• Title/Summary/Keyword: 착화실험

Search Result 194, Processing Time 0.02 seconds

Experimental Study on Firing Test of LPI Engine Using Gasoline Fuel for Improving the Production Process at End of line (엔진 착화 라인의 생산성 향상을 위한 LPI 엔진 가솔린 연료 적용성에 대한 실험적 연구)

  • Hwang, In-Goo;Choi, Seong-Won;Myung, Cha-Lee;Park, Sim-Soo;Lee, Jong-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.133-140
    • /
    • 2007
  • The purpose of this study was to evaluate the effects of gasoline fuel to the LPI engine. Firing test bench was used in order to assess the effect on gasoline-injected LPI engine. Gasoline fuel was supplied into the reverse direction(3-4-2-1 cylinder) at 3.0 bar with commercial gasoline fuel pump. Engine test was performed using the firing test mode at end of line. The deviations of excess air ratio of each cylinder and maximum combustion pressure using gasoline fuel were within 0.1 and $1{\sim}2\;bar$. Engine start time was measured with changing coolant temperature at $20^{\circ}C,\;40^{\circ}C,\;80^{\circ}C$, respectively. Residual gasoline volume in the fuel line was measured about 32 cc after firing test and it was less than 2 cc within 10 seconds purging. To simulate the end of line, the residual gasoline in the fuel line was purged during 5 and 10 seconds. Start time of LPI engine with LPG fuel were 0.61 and 0.58 seconds. This work showed that severe problems such as misfiring and liner scuffing were not occurred applying gasoline fuel to LPI engine.

A Study on the Combustion Characteristics of Synthetic Insulation for Building (건축용 합성 단열재의 연소특성에 관한 연구)

  • Kwon, Hyun-Seok;Lee, Si-Young;Kim, Jong-Buk;Yoon, Myoung-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.30-37
    • /
    • 2018
  • This study is an analysis of combustion characteristics of synthetic insulation materials such as houses and warehouses. Using combustion cone calorimeter and SEM, the researching has experimented combustion characteristics of four kinds of materials such as flame retardant styrofoam, general styrofoam, urethane and gypsum board. And analyzed. As a result of the test, the ignition time (TTI) for the thermal insulation material was found at 27 s~43 s, and the flame retardant styrofoam was ignited at the lowest TTI at 27 s and disappears at 28 s. In addition, the maximum heat release rate (peak HRR) and average heat release rate (mean HRR) of each material were expressed in the following order: urethane> flame retardant styrofoam> styrofoam> gypsum board. Also, the total smoke release ($m^2/m^2$) was the largest at $30.798m^2/m^2$ in flame-retardant styrofoam. The general CO concentration of styrofoam was 0.275 kg/kg and the emission concentration was 12.807 kg/kg. The residues showed the highest 0.029 g in the gypsum board among the above materials.

Thermal Characteristics of Living Leaves in Pinus Densiflora with Heat Flux (복사열 증가에 따른 소나무 생엽의 열적특성 분석)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.75-82
    • /
    • 2010
  • To study the combustion characteristics of forest fuel by fire intensity, the experiment of combustion characteristics on Pinus Densiflora living leaves, which is the weakest species to the forest fire, was delivered, using variables of heat flux(25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$). With the equipment of Cone calorimeter, the characteristics of ignition, heat, smoke release, CO and $CO_2$ release, and mass loss were analyzed. Pinus Densiflora living leaves containing moisture of 60.66% were not ignited at the heat flux of variables 25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$. In proportion to the heat flux value, heat release amount and heat release rate reached maximum value rapidly: higher variables came to the maximum by the half rapidity and the maximum value were twice higher than the former lower variables respectively. As for the smoke release, the less heat flux the variable had, the more smoke release it had, due to incomplete combustion. The release amount of CO and $CO_2$ had more maximum value as the heat flux increased and more radiant heat meaned more carbon oxide. When the forest fire breaks out, therefore, a great amount of CO and $CO_2$ will be released by Pinus Densiflora.

Separation and Elution Behavior of Some Iron(Ⅲ)porphyrin Complexes by Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에 의한 Iron(Ⅲ)porphyrin 착화합물들의 분리 및 용리거동에 관한 연구)

  • Chang Hee Kang;In Whan Kim;Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.12
    • /
    • pp.1035-1046
    • /
    • 1993
  • Some iron(III)porphyrin complexes were prepared, and identified by the spectroscopic methods. Elution behavior of iron(III)porphyrin complexes was investigated by reversed-phase HPLC. The optimum conditions for the separation of iron(III)porphyrin complexes were examined with respect to flow rate and mobile phase strength. These complexes were successfully separated on NOVA-PAK $C_{18}$ column using methanol / water(95/5) for $[T_pCF_3PP)Fe(R)]$ and methanol / water (98/2) for $[(P)Fe(C_6F_5)]$ as a mobile phase. It was found that these complexes were largely eluted in an acceptable range of capacity factor value ($0{\leq}logk'{\leq}1$). The dependence of the capacity factor (k') on the volume fraction of water in the binary mobile phase as well as the dependence of k' on the liquid-liquid extraction distribution ratio$(D_c)$ in methanol-water / n-pentadecane extraction system showed a good linearity. It means that the retention of iron(III)porphyrin complexes on NOVA-PAK $C_{18}$ column is largely due to the solvophobic effect. Also, there was a good linear dependence of the capacity factor(k') on the column temperature and enthalpy calculated by van't Hoff plot. From these results, it was confirmed that the retention mechanism of iron(III)porphyrin complexes in reversed-phase liquid chromatography was invariant under the condition of various temperature, and the solvophobic binding process exhibited isoequilibrium behavior.

