• Title/Summary/Keyword: 질량

Search Result 4,610, Processing Time 0.031 seconds

Time-dependent Evolution of Accretion Disk Mass in a Black Hole Microquasar Candidate A0620-00 (블랙홀 마이크로퀘이사 후보 A0620-00의 강착원반 질량의 시간적 진화)

  • Kim, Soon-Wook
    • Journal of the Korean earth science society
    • /
    • v.29 no.7
    • /
    • pp.579-585
    • /
    • 2008
  • The time-dependent evolution of disk mass for outburst limit cycle in a black hole microquasar is calculated based on the non-linear hydrodynamic model of thermally unstable accretion disk. The physical parameters such as black hole mass, disk size and mass transfer rate are adopted to reproduce the historical 1975 outburst observed in a prototype black hole X-ray nova A0620-00. The time-dependent effect of irradiation from the central hot region to the disk is considered in two ways: direct irradiation and indirect irradiation reflected from hot accretion flow above the disk. The accretion disk thermal instability model can account for the bolometric luminosity appropriate to typical characteristics of system luminosity observed in X-ray transients during the whole cycle of the outburst evolution. The maximum mass of the accretion disk, ${\sim}4.03{\times}10^{24}g$, is achieved at the ignition of an outburst, and the minimum value, ${\sim}8.54{\times}10^{23}g$, is reached during the cooling decay to quiescence. The disk mass varies ${\sim}5$ times during outburst limit cycle.

Optimal Nozzle Design of Bladeless Fan Using Design of Experiments (실험계획법을 이용한 날개 없는 선풍기의 노즐 형상 최적 설계)

  • Jeong, Siyoung;Lee, Jongsoo;Yoon, Jaehyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.711-719
    • /
    • 2017
  • Bladeless fan is becoming increasingly popular owing to its advantages, such as improved safety, easy to clean, and attractive shape. However, many people are reluctant to purchase it because of several disadvantages, such as noise and moderate wind; therefore, research on how improve wind generation without increasing the motor speed is required. This study investigates the optimization of the shape of the nozzle and nearby surface using CFD (Computational Fluid Dynamics) simulation, ANSYS fluent. The results are analyzed by ANOM (analysis of mean) and interaction analysis; therefore this study suggests the variables of affecting Coanda effect and satisfy the govern equation, the conservation of momentum. The optimal combination was found through a predictive equation. In this study, factors and levels that affect the mass flow rate were selected and experimental points were arranged using the orthogonal array table. The value of the mass flow rate was confirmed by ANSYS fluent, which is a CFD program. Through the ANOM, it was confirmed that the nozzle distance is the most influential parameter affecting the mass flow rate. Furthermore, the mass flow rate obtained from the predictive equation and the mass flow rate from the CFD correspond to the largest values. Results from this study confirmed that the mass flow rate is increased by a change in the shape, even if the motor speed did not increase.

Application of MALDI-TOF mass spectrometry-based identification of foodborne pathogen tests to the Korea Food Standard Codex (MALDI-TOF 질량분석기를 이용한 식품중독균 확인시험 적용)

  • Ha, Miyoung;Son, Eun Jung;Choi, Eun Jeong
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.437-444
    • /
    • 2016
  • Rapid and reliable identification of microorganisms is important to maintain food quality and to control safety. MALDI-TOF MS-based identification methods are relatively fast and simple compared to other conventional methods including gram staining and biochemical characterization. A colony on subcultured media can be directly prepared on the analysis plate without further complex treatments. In this study, we confirmed the applicability of MALDI-TOF MS-based identification of foodborne pathogens such as Salmonella Enteritidis/Typhimurium, Staphylococcus aureus, Vibrio parahaemolyticus, Clostridium perfringens, Listeria monocytogenes, Yersinia enterocolitica, Bacillus cereus, Campylobacter jejuni, Campylobacter coli, and Cronobacter sakazakii on the Korea Food Standard Codex. MALDI-TOF MS data of the pathogenic reference strains were incorporated into a commercial MicroID (ASTA Inc.) database. Other pathogenic reference strains and seven isolates from various food samples were correctly identified to the species level by using the MicroID database. In conclusion, MALDI-TOF MS is comparable with commercial biochemical identification.

우주환경하에서의 진동자의 주파수 변화 측정에 의한 질량 측정 시스템 및 방법

  • Kim, Youn-Kyu;Kim, Jong-Woo;Kim, Kwong-Sik;Choi, Gi-Hyuk
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.216-219
    • /
    • 2005
  • In this study, we will explain the design, test results and analysis of system for measuring the small mass in the microgravity environment. It is so difficult to measure the mass by sensing the gravity as the ground in the microgravity environment. The suggested method is to measure the resonance frequency of a sample. The resonance frequency may be measured as a function of mass. If we know the resonance frequency of the mass, we can guess the mass by detecting the resonance frequency. Piezoelectric ceramics have the characteristics that resonance frequency is changed by total mass which are its mass and the attached mass. This system have some problems but we verified that we can measure the unknown mass using the resonance frequency as the mass.

