (A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance)

  • 오명환;심세라;이철성;진경일;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

광튜브와 디쉬형 집광기의 자연채광 성능 예측 및 비교 연구 (A Comparative Study on Daylighting Performance Prediction of Light Tube and Dish Concentrator)

  • 오승진;한현주;천원기
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.124-132
    • /
    • 2012
  • 본 연구에서는 북측창을 가진 강의실 내의 불균형적인 실내 조도차이를 개선하기 위해 두 가지의 자연채광시스템을 적용하였을 경우에 대하여 Photopia를 이용한 성능 시뮬레이션을 수행하였다. 특히, 본 연구에서는 태양고도가 최고 $80^{\circ}$ 이르는 하지에 청천공 상태 하에서의 태양고도에 따른 각 시스템의 배광분포곡선을 구하고 이를 이용하여 실내 조도 등을 분석하였다. 작업면의 경우, 창측과 복도측의 평균 조도차가 1000lx를 초과하였는데 시스템 설치 후에는 그 차이가 상당히 줄어드는 것으로 나타났다. 광튜브 시스템 설치시 906lx에서 603lx로 감소하였으며, 디쉬형 시스템은 308lx까지 줄어들었다. 광튜브의 성능은 태양고도에 영향을 크게 받았으며 디쉬형 집광기는 지속적인 태양추적으로 인하여 태양고도에 관계없이 일정한 성능을 보여주었다.

빛에 의한 치료적 효과 기반의 한국형 치매요양시설의 자연채광 계획 요소에 관한 고찰 (Daylighting Design Factors for Korean Dementia Nursing Homes Based on the Therapeutic Effects of Light)

  • 지수인
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권4호
    • /
    • pp.71-87
    • /
    • 2022
  • Purpose: This study examines the daylighting design factors of Korean dementia nursing homes, in order to realize a therapeutic environment based on the therapeutic effect of light in the rapidly aging trend with an huge increase in the population of dementia in Korea. Methods: Through literature reviews, this study aims to theoretically examine the therapeutic light environment for the elderly with dementia, derive daylighting design factors of Korean dementia nursing homes, and analyze their detailed design factors. Results: The result of this study can be summarized into two points. The first one is that the daylighting design factors reflected in dementia nursing homes are derived into six factors: building layout, windows, glazing, shading devices, spaces, and interior finishings that determine the availability of daylight. The second one is that the detailed daylighting design factors are shown as primary and secondary detailed design factors, and the main values to be considered when applying these factors into dementia nursing homes are analyzed as maximizing daylight availability, optimization of the possibility of therapeutic view, and anti-glare. Implications: The daylighting design factors will contribute to maximizing the availability of daylight, optimizing the possibility of view, and minimizing the glare in the living spaces of dementia nursing homes in Korea.

발전소 터빈건물의 창문 위치에 따른 온도저감 (Temperature Reduction with the Location of Window in a Turbine Building of Power Plant)

  • 하지수;김태권;정경호
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.207-213
    • /
    • 2016
  • 본 연구에서는 화력발전소 터빈 건물의 온도저감 방안을 도출하기 위해 전산유체역학 상용코드인 ANSYS-FLUENT를 이용하여 열유동 해석을 수행하였다. 터빈 건물의 운전층(operating floor)과 탈기기층(deaerator floor)을 검사체적으로 선정하여 모델링을 하였으며 탈기기층에 설치된 기존의 채광창을 활용하여 환기창으로 대체하는 경우에 대해 해석을 수행하였다. 본 연구를 통하여 첫째, 운전층의 온도를 저감하기 위한 방안은 탈기기층의 모든 창문을 열지 않아야 됨을 알았다. 둘째, 탈기기층의 온도를 저감하기 위한 방안으로 탈기기층의 전면부의 창문을 개방하면 탈기기 영역과 크레인 영역은 각각 $1.5^{\circ}C$$1.6^{\circ}C$를 저감할 수 있었고, 탈기기 후면부의 창문을 개방하면 탈기기 영역은 $1.4^{\circ}C$, 크레인 영역은 $0.5^{\circ}C$의 온도를 저감할 수 있었다. 따라서 고온의 탈기기층 전체 영역의 온도를 저감하기 위해서는 탈기기층 전면부의 창문을 개방하는 것이 유리할 것으로 판단된다.

아파트 구조물 설치에 따른 교육환경 일조량 분석 (Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures)

  • 장호식
    • 한국측량학회지
    • /
    • 제30권2호
    • /
    • pp.117-124
    • /
    • 2012
  • 최근에 노후화된 도시정비사업으로 토지의 집약적 이용을 위해 아파트 및 공동주택을 초고층 및 고층 아파트 구조물로 재건축 승인함에 따라 인근 주거지역의 일조권 침해에 따른 사회문제로 대두되고 있다. 특히, 교육시설에 있어서의 일조량 침해에 따른 교육환경 여건은 많은 문제점을 내포하고 있다. 따라서, 본 연구에서는 이러한 교육환경 일조량 분석을 위해 Auto $CAD^{(R)}$ 프로그램을 이용하여 교육시설물에 대하여 3차원 모델링으로 구성하였다. 그리고, 시뮬레이션 기법으로 교육시설에 있어서 창과 운동장을 채광기준면으로 설정하여 태양의 움직임에 따른 진태양시의 일조량을 아침 8:00에서 오후 4:00까지1분 단위로 계산하였다. 또한, 아파트 신축공사 전 후의 피해에 따른 교육시설의 일조환경을 수치화하였고 일영투사법에 의해 제작된 영상과 비교하여 교육환경 일조량을 검증할 수 있었다. 향후 이러한 시뮬레이션 기법을 활용하여 교육환경일조량 분석에 효율적으로 사용될 수 있을 것으로 기대된다.