Effects of Imperfect Fixing at the Active End of Spring-top Resonant Column Apparatus

주동단에 반력으프링이 부착된 공진우 시험기에서 우동단 불완전 고정의 영향

  • 민덕기 (정회원, 울산대학교 공과대학 토목공학과)
  • Published : 1990.03.01

Abstract

The two degree of freedom model is proposed to study the effects of imperfect fixing at the active end of spring-top resonant column apparatus. A computer program using the SYMPHONY spreadsheet is developed to calculate the dimensionless frequency, F, from which modulug can be determined. It is found that the effect of reaction mass through the parameter Tr on dimensionless frequency, F, can not be ignored if Tr$\leq$20. As To increases, the variation of F increases. But for Tr$\geq$ 20, the effect of To becomes small. It is recommended that T. be greater than 20 if single degree of freedom model is rosed to determine modulus of soil. It also is found that damping ratios of specimen and apparatus do not strongly affect the dimensionless frequency, F.

주동단에 반력스프링이 부착된 공진주(spring-top resonant column) 시험기 주동단 불완전 고정의 영향을 연구하기 위해 2자유도 모델을 제안하였다. SYMPHONY스프레드쉿트를 이용하여 무차원주파수, F를 구할 수 있도록 전산화하였으며 이로부터 탄성계수를 구할 수 있다. F에 대한 반력 질량의 영향은 반력질량 및 시료의 질량 및 주파수에 관계되는 계수, T<20인 경우에 는 무시할 수 없음을 밝혔다. 시험기 및 시료의 질량과 주파수에 관계되는 계수, Tci가 증가함에 따라 F의 영향 역시 증가하였으나 T도 20인 경우 그 영향은 적었다. 주동단 고정을 위해서는 T, 이 20이상 되어야 함을 제안하였으며 이 경우 SDOF으로 취급할 수 있다. 시료와 시험기의 감쇠비는 F에 크게 영향을 미치지 않음도 밝혔다.

Keywords