• Title/Summary/Keyword: 질량평균

Search Result 317, Processing Time 0.028 seconds

An Experimental Study on the Spray Characteristics of Internal Mixing Atomizer for Twin Fluid (내부혼합형 2유체 미립화기의 분무 특성에 관한 실험적 연구)

  • Kim, K.C.;Ha, M.H.;NamKung, J.H.;Lee, S.G.;Rho, B.J.;Kang, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.693-698
    • /
    • 2001
  • An experimental study was carried out with an aerated nozzle. This nozzle was well known that the performance of the atomization is better than other ones even though the supplied air pressure is lower than that of them. The purpose of this investigation is to provide the essential information of the aerated nozzle from the nozzle exit. The experimental work was performed in order to analyze the characteristics of the overall flow field from the nozzle exit. The 2-D PDPA system was used to acquire the data in the concerned region. The characteristics of the mean velocity distribution, half-width, and SMD were mainly analyzed. Also the correlation between turbulent kinetic energy and SMD was described with ALR.

  • PDF

A Study on the Performance of EFI Engine Used Ultrasonic Energy Adding Fuel system(II) -Attaching Importance to the Fuel Spray- (초음파연료공급창치를 이용한 EFI기관의 성능에 관한 연구(II) -연료 분사를 중심으로-)

  • 윤면근;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.80-86
    • /
    • 1997
  • This experiment was undertaken to investigate spray characteristics of the conventional injection system and the ultrasonic energy added injection system. Sauter mean diameter was measured under the variation of injection pressure and the spray distance. To measure the droplet size, we used the Malvern system 2600C. The spray angle and mass distribution were analyzed to the CCD camera and the patternater. After experiment, it was found that the ultrasonic energy added injection system had smaller Sauter mean diameter of droplet, wider mass distribution and wider spray angle than the conventional injection system had.

  • PDF

Hough Transform Using Direction Prediction (HTUDP) (방향예측을 이용한 하프변환)

  • Cho, Bo-Ho;Jung, Sung-Hwan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.366-368
    • /
    • 2012
  • 컴퓨터 비전 분야에서 직선은 사용자에게 기본적인 정보를 제공할 뿐만 아니라, 이를 바탕으로 다양한 분야에 응용할 수 있는 중요한 정보이다. 직선검출을 위한 여러 방법들 중에서 컴퓨터 비전 분야에 널리 사용되는 방법은 하프변환이다. 그러나 하프변환은 처리시간 비용이 높은 문제점을 가지고 있다. 본 논문에서는 이 문제를 개선하기 위한 방법으로 직선의 방향예측을 이용한 하프변환을 제안한다. 먼저, 영상의 각 화소의 기울기를 바탕으로 방향정보를 획득하고, 획득한 방향정보를 일정한 범위로 조정한다. 다음, 범위 조정된 방향정보의 확률질량함수를 구하고, 그것의 평균과 표준편차를 문턱치로 사용하여 영상에서 직선의 방향을 예측한다. 그리고 예측한 방향에 대하여 하프변환을 수행하여 영상에서 직선을 검출한다. 본 논문에서 제안한 방법은 기존의 방법들과 비교 평가에서 그 우수함을 보였다.

분사액체와 운용조건이 공기충돌형 인젝터에 의해 형성되는 액적의 분무특성에 미치는 영향

  • Park, Seung-Gyu;Han, Jae-Seob;Kim, Yoo;Kim, Sun-Jin;Park, Jung-Bae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.8-8
    • /
    • 1999
  • 2-유체 인젝터의 분무연소에 대한 통찰 및 구조에 대한 이해와 연료-공기 혼합과 연소반응의 물리적 이해에 필요한 수치적 모델의 개발 및 검증을 위해서는 2유체 시스템에서 액체 및 기체 각각의 기본적 특성인 액적크기, 액적속도, 액적의 질량플럭스(flux), 가스상의 속도측정 등이 필요하다. 특히, 액체분무에서는 액적의 크기를 예측하는 것이 매우 중요한 과제이며, 액적의 크기에 영향을 주는 인자들로는 노즐의 형태, 분사액체의 물성치(점도, 표면장력, 밀도), 주위기체의 조건(온도, 압력, 응축과 증발현상), 분사압력 등이 있다. 그러나, 실제 분무액적의 크기는 분포를 가지므로 같은 SMD를 가지더라도 그 분포의 정도는 크게 다를 수 있어 결과적으로 분무액적의 크기를 평균값만으로 표현하는 것은 불충분할 뿐만 아니라 그 적용에도 한계를 가지게 된다. 따라서 분무액적의 평균크기와 함께 그 분포의 정도 등을 함께 나타내려는 시도가 많은 과학자들에 의하여 연구되었다.

  • PDF

Effects of Perfusion Defect on the Measurement of Left Ventricular Mass, Ventricular Volume and Post-stress Left Ventricular Ejection Fraction in Gated Myocardial Perfusion SPECT (정량적 게이트 심근관류 스펙트 검사에서 관류결손이 좌심근질량 측정과 부하 후 좌심실 용적 및 구혈률에 미치는 영향)

  • Ahn, Byeong-Cheol;Bae, Sun-Keun;Lee, Sang-Woo;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.381-391
    • /
    • 2002
  • Purpose: The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluate the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Subjects and Methods: Forty-six patients (male/female=34:12, mean age=64years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by AutoQUANT program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. Results: LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS un patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between EDVs, ESVs, EFs than patients with reversible defect. Conclusion: These results suggest that perfusion defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

Long-term Variations of Troposphere-Stratosphere Mean Meridional Circulation (대류권-성층권 평균자오면순환의 장기변동)

