• Title/Summary/Keyword: 집열에너지

Search Result 197, Processing Time 0.021 seconds

The Performance Assessment Study of Solar Energy Cogeneration panel for Building Integrated System (건물통합을 위한 태양에너지 cogeneration panel 특성 분석 연구)

  • Kim, Yong-Hwan;Kang, Eun-Chul;Hyun, Myung-Taek;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.35-42
    • /
    • 2006
  • Solar Thermal-Electric Integrated system can be used to generate heat and electricity simultaneously and can improve indoor all qualify. So, it can save heating and electricity cost as it operates at relatively lower temperatures. In this study, one pv module was fixed on a normal wall and a pv module was mounted on a solarwall. And a ventilation fan in the solar energy cogeneration panel was operated from 12:00 to 17:00 hours. Experimental results are recorded and anaysized. The comparison of results show that the temperature of PV on solar energy cogeneration panel was decreased by $7{\sim}9^{\circ}C$ and the electrical output was improved by $2{\sim}3W$ compared with a PV system without solarwall.

Heat efficiency Analysis of PVT module system using CFD (CFD를 이용한 PVT 모듈 열교환기 성능 해석)

  • Kim, Yangjoon;Kim, Dongkwon;Nam, Seungbaek;Cho, Insoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.112.2-112.2
    • /
    • 2011
  • PVT(Photovoltaic Thermal) 모듈은 태양광과 태양열 에너지를 동시 이용이 가능한 모듈로서 태양광전지(PV, Photovoltaic)모듈에 열교환기를 접합한 형태로 전기에너지뿐만 아니라 열에너지를 동시에 생산할 수 있는 시스템이다. 기존 PV 모듈은 일사량이 많으면 전력 생산량이 증가하는 동시에 PV모듈의 온도가 상승함에 따라 발전 효율이 감소하는 문제점이 있으며 일반적으로 $25^{\circ}C$이상 조건에서 모듈 온도가 $10^{\circ}C$ 증가할수록 발전효율의 약 4~5% 정도 감소하는 것으로 보고되고 있다. PVT 모듈은 기존 태양광모듈에 열교환기를 접합하여 냉각함으로써 PV모듈의 온도를 낮추어 발전효율을 증가시키는 동시에 부가적으로 발생하는 온수를 직접이용하거나 다양한 계통의 보조 열원으로 이용할 수 있는 장점이 있다. 본 연구에서는 수치해석기법(CFD)을 활용하여 PV모듈 냉각 및 온수 발생을 위한 열교환기를 설계하였으며 다양한 형상의 열교환기에 대해 유동해석을 수행하여 최적의 열흡수효율을 갖는 열교환기의 형상을 설계하였다. 또한 최적 설계된 PVT 모듈을 제작하여 실제 태양과 유사한 광원을 갖는 인공태양조건에서의 실내 실험을 통해 PVT 모듈의 성능을 검증하였으며 또한 실제 노상에 설치하여 ASHRAE 93-77의 실험기준과 ECN의 PVT 집열기 성능측정 가이드라인에 따라 옥외 시험평가를 하여 PVT 모듈의 성능 검증을 하였다. 최적 설계된 PVT모듈에 대한 성능평가 결과 기존 PV 모듈보다 발전효율이 약 15%(기존 발전효율 대비) 향상된 결과를 확인하였다.

  • PDF

A Study on the optimal Installation Angle of Solar Absorber Plates in Korea (국내 태양열 집열판의 최적 설치각 결정에 관한 연구)

  • Jo, Dok-Ki;Choi, In-Soo
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.69-89
    • /
    • 1998
  • The measured solar radiation incident on tilted surfaces by all directions has been widely used as important solar radiation data in installing solar collectors, hot water systems, and photovoltaic modules, and in designing solar buildings and houses. To maximize the incident beam radiation, the slope, which is the angle between the plane of the surface in question and the horizontal, and the solar azimuth angles are needed for these solar applied systems. To respond to above needs, a theoretical study with actual measurements on moving route of the sun is carried out. This study focuses on the development of an solar expert system and on the selection of slopes for solar absorber plates in Korea.

  • PDF

Status of High-Efficiency Solar Collector for Industrial Utilization (산업용 고효율 태양열집열기 개발 필요성)

  • Kwak, Hee-Youl
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.19-29
    • /
    • 1998
  • Solar energy is a quantitatively unlimited, clean and non-pollutant source. It has a great potential for industrial commercial usages. For example, solar hot water system for domestic usage has been very popular in many counties. In Korea, the industries consume 47.7% of the total national energy, and the manufacturing sector uses 91.5% out of it. The main energy resoures available in Korea are oils, coals, and gases. There have been continuous efforts among the industries to reduce such energy consumptions by using alternative energy resources, such as solar energy, yet the technology has limited its proper applications to a level of satisfaction. In some advanced countries, research and development programs in solar energy applicable to the industrial usages are very active, and some systems are in the commercial market. Therefore, this paper describes the status and the feasibility for high-efficiency evacuated solar collector which was anticipated to applied for industrial process heat as an alternative of fossil energy.

  • PDF

A Fundamental Study on Development of a Wall Structure type Thermal Diode for Energy Saving (에너지 절약을 위한 벽체형 열다이오드 개발에 관한 기초)

  • Pak, E.T.;Chang, Y.G.;Chea, S.S.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.67-73
    • /
    • 1997
  • In order to development of a new wall structure type thermal diode for energy saving, the numerical studies have been performed for natural convection across an rectangular enclosure with the various lengthes of the heat source and sink plate. The governing equations for the two-dimensional, laminar, natural convection process in an enclosure are discretized by the control volume approach which insures the conservative characteristics to be satisfied in the calculation domain, and solved by a elliptic SIMPLE algorithm. The momentum and energy equations are coupled through the buoyancy term.

  • PDF

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

A Development of Sun Tracking Control System for Parabolic Trough Concentrator (PTC용 태양 추적 장치의 개발)

  • Park, Y.C.;Kwak, H.Y.;Kang, Y.H.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.25-30
    • /
    • 1998
  • A sun tracking controller for PTC(parabolic trough concentrator) is a control system used to orient the concentrator toward the sun always, so that the maximum energy can be collected. The work presented here is a design and development of microprocessor based sun tracking control system for PTC. Sun tracking control system consists of a sun sensor and a single axis tracking control system. 80c196KC based control system consists of an analog input unit, 24V DC servomotor drive unit, I/O unit. Sun sensor has been constructed using photodiode and can detect the sun located within ${\pm}50^{\circ}$ measured from the sun sensor normal direction. The sun tracking system developed is being implemented and shows a good sun tracking performance.

  • PDF

Numerical approach for comparative performance study of tube type and box type hybrid photovoltaic/thermal system (시뮬레이션을 통한 박스형과 튜브형 태양광열 복합 시스템의 성능 분석)

  • Bhattarai, Sujala;Kim, Dae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.9-18
    • /
    • 2011
  • 태양광열 복합 시스템(photovoltaic/thermal hybrid solar system, PV/T)은 태양광 모듈 및 태양열 집열판의 단일화를 통한 전기 및 열에너지의 동시 생산이 가능하도록 구성되고 기존 태양광 모듈의 온도 상승에 따른 효율 저하의 문제점을 보완 및 발생하는 열을 회수하여 온수 생산이 가능한 장치이다. 본 연구에서는 액체형 PV/T 시스템의 대표적인 두 형태인 박스형과 튜브형의 성능 검증을 위하여 수학적 모델링을 통한 두 시스템의 열 및 전기적 성능을 비교 분석하였다. 모델링은 에너지 평형식을 이용하여 시간에 따른 각 부분의 온도의 변화를 예측할 수 있도록 수립되었으며 계산된 결과를 기준으로 전기, 열, 및 전체효율을 도출해 내고, 이를 바탕으로 두 시스템의 성능을 분석하였다. 시뮬레이션 결과를 바탕으로, 박스형 PV/T 시스템의 최고 온수 온도는 $52^{\circ}C$로 예측되었고, 반면에 튜브형은 $48^{\circ}C$에 머물렀다. 또한 열효율은 박스형이 최대 51%, 튜브형이 41%, 전기효율은 박스형이 약 14%, 그리고 튜브형이 13%로 나타났으며, 전체효율은 박스형이 73%, 그리고 튜브형이 64%로 나타나 박스형 PV/T 시스템이 튜브형보다 더 나은 성능을 가지는 것으로 예측되었다. 이는 박스형이 튜브형보다 태양광 모듈과 온수와의 접촉면적이 넓어 더 많은 열전달이 발생하기 때문으로 사료된다.

The Performance Simulation of All-Glass Vacuum Tubes with Coaxial Fluid Conduit (등축 유로를 가진 이중진공관형 태양열 집열기의 열성능에 관한 시뮬레이션 연구)

  • Lee, Sang-Jin;Hyun, Myung-Taek;Park, Youn-Cheol;Chun, Won-Gee;Lee, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.27-38
    • /
    • 2004
  • A numerical investigation has been carried out for a solar system, which consists of all glass solar vacuum tubes Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing all-glass solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show good agreement when compared with other experimental data demonstrating the reliability of the present model.

Development of a Renewable Energy Facility Design and Its Simulation Case Study (신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구)

  • Shin, Younggy;Kim, Eun Joo;Kim, Tae Hyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.464-470
    • /
    • 2013
  • Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.