• 제목/요약/키워드: 차온제어

검색결과 7건 처리시간 0.024초

유량제어방식에 따른 태양열 급탕시스템의 열성능 평가 (Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.

차온제어기의 On-Off 온도설정에 따른 태양열 시스템 열성능 (Thermal Performance of Solar Thermal System by On-Off Differential Temperature of Differential Temperature Controller)

  • 신우철;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.1-8
    • /
    • 2005
  • On-off differential controller is one of the very important components which affect the system performance of the active solar thermal system. In this study, analyses were made regarding the influence of "on-off" setting temperature on the system efficiency and on the electrical consumption by circulation pump. This study was performed by experiment as well as the computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results. As a results, the turn off temperature(${\Delta}T_{off}$) is much more influence than the turn on temperature(${\Delta}T_{on}$) on the system efficiency. It is more clear and sensitivity in winter season. Finally the optimum on-off setting value and the system on-off pattern according to the several different kind of system was also represented.

$OP\DeltaT/OT\DeltaT$ 응답시간 시정수 변화에 따른 영향 분석

  • 윤덕주
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.221-226
    • /
    • 1998
  • 과잉온도 차온(Overtemperature $\Delta$T) 및 과잉출력 차온(Overpower $\Delta$T)트립에 쓰이는 온도 측정계통 총 지연시간은 6초로 구성되며 RTD 우회배관 제거시 4.5초의 RTD 응답시간(일차지연 상수로 가정)과 1.5초의 순수지연시간(전자회로 지연시간 + 그립퍼 풀림시간등)으로 구성된다. 그러나 RTD우회배관 제거전 사고분석을 일차지연상수를 3.5초, 순수지연을 2.5초로 모델링하였으므로 Simulink를 통한 영향분석과 Rack 응답시험 계단파 입력신호의 타당성을 평가하였다. RTD 응답시간은 전형적인 1차 지연요소로 나타내며 계전기나 제어봉 Gripper Release 시간 등은 순수 지연으로 가정하고 분석을 수행하고 기타 지연/지상 필터를 발전소와 동일하게 모델링하여 분석하므로써 발전소에서 일어나는 과도현상을 묘사할 수 있다는 점을 고려할 때 RTD우회배관 제거후 응답시간 지연상수가 바뀌더라도 안전하다는 결론에 도달했다.

  • PDF

지역난방 적용 태양열시스템의 장기 열성능 분석 (Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

지역난방 열사용시설 자동제어시스템 개선을 통한 회수온도 저감 연구 (The Decrease of Return Temperature by Improvement of the Consumer's Control System in District Heating)

  • 하승규;김연홍;이훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.245-251
    • /
    • 2006
  • The main idea of this study is to turn attention on the question of good cooling ability of customer substations in large district heating networks. The main reason for that is based on our experience that the optimization of district heating very often is directed toward production, whereas questions of optimal distribution are neglected if only the necessary load can be supplied and the customer's request for comfort is met. Our view is that low return temperature(operational temperature differences, ${\Delta}T$) in district heating systems is an Important feature for efficient net operation and gives both economic and operational benefits to the district heating supplier Furthermore, it is as well a prerequisite for meeting the customers demand for reliable supply of the heat load. However, in many practical cases we have seen that district heating return temperatures are higher than necessary. Hence, the aim of the study is to propose and verify a method for detection of the most critical consumers of the net and to identify the reasons for resulting high return temperature. From the results, temperature control system is presented as one of the most important reason of high return temperature in DH networks.

  • PDF

전기차용 7kW급 고전압 히터 유로 형상 설계를 위한 열유동 시뮬레이션 (Thermo-Fluid Simulation for Flow Channel Design of 7kW High-Voltage Heater for Electric Vehicles)

  • 손권중
    • 한국융합학회논문지
    • /
    • 제13권3호
    • /
    • pp.191-196
    • /
    • 2022
  • 내연기관 자동차 히터는 연소과정 중에 발생하는 엔진 열을 이용하므로 열원이 추가로 필요치 않지만, 배터리로부터 동력원을 얻는 전기자동차용 히터는 별도의 전열 장치가 요구된다. 지금까지 개발된 전기차용 히터 중에서 냉매를 이용하는 고전압 히터는 효율이 높고 작동 온도 범위가 넓은 장점이 있다. 고전압 히터 내부의 냉각수 유로의 형상은 열교환 성능을 크게 좌우하므로 히터 개발 시 유로 설계는 기술적으로 매우 중요하다. 본 논문에서는 대칭형 서펜타인 유로를 갖는 7kW급 고전압 히터의 유로 형상 설계를 위해 고전압 열유동 시뮬레이션을 수행하였다. 해석결과로부터 입출구간 차압과 차온 및 유로에서의 유동 균일도를 계산하여 히터의 성능을 평가하였다. 도출된 대칭형 서펜타인 유로 설계안은 기존 평행 서펜타인 비해 차압은 높지만, 열교환 성능은 비등하며 저온부가 비교적 넓게 존재하여 제어 회로의 설치 공간으로 활용할 수 있다는 장점이 있다.

온실난방을 위한 태양열 지중 계간축열시스템의 최적 운전 방안 (Optimal Operation Methods of the Seasonal Solar Borehole Thermal Energy Storage System for Heating of a Greenhouse)

  • 김원욱;김용기
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.28-34
    • /
    • 2019
  • 태양열은 지구에서 가장 풍부한 재생에너지 중의 하나이지만, 일반적으로 태양열이 풍부한 계절과 열부하가 큰 계절이 서로 달라 사용에 제한이 있다. 유럽과 캐나다에서는 하절기의 풍부한 태양열을 저장하고 그 열을 동절기 난방부하에 활용하여 에너지를 절감하는 태양열 계간축열시스템을 활용하고 있다. 최근 물탱크방식 및 지중축열방식의 태양열 계간축열시스템이 국내에 소개되어 실증연구가 활발히 진행 중이다. 본 연구에서는 연간 2,164 GJ의 난방부하를 가진 경기도 화성시의 유리온실 1개동에 $2,000m^2$의 평판형 태양열 집열기, $20,000m^2$의 지중 계간축열조를 사용하고 단기축열조를 사용하지 않는 보어홀 방식의 태양열 지중 계간축열시스템을 모델링하여, 운전제어조건에 따른 태양열 이용률을 평가하였다. 시간에 따른 태양열 지중 계간축열시스템의 동적성능예측을 위하여 TRNSYS 18 프로그램을 이용하여 시뮬레이션 하였다. 결과적으로 본 연구에서 제안한 태양열 지중 계간축열시스템은 태양열 집열과 지중 계간축열조 방열에 각각 차온 제어 하였을 때, 5년간 평균 약 60%의 태양열 이용률을 나타내었다. 본 연구에서 제안된 시스템은 태양열 지중 계간축열시스템의 구성과 제어방법을 단순화하고 성능을 확보하였다.