• Title/Summary/Keyword: 차폐복

Search Result 38, Processing Time 0.021 seconds

A Study on the Construction of High Density Concrete for Radiation Shield (방사선 차폐용 고밀도 콘크리트 시공에 관한 연구)

  • 이제방;조용복;변형균;유건철;임병대
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.399-404
    • /
    • 1994
  • Heavyweight(or High density) concrete, which is generally for shiedling structures, differs from normal weight concrete by having a higher density and special compositions to improve its attenuation properties. There are setting 7 Beam Ports around the reactor of the KMRR Project(Korea Multi-purpose Research Reactor) conducted by the KAERI(Korea Atomic Energy Research Institute). High density(p=5.0t/$\textrm{m}^3$) and Heavyweight(p=3.5t/$\textrm{m}^3$) concrete were placed around the Beam Ports in order to shield radiation. This paper was discussed about construction of High density concrete. High density concrete was placed with method of Preplace Aggregate. Coarse metallic aggregate(steel shot) was used. Boron, boron carbide(B4C), was used to capture effctively the neutrom. The mock-up test was carried out. And the consturction of High density concrete was performed successfully.

  • PDF

Dispersion Characteristics of Magnetic Particle/Graphene Hybrid Based on Dispersant and Electromagnetic Interference Shielding Characteristics of Composites (분산제에 따른 자성금속 무전해도금 기반 그래핀 분산 특성 및 복합재의 전자파 차폐 특성 연구)

  • Lee, Kyunbae;Lee, Junsik;Jung, Byung Mun;Lee, Sang Bok;Kim, Taehoon
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.111-116
    • /
    • 2018
  • In this paper, magnetic FeCoNi particles have been grown through electroless plating on the surface of graphene, and then this hybrid material has been dispersed by various surfactants to prepare films. The pyridine surfactant shows the highest dispersability and low surface resistance value (351 Ohm/sq) and the electromagnetic shielding ability at the frequency of 10 GHz. Specially, the evaporation of the pyridine during the drying process could be able to form the internal conductive network and high dispersion of FeCoNi on the surface of graphene.

강자성체를 이용한 연속 가변 토크 제어 전달 기구의 개발

  • Seo, Hyo-Jeong;An, Jae-Yeong;Myeong, Jin-Sol;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.140-140
    • /
    • 2017
  • 4륜 장착 자동차의 토크 전달은 2륜 구동, 4륜 구동 모드를 간단히 전환하는 방식(part time 4WD)과 항시 사륜 구동 모드에서 전후륜의 토크 전달비를 제어하는 방식(AWD, all wheel drive)이 있다. 경제의 발달에 따라서 취미 인구의 확대로 국내에만 180만 명의 R/C car 사용자가 있다. 이 중 2WD-4WD의 전환을 differential lock mechanism으로 구현한 수입산 모델의 가격이 1,000,000원을 호가하지만 가변 제어 방식이 아닌, 정차 후 2-4륜 구동 전환 방식을 적용하고 있으며 상대적으로 내구성이 떨어진다. DC motor의 출력이 늘어나고 배터리의 성능이 좋아진 현재 소형 RC car의 최고 속도는 80 km/h 정도로 빨라졌다. 그러나 마찰 계수가 낮은 노면(실내의 대부분 평활 처리된 복도)에서는 2륜 구동 모드의 활용도가 매우 낮다. 미끄러운 노면에서 후륜 구동 모드로는 oversteer가 발생하여 차량이 스핀하기 쉽고 전륜 구동 모드로는 understeer가 발생하여 제대로 된 코너링이 어렵다. 상시 4륜 구동 모드는 에너지 소모가 크고 전후륜이 tight coupling되어 있는 문제 때문에 일반적인 노면에서 부드러운 코너링이 잘 이루어지지 않는 문제가 있다. 본 연구에서 제안하는 방식은 그림 1와 같이 center shaft의 중간에 영구 자석으로 만들어진 토크 전달용 판이 있고 그 사이에 자계를 차폐할 수 있는 강자성체 셔터를 서보 기구에 연결하여 서보 회전각에 따라서 구동 쪽의 토크가 피구동축으로 전달되는 양을 연속 가변제어할 수 있다. 토크 전달용 판의 차폐 면적에 따른 토크 전달양을 전/후륜 바퀴의 Static torque를 통해 측정하였으며(그림 2), 공중 상태에서 즉 공기저항만을 고려한 상태에서의 RPM 회전수 차이 측정(그림3)을 통해 구동 쪽의 회전수가 피구동축으로 전달되는 양을 측정하여 연속가변 토크 제어 전달 기구의 성능을 확인하였다. 이 기구는 현재 1차적으로는 remote controller의 ch 3(ON/OFF제어 방식)에 연결하여 특정한 양의 토크를 전륜 쪽으로 보낼 수 있도록 구현이 가능하며, ch 2(PID제어 방식)에 연결하여 연속 가변 조절이 가능하도록 구현이 가능하다. 부가적으로 Arduino board를 내장하여 전후륜의 휠센서에서 입력되는 신호를 감지하여 자동적으로 전후륜에 배분되는 토크를 제어할 수 있도록 설계 중에 있다.

  • PDF

A Study on the Design and Chracteristic Analysis for Noise Cut Transformer (NCT 설계 및 특성 분석에 관한 연구)

  • 이재복;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.146-154
    • /
    • 1998
  • Broadband noise with frequency components in the range from several kHz up the tens of MHz is a major obstacle factor in normal operation of the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices such as filter and surge suppressor are used to cut off the noise. But those devices could not disconnected from the power line, so they result in poor common-mode of NCT as well as insulation characteristics as a isolation transformer in addition faraday shielding and proposed analysis model of NCT having tow functions of surge and noise reduction. The simulated and experimental results for the surge suppression characteristics are compared and evaluated for designed protype 1[kVA] NCT.

