• Title/Summary/Keyword: 집적 기술

Search Result 932, Processing Time 0.025 seconds

The Relics of Wae Lineage and the Keyhole-Shaped Mounds in the Honam Area (호남지역(湖南地域)의 왜계자료(倭系資料)와 전방후원형고분(前方後圓形古墳))

  • Tsuchida, Junko
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.2
    • /
    • pp.170-203
    • /
    • 2018
  • From the period of Japanese colonialism up to the present, the researchers of archaeology and ancient history in Korea and Japan have paid much attention to the Honam area. Recently the ruins and relics of Wae lineage are often discovered at archaeological excavation sites in this region. In particular, at least 17 keyhole-shaped mounds were confirmed. The fact that three mounds were built on one site was newly revealed. Haniwa, a representative earthenware object of the Kofun period in Japan, was discovered as well. Therefore, the study of a historical meaning of archaeological materials about Wae lineage in the Honam area thus far must be reexamined. The ruins and relics of Wae lineage in the Honam area have been studied by selecting only specific cases. I identified all the ruins and relics of Wae lineage in the Honam area and analyzed the process of their change in this paper. I reviewed the relationship between Wae and Mahan, and the purpose of their negotiation based on archaeological characteristics, changing processes, and historical records on a quarterly basis. The ruins and relics of Wae lineage have increased and widely spread since the early period of the 5th century in the Honam area. This tendency continued until the late period of the 6th century. Weapons of Wae lineage were introduced and tombs in the style of Wae were built from the late 4th century to the early period of the 5th century (TG232~TK216 period). Sueki was introduced from the middle to late period of the 5th century (TK208~TK23 period). Keyhole-shaped mounds and tombs in the style of Wae were built from the late period of the 5th century to the early period of the 6th century (TK47~MT15 period). Japanese weapons were introduced from the middle to late period of the 6th century (TK10~TK209 period). In other words, the archaeological appearance is different in each quarterly period. There was an intensive diplomatic relationship between Baekje and Wae in the TG232~TK216 period. The military might be included in a mission of Wae. The materials of Wae lineage of this period are likely to be related to this. Sueki spread to the inland part of the Honam area in the TK208~TK23 period. This Sueki tends to be excavated on advantageous sites for the accumulation and distribution of supplies. The main characters of the keyhole-shaped mounds are presumed to be a group of traders which were under the control of a certain influence in the north of Kyushu. The keyhole-shaped mounds were abruptly built at some distance from mounds of the leaders in the Honam area. Additionally, there was no special influence base to which the characters of the keyhole-shaped mounds belonged in the surroundings. However, it might have been impossible for the group of traders to build the keyhole-shaped mounds without the support from the residents at all because there was a big difference in the building technology of the keyhole-shaped mounds between Japan and the Honam area. The time of building some keyhole-shaped mounds is the same or almost the same with that of the mounds built for the regional leaders. This proves a close relationship with the residents as well. What do the archaeological materials of Wae lineage which have been used and buried mean over 200 years in the Honam area? Geumgwan Gaya, which had exported iron resources to Japan, perished in the early period of the 5th century. Instead of Gaya, the Honam area might have played an important role to supply the necessary resources to Japan. We assume that the Japanese (Wae) actively worked to acquire various resources focusing on the underground resources in the Honam area.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF