• Title/Summary/Keyword: 집중시간$(T_c)$

Search Result 18, Processing Time 0.032 seconds

Alteration and Mineralization in the Xiaoxinancha Porphyry Copper Deposit, Yianbin, China: Fluid Inclusion and Sulfur Isotope Study (중국 연변 쇼시난차 반암동 광상의 광화작용 및 변질작용: 유체포유물 및 황동위원소 연구)

  • Seong-Taek Yun;Chil-Sup So;Bai-Lu Jin;Chul-Ho Heo;Seung-Jun Youm
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.211-220
    • /
    • 2002
  • The Xiaoxinancha Cu-Au deposit in the Jilin province, located in NNE 800 km of Beijing, is hosted by diorite. The ore mineralization of Xiaoxinancha Cu-Au deposit show a stockwork occurrence that is concentrated on the potassic and phyllic alteration zones. The Xiaoxinancha Cu-Au deposit in the south is being mined with its reserves grading 0.8% Cu, 3.64 g/t Au and 16.8 g/t Ag and in the north, grading 0.63% Cu, 3.80 g/t Au and 6.8 glt Ag. The alteration assemblage occurs as a supergene blanket over deposit. Hydrothermal alteration at the Xiaoxinancha Cu-Au deposit is centered about the stock and was extensively related to the emplacement of the stock. Early hydrothermal alteration was dominantly potassic and followed by propylitic alteration. Chalcocite, often associated with hematite, account for the ore-grade copper, while chalcopyrite, bornite, quartz, epidote, chlorite and calcite constitute the typical gangue assemblage. Other minor opaque phases include pyrite, marcasite, native gold, electrum, hessite, hedleyite, volynskite, galenobismutite, covellite and goethite. Fluid inclusion data indicate that the formation of this porphyry copper deposit is thought to be a result of cooling followed by mixing with dilute and cooler meteoric water with time. In stage II vein, early boiling occurred at 497$^{\circ}$C was succeeded by the occurrence of halite-bearing type III fluid inclusion with homogenization temperature as much as 100$^{\circ}$C lower. The salinities of type 1II fluid inclusion in stage II vein are 54.3 to 66.9 wt.% NaCI + KCI equiv. at 383$^{\circ}$ to 495$^{\circ}$C, indicating the formation depth less than 1 km. Type I cupriferous fluids in stage III vein have the homogenization temperatures and salinity of 168$^{\circ}$ to 365$^{\circ}$C and 1.1 to 9.0 wt.% NaCI equiv. These fluid inclusions in stage III veins were trapped in quartz veins containing highly fractured breccia, indicating the predominance of boiling evidence. This corresponds to hydrostatic pressure of 50 to 80 bars. The $\delta$$^{34}S$ value of sulfide minerals increase slightly with paragenetic time and yield calculated $\delta$$^{34}S_{H2S}$ values of 0.8 to 3.7$\textperthousand$. There is no mineralogical evidence that fugacity of oxygen decreased, and it is thought that the oxygen fugacity of the mineralizing fluids have been buffered through reaction with magnetite. We interpreted the range of the calculated $\delta$$^{34}S_{H2S}$ values for sulfides to represent the incorporation of sulfur from two sources into the Xiaoxinancha Cu-Au hydrothermal fluids: (1) an isotopically light source with a $\delta$$^{34}S$ value of I to 2$\textperthousand$, probably a Mesozoic granitoid related to the ore mineralization. We can infer from the fact that diorite as the host rock in the Xiaoxinancha Cu-Au deposit area intruded plagiogranite; (2) an isotopically heavier source with a $\delta$$^{34}S$ value of > 4.0$\textperthousand$, probably the local porphyry.

A Productivity Analysis of Tower Crane Installation Progress Based on Simulation Technique (시뮬레이션 기반의 타워크레인 설치 생산성 분석)

  • Kim, Yun-Sik;Cho, Jae-Kyong;Kim, Min-Ji;Cho, Kyu-Man;Hyun, Chang-Taek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.33-40
    • /
    • 2010
  • Recently, the scale of construction work has been growing, and buildings are becoming higher. To enable greater efficiency of construction work, the use of vertical transportation equipment has been radically increasing. In this context, many studies have been conducted on tower cranes. While these studies have discussed issues such as the selection of tower cranes, the optimization of locations, and the hoisting time of tower cranes, there has been no research on the installation of tower cranes. As such, the installation of tower cranes on construction sites has been accomplished based on subjective judgment and technical assistance, and the experience of workers in equipment companies. Therefore, this study analyzes the productivity of tower cranes using simulation methodology, and proposes a generalized model of the installation process of tower cranes in order to offer a basic resource that site managers can directly utilize.

