• Title/Summary/Keyword: 착화실험

Search Result 194, Processing Time 0.024 seconds

Effectiveness Analysis of Fire Extinguishing Agents for Metal Waste Fires (금속화재 대응 시 간이소화용구 및 약제의 소화 효과성 분석)

  • Jin-Suk Kwon;Su-Young Kim;Tae-Sun Kim;Tae-Hee Park;Tae-Dong Kim;Min-Young Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.644-655
    • /
    • 2023
  • Purpose: Metal fires occur in metal handling, processing, waste storage plants, etc. It is difficult for firefighters to extinguish metal fires, and it takes a long time, so caution is needed in fire suppression. Method: In this study, current statistics and problems of metal fires were introduced, and then the effectiveness was verified by experiments with using fire extinguishing agents used in Korea. Comparative suppression experiments of 5 different fire extinguishing agents for burning powders of 99.9% magnesium over 150 ㎛ were performed following the metal powder type test method of Class D fire in ISO 7165. Result: 5 fire extinguishing agents are the power types of dry sands and expanded vermiculites most commonly used in Korea, the certified class D fire extinguisher used abroad, and ochers requiring verification, and the liquid silica gel. Conclusion: The results of experiments showed expanded vermiculites were the best metal fire extinguishing agent considering effectiveness, convenience of use, and economical feasibility.

A Study on the Analysis of the Combustion Behavior and Carbonization Pattern of Vinyl Flooring on Which a Real-Scale Combustion Test Was Performed (실물 연소 실험이 진행된 비닐장판의 연소거동 및 탄화 패턴 해석에 관한 연구)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.120-125
    • /
    • 2019
  • A real-scale combustion test was conducted on a vinyl flooring in a divided space, with 50 mL of an inflammable liquid sprayed on it. The combustion behavior of the vinyl flooring was studied in real time, and the carbonization patterns of the surface and cross-sections of the carbonized vinyl floor were analyzed. When the flame ignited by gasoline reached its peak, a continuously flaming region, intermittent flaming region, plume region, etc., were formed. The combustion of 50 mL gasoline on vinyl flooring took 26 s, and a halo pattern was observed. This test involved spraying kerosene evenly on the vinyl flooring and attempting to ignite the flooring using a gas torch, which failed. After the combustion of the vinyl flooring was complete, its carbonized range was measured to be 600 mm in length and 380 mm in width, and the carbonized area was 1000 ㎟. Heat transformed the coated layer of surface of the carbonized vinyl flooring into a carbonized layer, which became harder. The analysis of cross-section of the boundary surface of the carbonized vinyl flooring using a stereoscopic microscope showed that the vinyl flooring was bubbling, and that the white boundary layer at the bottom of the coated layer had disappeared.

Minimum Burning Pressure of Emulsion Explosives (에멀젼폭약의 최소연소압력에 관한 연구)

  • 이승찬;고재순;이영호
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.79-84
    • /
    • 2004
  • It is well accepted that modem emulsion explosives are intrinsically much less sensitive than traditional products such as dynamites or black powder. However, they have still been involved in a significant number of accidental explosions. In October 1975, Canadian Research, Limited's, Energetic Research Laboratory in Quebec exploded. Although explanations for the incident varied, one logical explanation was that the pump used in transporting the emulsion dead headed, thereby turning mechanical work in to frictional heating under a zero flow rate. There is a minimum pressure required for combustion(MBP) to propagate in emulsion explosives. A stable deflagration may lead to a deflagration-to-detonation transition(DDT) in emulsion explosives. Tests were also performed on sensitized sampled consisting of 6 to 21% waters as well as 1 to 11% aluminium powder. It was founded the emulsion explosives consisting of 6% waters had the lowest minimum homing pressure(MBP) of 3 bar, and the 21% waters were unable to achieve sustained homing at pressures as high as 100 bar. The aluminium contained explosives tested here displayed a MBP higher than that of without emulsion. It appears that this test may offer a firm ground for the classification of emulsion explosives in view of the regulating the hazards associated with the various process used for their manufacturing and transport.

A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR (콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구)

  • Han, Bong-Hoon;Seo, Dong-Ho;Kwon, Young-Hee;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.23-32
    • /
    • 2017
  • Foam block, popularized as the self-interior goods, is susceptible to fire since the main material is the polyethylene flammable synthetic resin. However, it is widely used in homes, offices, and multi-use facilities. In order to understand the fire characteristics of the foam block, two kinds of foam blocks sold in the market (non-fire retardant and fire retardant) were evaluated according to standard of KS F 5660-1 (Reaction to fire test). In addition, the hazard analysis of the gas generated by the combustion of the specimen was performed using the FTIR gas analyzer. The cone calorimeter test showed that the ignition and flame combustion of both two specimens were burned as soon as the radiant heat blocking device was removed, and it was confirmed that the flame could become a rapid propagation factor during the fire. The analysis of the combustion gas through the FTIR gas analyzer showed that both the carbon dioxide and carbon monoxide classified as the common combustion gases and the acrolein, ammonia, and hydrogen cyanide causing serious damage to the human body were detected substantially. This study showed that a foam block product has high ignitionability and generates toxic gases. Hence, it is urgently required to establish the standards used for properly classifying the combustion characteristics of the material on the basis of the use conditions of a foam block product and to prepare the standards on the purpose of use.

Changes in Forms of Nitrogen and Phosphorus in Sediment by Growth of Zizania latifolia (줄(Zizania latifolia)의 생장에 의한 저토에서 질소와 인의 형태 변화)

  • Min, Keum-Sook;Kwak, Young-Se;Kim, Joon-Ho
    • The Korean Journal of Ecology
    • /
    • v.28 no.2
    • /
    • pp.93-98
    • /
    • 2005
  • The effects of the presence of a submerged plant, Zizania latifolia, on physico-chemical characteristics, including Eh, pH, and concentrations of nitrogen and phosphorus in the sediments were studied under pot culture condition. It was shown that Eh value at reduced layer of the sediments was higher in the planted pots than in the non-planted. It was also revealed that $NH_4^+-N$ concentration of the sediments in the planted pots was lower than that of the non-planted, which might be due to the uptake by the plants. In contrast, $NO_3^--N$ concentration in the sediment increased in the presence of the plants compared to the non-planted, which might be attributed to oxygen released from the roots to the reduced layer. The concentration of organic phosphorus in the sediments was much higher than that of NAIP at the beginning of the planting experiment. However, at the end of the experiment, it was reversed; NAIP concentration was much higher than that of organic phosphorus, possibly indicating the transformation of organic phosphorus to NAIP during the experimental period. Both concentrations of $NH_4^+-N$ and $PO_4^{3-}-P$ in the overlying and percolated water were lower in the planted pots than in the non-planted. The concentration of $NO_3^--N$ in the percolated water, however, was higher in the planted pots than in the non-planted. The data was discussed with regard to the potential effects of a submerged plant on dynamics of phosphorus and nitrogen in the rhizosphere of the sediment.

The Experimental Studies of Vacuum Residue Combustion in a Small Scale Reactor (소규모 반응로를 이용한 감압 잔사유지 연소실험)

  • Park Ho Young;Kim Young Ju;Kim Tae Hyung;Seo Sang Il
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.268-276
    • /
    • 2005
  • Vacuum Residue (VR) combustion tests were carried out with a 20 kg/hr (fuel feed rate) small scale reactor. The nozzle used was a steam atomized, internal mixing type. Compared to heavy oil, vacuum residue used in this work is extremely high viscous and contains high percentages of sulfur, carbon residue and heavy metals. To ignite atomized VR particles, it was necessary to preheat the reactor, and it has been done with LP gas. The axial and radial gas temperature, major species concentrations and solid sample were analyzed when varying the fuel feed rate. The main reaction zone of atomized VR-air flame in a reactor was anticipated within about 1 m from the burner tip by considering the profiles oi gas temperature, species concentration and particle size measured along with the reactor. At downstream, the thermally, fully developed temperature distribution was obtained. SEM photographs revealed that VR carbon particles collected from the reactor are porous and have many blow-holes on the particle surface.

