DOI QR코드

DOI QR Code

Development of a Renewable Energy Facility Design and Its Simulation Case Study

신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구

  • Received : 2013.03.28
  • Published : 2013.08.10

Abstract

Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.

Keywords

References

  1. Renewable Energy Center, 2011, Introduction to the regulation of obligatory installation of renewable energy facilities, Download site of http://www.energy.or.kr, pp. 7-8.
  2. Byeon, W. S., Hwang, D. K., and Han, S. K., 2013, Certification Case of Building Energy Efficiency Grade of Wanjoo-gun Office Building and Administration Town, Magazine of the SAREK, Vol. 42, No. 2, pp. 28-37.
  3. Park, C. Y., 2011, Analysis of methods to estimate renewable energy production applied to building, Construction Technology Ssangyong, Summer 2011, pp. 17-23.
  4. KEMCO, 2008, Technology Information Net Q&A, http://kemco.or.kr/iecenter/net.
  5. Park, K. J., 2012, How Much Did REC Market Get Mature?, The Korea Electric Power Times, Oct. 29th.
  6. U.S. Department of Energy, 2010, Energy Plus The Most Powerful Predictor of a Building's Energy Efficiency, www.EnergyPlus.gov.
  7. Kim, M. K., 2012, Energy Consumption Estimation Model of Buildings in Seoul, Seoul Institute, Working Paper 2012-PR-33.
  8. ZEDfabric Company Ltd, 2013, ZED Products Catalog, heatweb.com/literature/ZedFactory%20All.pdf.
  9. Kong, H. J., Kang, S. J., Yun, K. S., and Lim, H. J., 2013, An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 3, pp. 156-163. https://doi.org/10.6110/KJACR.2013.25.3.156
  10. Martin, M. A., Durfee, D. J., and Hughes, P. J., 1999, Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools : Repair, Service, and Corrective Actions, Oak Ridge National Laboratory, 1999 ASHRAE Annual Meeting.
  11. Geothermal Technologies Office of DOE, 2013, Geothermal FAQs, http://www1.eere.energy.gov/geothermal/faqs.html.
  12. EPRI(Electric Power Research Institute), 2010, Addressing Solar Photovoltaic Operations and Maintenance Challenges, www.epri.com.
  13. NREL, 2012, Distributed Generation Renewable Energy Estimate of Costs, www.nrel.gov.
  14. Mathworks, 2012, Matlab Help Manual, Matlab 2012a.