  • PDF

Effects of Imperfect Fixing at the Active End of Spring-top Resonant Column Apparatus (주동단에 반력으프링이 부착된 공진우 시험기에서 우동단 불완전 고정의 영향)

  • 민덕기
    • Geotechnical Engineering
    • /
    • v.6 no.1
    • /
    • pp.7-14
    • /
    • 1990
  • The two degree of freedom model is proposed to study the effects of imperfect fixing at the active end of spring-top resonant column apparatus. A computer program using the SYMPHONY spreadsheet is developed to calculate the dimensionless frequency, F, from which modulug can be determined. It is found that the effect of reaction mass through the parameter Tr on dimensionless frequency, F, can not be ignored if Tr$\leq$20. As To increases, the variation of F increases. But for Tr$\geq$ 20, the effect of To becomes small. It is recommended that T. be greater than 20 if single degree of freedom model is rosed to determine modulus of soil. It also is found that damping ratios of specimen and apparatus do not strongly affect the dimensionless frequency, F.

  • PDF

Experimental Study on the Static Balancing Method of an Unbalanced Rigid Rotor (불평형 회전체의 정적평형 방법에 대한 실험적 연구)

  • Chang, Ho-Gyeong;Kim, Sung-Kyu;Kim, Ye-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.13-22
    • /
    • 1991
  • The presence of an unbalanced mass is originated the common source of vibration in machines with rotating rotor. In this study, the unbalanced rigid rotor mounted on an overhang shaft is balanced using the static balancing procedure, and the compensation mass is estimated by the phase angle method and four run method. Also, the reduction of vibration level before and after balancing is examined. In the experimental results, it is shown that the vibration due to the unbalanced mass is decreased by eliminating the effect of the unbalance. Above all, the four run method is proved more effective on the ability of vibration reduction, in small unbalanced mass, the phase angle method.

  • PDF

Numerical Study on the Performance of the Round Type Impactor (원형 임팩터의 성능에 관한 수치적 연구)

  • 허재영;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.292-298
    • /
    • 1991
  • Previous studies on the performance of the round type impactor were reexamined and extended to the case of high particle mass loading. It was pointed out that the previous numerical studies need to be supplemented in the numerical process. The impactor performance was calculated under the same conditions as previous studies by the exact calculation process and it was found out that a tail of the collection efficiency curve, which have not been found in the previous studies, appeared in the results of ours. Numerical results for high particle mass loading show that the value of the collection efficiency in the impactor decreases but better particle-cut characteristics can be obtained, as the amount of the particle mass loading increases.

BIACORE 바이오센서를 이용한 B형 간염 표면항원 정량분석의 기초연구

  • Yu, Chang-Hun;Ryu, Gang;Jeon, Jun-Yeong;Lee, Hyeon-Ik;Choe, Seong-Cheol;Lee, Eun-Gyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.231-234
    • /
    • 2001
  • We performed a basic experiment for rapid. on-line, real-time measurement of HBsAg by using a BIACORE biosensor, a chip-based sensor utilizing surface plasmon resonance technology to quantify the recognition and interaction of biomolecules. We immobilized an a -HBsAg antibody on a CM5 chip surface which was activated by N-hydroxysuccinimide for amine coupling with HBsAg, and measured the mass increase from the coupling. This study showed the potential of this biosensor-based method as a rapid, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification.

  • PDF

Critical Loads of Tapered Cantilever Columns with a Tip Mass (자유단 집중질량을 갖는 변단면 캔틸레버 기둥의 임계하중)

  • Jeong, Jin Seob;Lee, Byoung Koo;Kim, Gwon Sik;Kim, Jong Ung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.699-705
    • /
    • 2005
  • This paper investigates critical loads of tapered cantilever columns with a tip mass, subjected to a follower force. The linearly tapered solid rectangular cross-sections are adopted as the column taper. The differential equation governing free vibrations of such columns, also called Beck's columns, is derived using the Bernoulli-Euler beam theory. Both divergence and flutter critical loads are calculated from the load-frequency curves that are obtained by solving the differential equation. The critical loads are presented as functions of various non-dimensional system parameters, namely, the taper type, the subtangential parameter, and the mass ratio.

Ion Exchange Modeling with Mass Action Law and Surface Complexation Models (질량작용법칙과 표면착화모델을 이용한 이온교환 모델링)

  • 안현경;김상대;이인형
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.296-300
    • /
    • 2003
  • A large equilibrium and kinetic data set for multi-component cation exchanges was obtained and tested with mass action law and surface complexation model. The systematic batch equilibrium and column experiments of cation adsorption were conducted for binary, ternary, quaternary, and quinary cation exchanges involving $ H^{+}, Li^ {+}, Na^{+}, NH$_4$^{+}, Mg^{2+} $ on a strongly acidic cation exchange resin IRN 77. The mass action law and surface complexation model were tested against both data set to investigate the consistency of ion selectivity and their predictability for competitive cation exchanges. Surface complexation model provided more accurate predictions for both equilibrium and kinetic experimental data than mass action model.

  • PDF