A Study on Combustion Patterns of Flammable Liquids by Contained Oil Test (담유 실험에 의한 인화성 액체의 연소 패턴 해석에 관한 연구)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.14-20
    • /
    • 2014
  • The purpose of this study is to analyze combustion patterns by filling a specific container with a flammable liquid and performing combustion tests in a divided space. The container used for the test is made of plastic, 20 mm in depth and 150 mm in width. After the liquid was ignited, its combustion process was photographed using a digital camera and video camera. It was found that in the case of benzene, the flame reached its peak at the fastest speed about 60 s while in the case of alcohol, the flame reached its peak at the lowest speed about 360 s, which is approximately six times slower than the benzene. In most cases, when the flame reached its peak, smoke generated was dark as the plastic container and flammable liquid were combusted simultaneously. After completion of the combustion, it was possible to sample oil vapor from all flammable liquids excluding soybean oil as a result of the examination of oil vapor using a crime investigation tube. That is, it can be seen that there is significant difference in flame propagation speed, pattern, etc., depending on the combustible substances.

Characteristics and Risk Assessment of Flame Spreading Over Metal Dust Layers (퇴적금속 분진층을 전파하는 화염의 연소특성과 위험성 평가)

  • Han, Ou-Sup
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • The wide use of metal dusts have been found in industrial field and many dust explosion accidents occur by fire spread of dust layer. In this study, we developed a new experimental device to examine fire and explosion characteristics of the dust layer. Aspects of the burning zone over metals(Mg, Zr, Ta, Ti, etc) and PMMA(Polymethyl methacrylate) dust layers have been investigated experimentally to clarify behaviors (Spread rate and quenching distance) and effects of $N_2$ surrounding gas on the fire spread over metal dust layers. From the experimental result, it was found that the spread rate of metal dusts is larger than PMMA, the dependability of spread rate over the thickness of dust layer is small, and the minimum oxygen concentration of spread flame over Mg dust layer is 3.6-3.7 vol%. Since high correlation between the spread rate and the reciprocal of quenching distance was seen, relative risk prediction in those inflammable parameters can be predicted.

Reduction of hexavalent chromium (Cr(VI)) under acidic conditions during its determination in cement (시멘트 6가 크롬 (Cr(VI))정량분석법에 관한 고찰 - 분석과정에서 Cr(VI) 의 환원에 따른 오차제어-)

  • Moon, Se-Heum;Jeong, Jae-Hong;Lee, Seung-Hoon;Lee, Seung-Heun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.897-900
    • /
    • 2008
  • Some substances of cement could make underestimate concentration of hexavalent chromium(Cr(VI)) as they reduce Cr(VI) to Cr(III) in acidic condition during the determination of Cr(VI) content in cement. The reduction of Cr(VI) increased with elapsed time after acidification in this study. The reduction rate varied with various cements. From our result, we can conclude that simultaneous additions of acid and DPC were required for the accurate measurement of Cr(VI) in cement. The high recovery rate of 94.3 to 106.7% with the simultaneous acid-DPC addition method can also support our conclusion.

  • PDF

The Real Fire Test in Bedroom for the Performance Based Fire Design (성능기반 화재안전설계를 위한 침실 공간에서의 실화재 실험)

  • Kim, Hyung-Jun;Kwon, In-Kyu;Kweon, Oh-Sang;Kim, Heung-Youl;Chae, Seung-Un
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.32-37
    • /
    • 2013
  • For The performance based fire design of the buildings, the fire characteristic such as proceeding and scale of the fire should be figured out but, there is lack of relevant information because of different conditions and difficulties of mock-up test like type of division space, ventilation condition, etc, in buildings. Therefore, in the study, a heal release rate etc, the engineering characteristic data value on the fire is proposed by mock-up fire test for division space in buildings. The mock-up fire test is carried out in a bedroom with 2.4 (L) ${\times}$ 3.6 (W) ${\times}$ 2.4 (H) m model. Initial ignition was started from trash box and the test was carried out for 30 min. As a result of the fire test, flame was broken to outside within 7 min and 50 s after starting the test and the maximum heat release rate was measured as 3,810.6 kW at 9 min and 34 s.