Real-time Reservoir Dam Status Evaluation System Using Wireless Sensor Network System (무선 센서 네트워크 시스템을 이용한 실시간 저수지 댐의 상태평가 시스템)

  • Yoo, Chanho;Kim, Seungwook;Hwang, Jungsoon;Na, Gihyuk;You, Kwangho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.41-46
    • /
    • 2018
  • The wireless sensor network system has the advantage of confirming the behavior of the entire facility by improving the disadvantages of conventional monitoring system. As a result, it is widely proposed as safety diagnosis and measurement of structures, water management systems, and management systems for dam structures. However, there is a lack of research that can evaluate the condition of facilities such as safety at the same time as monitoring. In this study, it is proposed a wireless sensor network system which can evaluate the behavior characteristics of facilities and evaluate the safety status for improving the technical disadvantages on conventional monitoring system. The geotechnical risk factors for the reservoir dam facility were evaluated and the limit values for the risk factors causing the failure of the facility were set. In other words, the system was set up so that the risk factors can be measured and the limit status can be evaluated immediately for each factor. In this study, numerical analysis is carried out for seepage and slope stability analysis using the typical cross section for reservoir dams. The stress-porewater coupling finite difference numerical analysis is performed for establishing the limit displacement for reservoir dam structures. It is developed a system that can estimate the time to reach the critical value by regression analysis using the measured datas.

A Study on the Fluctuation and Influential factors of Daily Visitors of Seoul Children′s Grand Park (도시공원 이용자수의 변동특성과 그 영향변인에 관한 연구 -서울 어린이대공원을 대상으로-)

  • 엄붕춘;최준수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.14 no.2
    • /
    • pp.81-90
    • /
    • 1986
  • The full grasp of recreation demand and factors affecting on recreation demand can be very important information for park planning and management. The object-tives of this study are to investigate factors affecting the fluctuation of urban park visitors and to analyze the relationship between these factors and the daily parti-cipations. The results were as follows; 1) The peak of monthly participations comes on May, April, August and October in order. And these months are specified as school picnic period and vacation of school children. 2) In correlation analysis, the variables such as ‘Day of a week(D)’, ‘Monthly mean temp.(T)’and ‘Monthly character(M)’have high correlations with ‘No. of visitors’in order. And it is better to categorize months by its charater(picnic period in school, vacation etc) than by seasons. 3) Candidate regression model were established, as for 1984 log U= 1.51 + 0.64D1 + 0.02T + 0.36W1 - 0.23M4 + 0.003SS + 0.24Ml($R^2$=0.5326) where, U=no. of daily visitors D1 = sunday.ho1iday(1), weekday(0) T=monthly mean temperature($^{\circ}C$) W1= weather (sunny.cloudy(1) , rainy (>5mm)(0)> M4=non vacations and non school picnic period(1) , if not (0) SS=monthly sunshining hours M1=summer vacation(1), if not(0) 4) The most important variable was ‘Day of a week’(sunday.holiday or not). And temperature, weather and monthly charcter(especially picnic period of school and vacation) were in turn, hence ‘Children's grand park’shows the use pattern of park.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Thymus Size and Its Relationship to Perinatal Diseases; Respiratory Distress Syndrome and Intrauterine Growth Retardation (흉선의 크기와 주산기 질환들과의 관계)