  • PDF

Effects of Exhaust Gas Recirculation on Power and Thermal Efficiency of Reactivity Controlled Compression Ignition in Different Load Conditions with a 6-L Engine (6 L급 압축착화 기관에서 천연가스-디젤 반응성 조정 연소 시 부하에 따른 배기 재순환율이 출력 및 열효율에 미치는 영향 분석)

  • Lee, Sunyoup;Lee, Seok-Hwan;Kim, Chang-Gi;Lee, Jeong-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.1-10
    • /
    • 2020
  • Reactivity controlled compression ignition (RCCI) combustion is one of dual-fuel combustion systems which can be constructed by early diesel injection during the compression stroke to improve premixing between diesel and air. As a result, RCCI combustion promises low nitrogen oxides (NOx) and smoke emissions comparing to those of general dual-fuel combustion. For this combustion system, to meet the intensified emission regulations without emission after-treatment systems, exhaust gas recirculation (EGR) is necessary to reduce combustion temperature with lean premixed mixture condition. However, since EGR is supplied from the front of turbocharger system, intake pressure and the amount of fresh air supplementation are decreased as increasing EGR rate. For this reason, the effect of various EGR rates on the brake power and thermal efficiency of natural gas/diesel RCCI combustion under two different operating conditions in a 6 L compression ignition engine. Varying EGR rate would influence on the combustion characteristic and boosting condition simultaneously. For the 1,200/29 kW and 1,800 rpm/(lower than) 90 kW conditions, NOx and smoke emissions were controlled lower than the emission regulation of 'Tier-4 final' and the maximum in-cylinder pressure was 160 bar for the indurance of engine system. The results showed that under 1,200 rpm/29 kW condition, there were no changes in brake power and thermal efficiency. On the other hand, under 1,800 rpm condition, brake power and thermal efficieny were decreased from 90 to 65 kW and from 37 to 33 % respectively, because of deceasing intake pressure (from 2.3 to 1.8 bar). Therefore, it is better to supply EGR from the rear of compressor, i.e. low pressure EGR (LP-EGR) system, comparing to high pressure EGR (HP-EGR) for the improvement of RCCI power and thermal efficiency.

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

Heat of Combustion Experiment Based on the Ratio of Moisture Content of Infected and Non-Infected Bursaphelenchus Xylophilus (재선충 감염 소나무와 비 감염 소나무의 수분함유율에 따른 연소열 실험)

  • Kwon, Hyuk;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.443-451
    • /
    • 2021
  • This study compared and analyzed the thermal characteristics based on the ratio of moisture content of infected and non-infected Bursaphelenchus Xylophilus by heat of combustion experiment. The experiment results are as follows. The analysisresult of the ratio of water content shows that 19.92% on average for infected Bursaphelenchus Xylophilus and 26.27% for non-infected which decreases water content as the size of conduction, convection, and radiant heat increases in case of fire. As the vaporization of the moisture content accelerates, the average moisture content is reached, and the result is contrary to the thermal characteristics of the wood that the moisture content is not ignited by a heat source when the moisture content is under 15%. The combustion heat analysis result showed that infected and non-infected Bursaphelenchus Xylophilus had no significant difference in combustion heat at about 3%. However, it shows that combustion heat is higher than other species. In conclusion, decreasing in moisture content based on the increasing conduction, convection, and radiant heat is one of the direct causes of ignition, and the lower the moisture content, the faster the fire spreads.

An experimental study on development of water mist fire-fighting systems for Ro-Ro spaces (Ro-Ro 구역용 미분무 소화설비의 개발을 위한 실험적 연구)

  • Kwark, Ji-Hyun;Kim, Young-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.946-952
    • /
    • 2013
  • Large scale fire tests were conducted to develop water mist nozzles as a component of fixed water- based fire fighting systems for Ro-Ro spaces and special category spaces. Fire scenarios for this system consist of two cases which are for cargo fire in a simulated truck and for passenger vehicle fire, and each case has 3 different tests according to the position between fixed water mist nozzles and fire source. Every experiment proceeded for 30 minutes and acceptance criteria were based on gas temperature, fuel package's damage and ignition of targets. This study primarily dealt with the experimental results of cargo fire and focused on fire suppression capability in accordance with discharge pressure, flow rate and flow characteristics like swirl and penetration of the developed water mist nozzles. It appeared that low pressure water mist nozzles with about 40 L/min were able to control fire occurred in Ro-Ro spaces.