  • PDF

Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line (축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석)

  • Cho, Yeun-Gyu;Myung, Sung-Ho;Lee, Jae-Bok;Chang, Sug-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1231-1239
    • /
    • 2006
  • In this research magnetic field reduction effect of each passive loop was analyzed by using the scale down models of transmission lines. This paper examined magnetic field reduction effect of the passive loop that will be applied to actual facility through the experiment, which is about double vertical transmission line and horizontal transmission line. Consequently, by confirming the fact that magnetic field reduction effect can be obtained to 50 % by passive loop without reactive compensation, we insured technology about application of passive loop. And the case of 3 turns of loop showed two times reduction effect than that of 1 turns of loop in reducing magnetic field. Vertical passive loop is more efficient than horizontal passive loop in the aspect of reducing magnetic field on double vertical transmission lines. What is more, vertical passive loop showed good effect of reducing magnetic field in a far distance as well as in a short distance.

A Study on the Illumination Environment of Ultrasound Examination Room (초음파 검사실의 조도 환경에 관한 연구)

  • Im, In-Chul;Lee, Hyo-Yeong;An, Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • The purpose of study is provide the basic data for set up proper illuminance of examination room that put purpose of an empirical study basic data about examination environment setting of the ultrasonic examination on design the examination environment of a new ultrasonic examination. As a method, to investigate the ultrasonic environment related to illumination to take a survey on the ultrasonic examination about test object to 48 parts of six units of general hospital in Busan. As a result, All Door + Curtain showed high scores in analyzing the gender, age, examination part in the case of ultrasonic examination room shielding and LED and light source control is required in the case of kind of light source. In the ultrasonic examination environment survey, the illuminance brightness is average 10 Lux which is included illuminance brightness range recommended the WHO and CEC and illuminance brightness of ultrasonic examination waiting room(ultrasonic examination waiting room, corridor) indicate average 300~800 Lux and it satisfied hospital illumination environment more than 300 Lux recommended by KSA 3011. In conclusion, Basic data suggested that improved future ultrasonic examination environment or designed new examination room on the basis of analysis result of general background and ultrasonic examination related to environment factor.

A Study on Perceptions by College Students of Radiology about the Knowledge, Attitudes and Behaviors of Radiation Exposure Management (방사선과 대학생이 방사선피폭관리에 대한 지식, 태도, 행위에 관한 연구)

  • Yeo, Jindong;Ko, Inho;Kim, Hye-Sook
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.79-99
    • /
    • 2015
  • Participants of this study were students of radiology who were attending colleges or universities located in Daegu and Gyeongbuk. This researcher conducted a questionnaire survey of those students from Feb. 3rd to 21st, 2014. The findings of the study can be summarized as follows. 1. Concerning the knowledge of radiation exposure management, the respondents' scores were highest in two items, or 'Materials based on lead or concrete may shield X-rays' and 'The sexual gland is very sensitive to radiation' and lowest in the item which says' 'Occupational radiation exposure dose should not exceed 20mSv a year in average on a 5-year period basis'. 2. The participants' scores for the attitudes of radiation exposure management were higher in two items, or 'Health examination should be made regularly in relation to radiation exposure' and 'Those who work within the area of irradiation should wear protective clothes' and lowest in the item which says 'Radiation exposure dose should be regularly measured for the calibration of the radiation system'. 3. For the behaviors of radiation exposure management, the surveyed students showed highest scores in two items, or 'When irradiating the patient, the radiator should be behind the protective barrier(plate)' and 'It is needed to receive the education of radiation exposure management regularly' While, their score for a behavior described in the item saying 'Before using the radiation system, it is needed to check whether the machine works normally.

A Study on the Self-absorption Correction Method of HPGe Gamma Spectrocopy Analysis System Using Check Source (Check Source를 이용한 HPGe감마핵종분석시스템의 자체흡수 보정방법 연구)

  • Jeong-Soo, Park;Hyo-Jin, Lim;Hyun-Soo, Seo;Da-bin, Jang;Myoung-Joon, Kim;Sang-Bok, Lee;Sung-Min, Ahn
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.523-529
    • /
    • 2022
  • Gamma spectroscopy analysis is widely used for radioactivity analysis, and various factors are required for radioactivity calculations. Among the factors, K3 for each sample significantly influences the results. The previous methods of correcting the self-absorption effect include a computational simulation method and a method that requires making a CRM(certified reference material) identical to the sample medium. However, the above methods have limitations when used in small institutions because they require specialized program utilization skills or high manufacturing costs and large facilities. The aim of this study is to develop a method that can be easily and rapidly applied to radioactivity analysis. After filling the beaker with water, we placed the radiation source in a uniform position and used the measured value as the benchmark. Next, a correction factor was derived based on the difference in the radiation source count of the benchmark and the identically measured sample. For the radiation source, Eu-152, which emits a broad range of energy within the measurement range of gamma rays, and Cs-134 and Cs-137, which are indicator nuclides in environmental radiation analysis, were used. The sample was selected within the density range of 0.26-2.11 g/cm3, and the correction factor was derived by calculating the count difference of each sample compared to the reference value of water. This study presents a faster and more convenient method than the existing research methods for determining the self-absorption effect correction, which has become increasingly necessary.