  • Seol, Dong-Il
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.415-422
    • /
    • 2001
  • Studies of atmospheric general circulation in the troposphere and stratosphere are very important to understand the influence of human activities on the global climate and its change. Recently, the existence of an annual cycle in the circulation has been reported by a number of studies. In this study, the residual mean meridional circulation is calculated by the TEM momentum and continuity equations for the period from December 1985 to November 1995 (10 years), and the long-term variations of the circulation and mass fluxes across the 100hPa surface are examined. The multiple regression statistical model is used to obtain quantitatively the long-term variations. This study is focused especially on mean meridional circulation in the troposphere and stratosphere associated with ENSO (El Ni${\tilde{n}}$o-Southern Oscillation) which is known as a cause of the unusual weather, global climate, and its change. The results show that the global scale troposphere-stratosphere mean meridional circulation is intensified during El Ni${\tilde{n}}$o event and QBO (quasi-biennal oscillation) easterly phase and weakened during La Ni${\tilde{n}}$o event and QBO westerly phase. The signal of Mount Pinatubo volcanic eruption in June 1991 is obtained. Due to the volcanic eruption the global scale troposphere-stratosphere mean meridional circulation is abruptly intensified.

  • PDF

A Study on Loose Part Monitoring System in Nuclear Power Plant Based on Neural Network (원전 금속파편시스템에 신경회로망 적용연구)

  • Kim, Jung-Soo;Hwang, In-Koo;Kim, Jung-Tak;Moon, Byung-Soo;Lyou, Joon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.227-230
    • /
    • 2002
  • The Loose Part Monitoring System(LPMS) has been designed to detect, locate and evaluate detached or loosened parts and foreign objects in the reactor coolant system. In this paper, at first, we presents an application of the back propagation neural network. At the preprocessing step, the moving window average filter is adopted to reject the low frequency background noise components. And then, extracting the acoustic signature such as Starting point of impact signal, Rising time, Half period, and Global time, they are used as the inputs to neural network. Secondly, we applied the neural network algorithm to LPMS in order to estimate the mass of loose parts. We trained the impact test data of YGN3 using the backpropagation method. The input parameter for training is Rising Time, Half Period, Maximum amplitude. The result showed that the neural network would be applied to LPMS. Also, applying the neural network to the Practical false alarm data during startup and impact test signal at nuclear power Plant, the false alarms are reduced effectively. 1.

  • PDF

Effect of Flame Retardants on Flame Retardancy of Flexible Polyurethane Foam (난연제 종류에 따른 연질 폴리우레탄 폼의 난연 특성에 대한 연구)

  • Kwon, Ohdeok;Lee, Ju-Chan;Seo, Ki-Seog;Seo, Chung-Seok;Kim, Sang Bum
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 2013
  • In this study, the effect of phosphorus flame retardants on the flame retardancy of the flexible polyurethane foam (PUF) was investigated. Tetramethylene bis(orthophosphorylurea) [TBPU] and phosphinyl alkylphosphate ester [CR-530], resorcinol bis diphenylphosphate [RDP], triethyl phosphate [TEP] were used as flame retardants. The results of thermogravimetric analysis (TGA) indicate that TBPU added PUF produces more charred residues than the other flame retardant added PUF. It was found that TBPU added PUF exhibits low mean heat release rate (HRR), peak HRR, effective heat of combusion (EHC), mass loss rate (MLR), CO yield and $CO_2$ compared to those other flame retardants.

Effect of the lubrication oil on heat transfer and pressure drop characteristics of supercritical carbon dioxide in a microfin tube (마이크로핀관내 냉동기유가 초임계 이산화탄소의 열전달과 압력강하에 미치는 영향)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1440-1446
    • /
    • 2012
  • This paper presents an experimental study of heat transfer and pressure drop characteristics of supercritical carbon dioxide with PAG inside a horizontal microfin tube. Heat transfer coefficient and pressure drop gradients were measured at 10 MPa in pressure and 520 kg/$m^2s$ in mass flux with variation of PAG mass concentration from 0.06% to 2.26%. The tendencies of both heat transfer and frictional pressure drop characteristics show the same as those of pure $CO_2$ up to 0.3% in PAG mass concentration. In case of 2.26% in PAG mass concentration, measured heat transfer coefficients showed 50% lower than those of pure $CO_2$ near the pseudocritical temperature and measured frictional pressure drop gradients show 1.6 times higher in comparison with those of pure $CO_2$ at $60^{\circ}C$ in $CO_2$ bulk temperature.

Effects of Pressure-Side Winglet at an Elevation of Tip Surface on the Tip-Leakage Flow and Aerodynamic Loss Downstream of a Turbine Blade Equipped with Pressure-Side Squealer Tip (압력면익단소익이 터빈 동익 압력면스퀼러팁 하류의 팁누설유동 및 압력손실에 미치는 영향)

  • Cheon, Joo Hong;Lee, Sang Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.645-651
    • /
    • 2016
  • Effects of pressure-side winglet width on the tip leakage flow and aerodynamic loss downstream of a turbine blade with a pressure-side squealer rim have been investigated for the tip gap-to-span ratio of h/s = 1.36%. The pressure-side squealer has a fixed height-to-span ratio of $h_p/s=3.75%$ and the pressure-side winglet, which is installed at an elevation of tip surface, has width-to-pitch ratios of w/p = 2.64%, 5.28%, 7.92% and 10.55%. The results show that with increasing w/p, aerodynamic loss in the passage vortex region decreases, whereas that in the leakage flow region increases. As a result, the mass-averaged loss coefficient all over the measurement plane tends to decrease minutely with the increment of w/p. It is concluded that the pressure-side winglet for the pressure-side squealer tip can hardly contribute to the tip-leakge loss reduction.