• Title/Summary/Keyword: 창 면적

Search Result 78, Processing Time 0.021 seconds

Improvement of The Saturation Voltage Characteristics of BJT Using Folded Back Electrode (Folded Back Electrode를 이용한 BJT의 포화전압특성 개선)

  • 김현식;손원소;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.5
    • /
    • pp.15-21
    • /
    • 2004
  • In this paper a new structure of BJT is proposed to improve the saturation voltage characteristics so that it can be used to the low power switching devices. In the case of the conventional finger transistor(FT), the saturation voltage is so high that it dose not satisfy the requirements for the low power device. So the other multi base island transistor(MBIT) is suggested and its saturation voltage is so low in the region of low current that it satisfy the requirement for the low power switching devices, but in region of the high current the saturation voltage tends to increase so that it does not satisfy the requirements for the low power switching devices. So in this paper a new structure of folded back electrode transistor(FBET) is proposed and the characteristics is investigated. When the new structure is applied the emitter area is increased by 35 % so the saturation voltage is reduced by 30 % at the low current region and the contact area is increased by 92 % so the saturation voltage is reduced by totally f % at the high current region with the reduction of 30 % by the increase of the emitter area and the reduction of 7 % by the increase of the emitter contact area.

Evaluation of Lateral Load Resistance and Heating/Cooling/Lighting Energy Performance of a Post-disaster Refugees Housing Using Lightweight composite Panels (경량 복합패널을 활용한 구호주거의 횡하중 저항성능 및 냉난방조명 에너지성능 평가)

  • Hwang, Moon-Young;Lee, Byung-Yun;Kang, Su-Min;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.252-262
    • /
    • 2019
  • Following the earthquake in Gyeongju (2016) and Pohang (2017), South Korea is no longer a safe place for earthquakes. Accordingly, the need for shelters suitable for disaster environments is increasing. In this study, a lightweight composite panel was used to produce post-disaster housing for refugees to compensate for the disadvantages of existing evacuation facilities. For this purpose, an evaluation of structural performance and thermal environment for post-disaster housing for refugees composed of lightweight composite panels was performed. To assess the structural performance, a lateral loading test was conducted on a system made of lightweight composite panels. The specimens consisted of two types, which differed according to the bonding method, as a variable. In addition, the seismic and wind loads were calculated in accordance with KBC 2016 and compared with the experimental results. Regarding the energy performance, optimization of south-facing window planning and window-wall ratio and solar heat gain coefficient were analyzed to minimize heating, cooling, and lighting energy. As a result, the specimens composed of lightweight composite panels will perform sufficiently safely for lateral loads and the optimized window planning will lead to a low-energy operation.

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF

Design of LTPS TFT Level Shifter for System-On-Panel Application (System-On-Panel 적용을 위한 저온 폴리 실리콘 박막 트랜지스터 레벨쉬프터 설계)

  • Lee, Joon-Chang;Jeong, Ju-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.2 s.344
    • /
    • pp.76-83
    • /
    • 2006
  • We proposed a new level shifter circuit architecture. The prposed circuit can provide high output voltage upto 15V by taking 3.3V logic signal compared to the conventional level shifter. The unposed circuit has compatible speed, low power consumption and chip size. We have confirmed the operation by conducting HSPICE simulation.

Efficiency improvement of PFC boost converter by reduction of inductor winding loss (인덕터의 권선손실 저감을 통한 PFC 승압 컨버터의 효율개선)

  • Seo, Eun-Sung;Choi, Seung-Bin;Liang, Dong;Shin, Hwi-Beom
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.303-304
    • /
    • 2015
  • 본 논문에서는 CCM에서 동작하는 PFC 인덕터의 AC 권선 손실에 대하여 분석하고, PFC 승압 컨버터의 효율을 개선하기 위해 인덕터의 AC 권선손실을 저감하는 방법을 제안한다. 제안한 방법은 기존의 단일선 대신 Litz선을 사용하고, 권선의 DC 저항 및 인덕터의 창면적을 고려하여 권선을 설계한다. 제안한 방법을 적용한 인덕터와 기존의 인덕터를 PFC 승압 컨버터에 적용하여 실험적으로 손실을 비교함으로써 PFC 승압 컨버터의 효율이 개선되었음을 보인다.

  • PDF

The Facade Improvement of Complexed Commercial Building Considering Open Signboard - Focused on Commercial district in Chnagwon - (옥외광고물 설치를 고려한 복합상업건물 입면개선 - 창원시 일반상업지구를 중심으로 -)

  • Yu, Jin-Sang;Seo, You-Seok
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.191-202
    • /
    • 2007
  • In these days, open signboard system is controlled by administrative policy and law, but there is no consideration for different types of building. As such, this study aims to propose planning criteria for streetside commercial buildings, such as elevation and mass design of buildings, layout of signboard attached to the building elevation with consideration for streetscape. In mass planning for streetside commercial buildings, the building type with front open space keeps lower open signboard density than the building type directly leading to the street. It is desirable that open signboard of lower floor part is attached by a horizontal type, open signboard of low medium floor part by a projected vertical type, open signboard of high medium floor part and roof part with a minumum attachment of open signboard. As for elevation planning relative to open signboard, it is desirable that an irregular wall type is more useful than a regular wall type to control open signboard. And in all cases, horizontal element facade has a handicap to control the quantity of signboard. If the building has a corner, the piloti should be used in the corner of lower story for smooth circulation of pedestrians and emphasizing the transparency of elevation. Specially, in the case of a round corner, the corner should be emphasized by the composition of high transparent mass.