  • Chung, Sun Mi;Kim, Woo Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.855-861
    • /
    • 2002
  • Purpose : Thymus size can be affected by several factors and perinatal diseases can be estimated by its size. The purpose of this study was to search for a relationship between cardiothymic/thoracic(CT/T) ratio and perinatal diseases such as neonatal respiratory distress syndrome(RDS) and intrauterine growth retardation(IUGR) by measuring the width of the cardiothymic shadow at the level of the carina and dividing it by the width of the thorax at the costophrenic angles. Methods : A clinical study was conducted on newborn infants with RDS(n=51), IUGR(n=27), and premature rupture of membranes(PROM, n=48), who were admitted at NICU of Catholic University of Daegu from June 2000 to Oct. 2001. CT/T ratio was measured within six hrs of age, at 2-3 days of age, and at 5-7 days of age. Results : CT/T ratios of RDS group, IUGR group, and PROM group were $0.46{\pm}0.07$, $0.32{\pm}0.04$. $0.36{\pm}0.06$, respectively. CT/T ratios of RDS group within 6hrs of age, at 2-3 days of age, and at 5-7 days of age were $0.43{\pm}0.07$, $0.34{\pm}0.06$, $0.25{\pm}0.04$, respectively. There were statistically significances among the RDS group, the IUGR group, and the PROM group and in the RDS group at different times. Regression for gestational age among three groups was not statistically significant but correlation for gestational age in the entire groups was statistically significant. CT/T ratio between normal spontaneous vaginal delivery and c-section among three groups was not statistically significant. CT/T ratios with dexamethasone-treated group and untreated group was not statistically significant. Conclusion : We concluded that thymus size differed significantly in the perinatal diseases such as RDS and IUGR, and so can be used as an early diagnostic tool for perinatal diseases.

Monitoring of Groundwater quality according to groundwater use for agriculture (농업용 지하수 사용에 따른 지하수질 모니터링 평가)

  • Ha, Kyoochul;Ko, Kyung-Seok;Lee, Eunhee;Kim, Sunghyun;Park, Changhui;Kim, Gyoo-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.30-30
    • /
    • 2020
  • 본 연구에서는 여름철에 농업용수(벼농사용)로서 집중적으로 지하수를 사용하는 지역에서 시기별 지하수 사용에 따른 지하수 수질변화를 평가하기 위해 수행되었다. 연구지역은 충남 홍성군 양곡리와 신곡리 일부를 포함하는 면적 2.83 ㎢(283.3 ha)에 해당하는 지역이다. 연구지역 지하수 수질의 공간적 분포 및 시간적 변화 특성 평가를 위하여 2019년 2회(7월, 10월)에 걸쳐 지하수 관정(21개소)에 대하여 조사 및 분석을 수행하였다. 지하수 샘플은 현장에서 온도(T), pH, 용존산소(DO) 및 전기전도도(EC), 산화환원전위(Eh) 등을 측정하였고, 실험실에서 주요 양이온 및 미량원소(Ca, Mg, Na, K, Si, Sr), 음이온(F, Cl, Br, NO2, NO3, PO4, SO4), 알칼리도, 용존 유기탄소(DOC)와 용존 유기물(DOM) 등을 분석하였다. 지하수 수질조사 결과, 전체의 14~15개소(67~71%)가 Ca-HCO3 유형으로 분류되었으며, 다음으로는 Ca-Cl 유형이 4~5개소(19~24%)가 관찰되었다. 얕은 심도의 관정에서 상대적으로 심도가 깊은 관정보다 대부분 성분(TDS, Ca, Mg, Na, K, Cl, SO4, HCO3, DOC)에서 높은 농도를 나타내었다. 지하수의 수질자료를 이용하여 다변량통계분석법인 주성분분석(PCA: Principal Components Analysis)과 계층적 군집분석(HCA: Hierachical Cluster Anlaysis)를 수행한 결과, 초기 3개 주요 고유성분(eigenvalue)는 PC1 54.0%, PC2 14.2%, PC3 12.3%로 전체 분산의 88.3%를 설명할 수 있었다. PC1은 Ca, Mg, Na, K, Cl, SO4, DOC가 주요한 영향 인자였으며 PC2는 HCO3, NO3, DO에 영향 받음을 확인하였다. 계층적 군집분석 결과, 연구지역 지하수는 Na-Cl 유형의 C-3 관정을 제외하고는 크게 두 그룹으로 구분되어 졌다. 다변량통계분석의 결과에서도 수리지화학, 동위원소, 용존유기물 등의 특성에서 나타나는 것과 유사한 연구지역의 수질특성을 확인할 수 있었다. 연구지역은 차시기 동안 수질변화는 일부 관정을 제외하고는 유의할 만한 수준으로 관찰되지는 않았고, 지하수 사용에 따른 지하수위 회복도 빠르게 진행되고 있는 것으로 나타났다.

  • PDF

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF