• Title/Summary/Keyword: 집속초음파

Search Result 99, Processing Time 0.021 seconds

A Study on the Design and Fabrication of Fat Emulsification Adapted Focused Ultrasonic Transducer (지방 조직 유화를 위한 집속형 초음파 변환기 설계 및 제작에 관한 연구)

  • Kim, Ju-Young;Kim, Jae-Young;Jung, Hyun-Du;Noh, Si-Cheol;Mun, Chang-Su;Mun, Chi-Woong;Choi, Heung-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.127-134
    • /
    • 2015
  • Tissue stimulation technique using ultrasound has been continuously studied and developed. Recently, as a increment of interests for obesity treatment and cosmetic care, a various studies on ultrasonic fat emulsification has been conducted. In this study, the fat emulsification adapted ultrasonic transducer was designed. And using designed transducer, the simulation for the shape of focal area and thermal degradation region was conducted. The dimensions were verified by the simulation results. And the effectiveness was confirmed by evaluating measured radiation characteristic and heating characteristic. In addition, we estimated the ultrasonic heating characteristics in composite structure medium. The shape of focal point and heating characteristic of the proposed transducer were determined to be sufficient to emulsify the fat. The results of this study are considered to be used as basic research in more efficient and safe ultrasonic fat removal.

Fabrication of PVDF Line Focus Ultrasonic Transducer and its Application II. Applicatin to LSAW Measurement (직선집속 PVDF 초음파트랜스듀서의 제작과 응용 II. 누설탄성표면파 측정에의 응용)

  • Yoon Hyuck-joon;Ha Kang-lyeol;Kim Moo-joon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.391-394
    • /
    • 1999
  • 제작되어진 LFB PVDF 초음파트랜스듀서를 이용하여 누설탄성표면파(Leaky Surface Acoustic Wave : LSAW)측정을 하였다. 시료로서는 $SiO_2$, Al, Cu등을 사용하였고, 측정방법으로써는 초점면에 위치한 시료를 트랜스듀서 쪽으로 접근시켰을 때 LSAW가 트랜스듀서의 중심축을 통과한 후 시료표면에서 반사되어오는 종파와 분리되어지는 현상을 이용하였다. 실험결과는 Campbell and Jones의 이론에 의한 해석결과와 비교 분석하였는데 매우 잘 일치됨을 알 수 있었다.

  • PDF

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.391-401
    • /
    • 2004
  • 3D imaging systems using 2D phased arrays have a large number of active channels, compelling to use a very expensive and bulky beamforming hardware, and suffer from low volume rate because, in principle, at least one ultrasound transmit-receive event is necessary to construct each scanline. A high speed 3D imaging method using a cross array proposed previously to solve the above limitations can implement fast scanning and dynamic focusing in the lateral direction but suffer from low resolution except at the fixed transmit focusing along the elevational direction. To overcome these limitations, we propose a new real-time volumetric imaging method using a cross array based on the synthetic aperture technique. In the proposed method, ultrasound wave is transmitted successively using each elements of an 1D transmit array transducer, one at a time, which is placed along the elevational direction and for each firing, the returning pulse echoes are received using all elements of an 1D receive array transducer placed along the lateral direction. On receive, by employing the conventional dynamic focusing and synthetic aperture method along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. In addition, in the proposed method, a volume of interest consisting of any required number of slice images, can be constructed with the same number of transmit-receive steps as the total number of transmit array elements. Computer simulation results show that the proposed method can provide the same and greatly improved resolutions in the lateral and elevational directions, respectively, compared with the 3D imaging method using a cross array based on the conventional fixed focusing. In the accompanying paper, we will also propose a new real-time 3D imaging method using a cross array for improving transmit power and elevational spatial resolution, which uses linear wave fronts on transmit.

A Small Crack Length Evaluation Technique by Electronic Scanning (전자적 스캔에 의한 미소결함길이 평가기법)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detect-ability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination.

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

Cavitation suppression through the modification of spectral characteristics in the field of high intensity focused ultrasound (주파수 특성 변환을 통한 고강도 집속형 초음파 공동 현상의 억제)

  • 최민주
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.449-454
    • /
    • 1998
  • 전립선 비대증 및 각종 고형암 조직을 제거하기 위해 이용되는 고강도 집속형 초음파 시스템은 초음파의 조직에 대한 열 효과를 이용한다. 이 경우 수MPa의 고 압력 초음파를 사용하기 때문에 수술시 초음파에 의한 조직내의 공동 현상이 수반되고 이로 인해 초음파의 집속 효과가 감소하게 된다. 본 논문에서는 초음파 공동 현상을 억제하기 위하여 초음파의 주파수 특성을 고려하였다. 초음파의 크기는 일정하게 유지하면서 증가하는 주파수로 변조된 초음파와 비선형 고저파 (nonlinear harmonics) 성분을 포함한 왜곡된 초음파에 대한 기포의 반응을 Gilmore 기포 모델을 이용하여 관찰하였다. 초음파의 주파수 변조는 10 $\mu\textrm{s}$ 동안 초기 주파수 1 MHz부터 시작하여 7 MHz까지 선형적으로 증가하도록 하였다. 파형을 왜곡시키는 고저파 성분의 크기는 주파수에 역 비례 하도록 하였다. 초음파의 기본 주파수는 1 MHz로 하였고, 압력은 0.1 MPa과 1 MPa의 두 경우를 고려하였다. 초기 기포의 반경은 1 $\mu\textrm{m}$으로 하였고, 기포 주위의 유체는 물로 가정하였다. 시뮬레이션 결과로부터, 주파수를 변조시키거나 파형을 왜곡시킨 초음파에 대한 기포의 진동은, 동일한 압력의 정현파에 대한 경우 보다 작은 것으로 나타났다. 주파수 변조된 초음파에 반응한 기포의 진동은 압력이 낮을 때 (0.1 MPa), 변조된 주파수가 기포의 공진 주파수인 3 MHz 부근에서 최대치를 보이다가 이후 급격히 감소하는 경향을 보였다. 반면, 압력이 높아지면 (1 MPa) 기포의 진동은 주파수의 증가와 함께 감소하다가 3 MHz 이상으로 변조 될 경우, 유의한 변화를 보이지 않는 것으로 나타났다. 이 결과는 초음파의 적절한 주파수 성분 조절로 초음파 공동 현상을 일정 수준 억제할 수 있음을 시사한다. 고려가 수반되어야 할 것으로 보인다. 다음 내용을 정리해 보고자 한다.리해 보고자 한다.rc$ 구입할 때 중점적으로 살펴보는 사항은 신선도와 순수재래종 여부, 위생상태였다. 한편 소비자가 언제나 구입할 수 없다는 의견이 85.2%나 되어 원활한 공급과 시장조성이 아직 정착되지 않고 있었다. $\bigcirc$ 현재 유통되고 있는 재래종닭은 소비자 대부분이 잡종으로 인식하고 있었으며, 재래종과 일반육계와의 구별은 깃털색, 피부색, 정강이색등 외관상으로 구별하고 있었다. 체중에 대한 반응은 너무 작다는 의견이었고, 식품으로의 인식도는 비교적 고급식품으로 인식하고 있다. $\bigcirc$ 재래종닭고기의 브랜드화에 대한 견해는 젊고 소득이 높은 계층에서 브랜드화의 필요성을 강조하고 있다. $\bigcirc$ 재래종달걀의 소비형태는 대부분의 소비자가 좋아하였으나 아직 먹어보지 못한 응답자가 많았다. 재래종달걀의 맛에 대해서는 고소하고 독특하여 차별성을 느끼고 있었다. $\bigcirc$ 재래종달걀의 구입장소는 계란판매점(축협.농협), 슈퍼, 백화점, 재래닭 사육 농장등 다양하였으며 포장단위는 10개를 가장 선호하였고, 포장재료는 종이, 플라스틱, 짚의 순으로 좋아하였다. $\bigcirc$ 달걀의 가격은 200원정도를 적정하다고 하였으며, 크기는 (평균 52g)는 가장 적당하다고 인식하고 있으며, 난각색은 대부분의 응답자가 갈색을 선호하였다. $\bigcirc$ 재래종달걀의 구입시 애로사항은 믿을수 없고, 구입장소를 몰라서, 값이 싸다 등이었고, 앞으로 신뢰할 수 있고 위생적인 생산 및 유통체계가 확립될 경우 더 많이 소비하겠다는 의견이었다. $\bigcirc$ 재래닭 판매업소(식당)의 판매형태는 66.7%인 대부분

  • PDF

Tissue Mimicking Phantom for Visualization of Temperature Elevation Caused by Ultrasound (초음파에 의한 온도상승 가시화용 생체 모의매질)

  • Jung, Ji-Hee;Kim, Jung-Soon;Ha, Kang-Lyeol;Kim, Moo-Joon;Cao, Yonggang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.291-299
    • /
    • 2014
  • To probe the temperature elevation effect caused by ultrasound, a tissue mimicking phantom was newly suggested. A carrageenan gel was adopted to realize not only the required transparency for visualization but also acoustic characteristics similar to human tissue. To visualize the temperature elevation inside phantom, thermochromic film with a critical temperature of discoloration was introduced. Acoustic characteristics of the tissue mimicking phantom were examined when the concentrations of carrageenan and sucrose changed. As the results, the attenuation coefficient of the phantom could be controlled in the range of 0.44~0.49 dB/cm/MHz, and the acoustic impedance in the range of 1.52~1.77 Mrayls. We could control the acoustic characteristics of the phantom by different concentration of carrageenan and sucrose, and it was possible to examine the temperature elevation caused by ultrasound in the phantom. The suggested method was verified by noninvasively visualizing the temperature elevation due to planar and focused ultrasound using the fabricated phantom.

A Feasibility Study on the Application of Ultrasonic Method for Surface Crack Detection of SiC/SiC Composite Ceramics (SiC/SiC 복합재료 세라믹스 표면균열 탐지를 위한 초음파법 적용에 관한 기초연구)

  • Nam, Ki-Woo;Lee, Kun-Chan;Kohyama, Akira
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.479-484
    • /
    • 2009
  • Nondestructive evaluation(NDE) of ceramic matrix composites is essential for developing reliable ceramics for industrial applications. In the work, C-Scan image analysis has been used to characterize surface crack of SiC ceramics nondestructively. The possibility of detection of surface crack were carried out experimentally by two types of ultrasonic equipment of SDS-win and $\mu$-SDS, and three types of transducer of 25, 50 and 125 MHz. A surface micro-crack of ceramics was not detected by transducer of 25 MHz and 50 MHz. Though the focus method was detected dimly the crack by transducer of 125 MHz, the defocus method could detect the shape of diamond indenter. As a whole, the focus method and the defocus method came to the conclusion that micro crack have a good possibility for detection.

Development of Human-Head-Mimicking Phantom for Brain Treatment Using Focused Ultrasound (집속 초음파 뇌 질환 치료를 위한 두부 유사 팬텀의 개발)

  • Min, Jeonghwa;Kim, Juyoung;Noh, Sicheol;Choi, Heungho
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.433-439
    • /
    • 2013
  • In this study, human head-mimicking phantom was developed for brain disease treatment study using focused ultrasound. Acoustic parameters of skin, skull and brain were investigated through literature investigation and adequate substitutes according to each tissue were suggested. In the case of skin phantom, construction ratio of glycerol-based TMM phantom was controlled to mimic real skin. The suitability of skull substitutes was evaluated through measurement of acoustic parameters. In the case of brain phantom, transparent egg white phantom was used to observe thermal properties of focused ultrasound. Combined human-head-mimicking phantom using each substitutes was fabricated for development of brain disease treatment protocol. Denaturation of brain phantom according to ultrasonic condition was observed for validation.