  • PDF

Analyzing the Spatial Change of Urban Green Spaces with Cell Based Spatial Metrics : A Case Study of Daegu (화소 기반 공간메트릭스를 이용한 도시 녹지의 공간적 변화 분석: 대구시를 사례로)

  • Seo, Hyun-Jin;Jun, Byong-Woon
    • Journal of the Korean association of regional geographers
    • /
    • v.23 no.1
    • /
    • pp.136-150
    • /
    • 2017
  • This study analyzed the spatial change of urban green spaces in Daegu from 1989 to 2009 using cell based spatial metrics. To do so, the conversion process of land covers during the past 20 years was explored using a land cover change detection matrix. The synoptic analysis with a moving window sampling strategy was conducted to quantify cell based spatial metrics related to size, shape, cohesion, and diversity and to explain the spatial change at the local level. Difference maps were then generated by subtracting the 1989 maps of spatial metrics from the 1998 maps and the 1998 maps from the 2009 maps. The gradient analysis was performed to identify the directional change of spatial metrics along an urban development axis in Daegu. The results from this study show that urban green spaces in Daegu during the past 20 years have been gradually fragmented around the new town housing development districts such as Dalseong-gun, Seongseo, and Ansim. Forests were most prominently fragmented in the Hwawon area while most rapidly in the Chilgok area. Grasslands were largely fragmented in many areas due to the decrease in size and cohesion indices and most fragmented in the Ansim area. The spatial pattern of the decreased and fragmented urban green spaces identified by this study can be used as a base data for establishing the environment-friendly urban development strategy in Daegu.

  • PDF

Preparation and characterization of nanoporous monolith with high thermal insulation performance (나노 기공성 단열 실리카 모노리스 제조 및 특성 연구)

  • Choi, Hyun-Muk;Kim, Seong-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • In this study, we synthesized two different silica monoliths by using sol-gel, solvent exchange, surface modification, ambient pressure drying processes, and surfactant-based templating technique followed by calcination process. All of the prepared two silica monoliths showed crack-free appearance with fairly good transparency, and furthermore were confirmed to have extremely high porosity, specific surface area, and mean pore size below 30 nm. The silica aerogel sample exhibited finer and more homogeneous nano-sized pore structure due to spring back effect caused by surface modification, which resulted in better thermal insulation performance. Based on measured thermal conductivities and theoretical relationship, multi-layered glass window system in which silica monolith prepared in this study was inserted as a middle layer was revealed to have superior thermal insulation performance compared to conventional air-inserted glass window system.

Characterization of Reverse Leakage Current Mechanism of Shallow Junction and Extraction of Silicidation Induced Schottky Contact Area for 0.15 ${\mu}{\textrm}{m}$ CMOS Technology Utilizing Cobalt Silicide (코발트 실리사이드 접합을 사용하는 0.15${\mu}{\textrm}{m}$ CMOS Technology에서 얕은 접합에서의 누설 전류 특성 분석과 실리사이드에 의해 발생된 Schottky Contact 면적의 유도)

  • 강근구;장명준;이원창;이희덕
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.10
    • /
    • pp.25-34
    • /
    • 2002
  • In this paper, silicidation induced Schottky contact area was obtained using the current voltage(I-V) characteristics of shallow cobalt silicided p+-n and n+-p junctions. In reverse bias region, Poole-Frenkel barrier lowering influenced predominantly the reverse leakage current, masking thereby the effect of Schottky contact formation. However, Schottky contact was conclusively shown to be the root cause of the modified I-V behavior of n+-p junction in the forward bias region. The increase of leakage current in silicided n+-p diodes is consistent with the formation of Schottky contact via cobalt slicide penetrating into the p-substrate or near to the junction area and generating trap sites. The increase of reverse leakage current is proven to be attributed to the penetration of silicide into depletion region in case of the perimeter intensive n+-p junction. In case of the area intensive n+-p junction, the silicide penetrated near to the depletion region. There is no formation of Schottky contact in case of the p+-n junction where no increase in the leakage current is monitored. The Schottky contact amounting to less than 0.01% of the total junction was extracted by simultaneous characterization of forward and reverse characteristics of silicided n+-p diode.

Variable Cut-off Frequency and Variable Sample Rate Small-Area Multi-Channel Digital Filter for Telemetry System (텔레메트리 시스템을 위한 가변 컷 오프 주파수 및 가변 샘플 레이트 저면적 다채널 디지털 필터 설계)

  • Kim, Ho-keun;Kim, Jong-guk;Kim, Bok-ki;Lee, Nam-sik
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.5
    • /
    • pp.363-369
    • /
    • 2021
  • In this paper, We propose variable cut-off frequency and variable sample rate small-area multi-channel digital filter for telemetry system. Proposed digital filter reduced hardware area by implementing filter banks that can variably use cut-off frequency and sample rate without additional filter banks for an arbitrary cut ratio. In addition, We propose the architecture in which sample rate can variably be selected according to the number of filters that pass through the multiplexer control. By using time division multiplexing (TDM) supported by the finite impulse response (FIR) intellectual property (IP) of Quartus, the proposed digital filter can greatly reduce digital signal processing (DSP) blocks from 80 to 1 compared without TDM. Proposed digital filter calculated order and coefficients using Kaiser window function in Matlab, and implemented using very high speed integrated circuits hardware descryption language (VHDL). After applying to the telemetry system, we confirmed that the proposed digital filter was operating through the experimental results in the test environment.