Case study of microseismic techniques for stability analysis of pillars in a limestone mine (석회석 광산 내 광주의 안정성 분석을 위한 미소진동 계측기술의 현장적용)

  • Kim, Chang Oh;Um, Woo-Yong;Chung, So-Keul;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • This study deals with the case that was the field application of the microseismic monitoring techniques for the stability monitoring in a domestic mine. The usefulness and limitations of the microseismic techniques were examined through analyzing the microseismic monitored data. The target limestone mine adopted a hybrid room-and-pillar mining method to improve the extraction ratio. The accelerometers were installed in each vertical pillar within the test bed which has the horizontal cross-section $50m{\times}50m$. The measured signals were divided into 4 types; blasting induced signal, drilling induced signal, damage induced signal, and electric noise. The stability analysis was performed based on the measured damage induced signals. After the blasting in the mining section close to the test bed, the damage of the pillar was increased and rockfall near the test bed could be estimated from monitored microseismic data. It was possible to assess the pillar stability from the changes of daily monitored data and the proposed safety criteria from the accumulated monitored data. However, there was a difficulty to determine the 3D microseismic source positions due to the 2D local sensor arrays. Also, it was needed to use real-time monitoring methods in domestic mines. By complementing the problems encountered in the mine application and comparing microseismic monitored data with mining operations, the microseismic monitoring technique can be used as a better safety method.

A Comparison Analysis on The Vibration Test Standard and The Dynamic Characteristic Test of 9,000 Btu Military Airconditioner Applying Refrigerant R-410A (R-410A 냉매를 적용한 9,000Btu 군용에어컨의 진동시험규격과 동특성시험 비교 분석)

  • Choi, Dong-Seol;Lee, Won-Young;Shin, Young-Hun;Lim, Young-Taik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.519-520
    • /
    • 2010
  • R-410A 냉매를 적용한 9,000 Btu 군용에어컨은 2 1/2톤 쉘터카고 차량에 탑재된 쉘터를 냉, 난방하기 위해 사용된다. 이 에어컨은 차량에 탑재된 쉘터의 벽면에 설치되기 때문에 차량 이동 중의 진동, 충격 환경에서 그 기능이 유지되어야 하며, 이에 대한 진동시험을 실시한다. 진동시험은 MIL-STD-810G, 514.5C-VII Composite Wheeled Vehicle 규격에 따라 수행하며, 동특성시험을 통해 확보된 입력 진동값을 진동 규격과 비교하여 적합성을 판단한다.

  • PDF

특집 : IT 융복합의료기기 기술 - 가상현실과 연동된 전신 진동기의 운동효과 및 관련 동향

  • Jeong, Gyeong-Yeol;Im, Byeong-Ju;Park, Chang-Dae;Lee, Byeong-Gwon;Cheon, Seung-Cheol
    • 기계와재료
    • /
    • v.23 no.1
    • /
    • pp.24-32
    • /
    • 2011
  • 최근 다양한 연구를 통하여 전신 진동기 운동이 신체의 근골격계, 순환계 및 내분비계 등에 효과적임이 보고되고 있다. 특히 전신 진동운동이 노인의 낙상예방, 파킨슨 및 뇌졸중 환자와 같은 신경학적 질환자의 자세조절 및 기능향상을 위한 재활치료 방법으로 효과가 있다고 밝혀졌다. 그러나 아직까지 전신 진동운동에 적합한 의료 허가를 받은 제품이 없으며, 일부 유사한 진동감을 제공하는 기기를 위주로 제작되고 있는 상황이다. 추후 의료기기의 수요를 고려할 때 고령사회로의 진입 속도가 빨라짐에 따라 노인들에게 적합한 진동기의 개발이 필요하다. 노인들은 운동참여에 보수적이며 사회성이 떨어지기 때문에 운동기의 기능적 요건과 더불어 참여를 유도하는 환경 요인을 함께 제공할 필요가 있다. 본 논문에서는 진동 운동기를 이용한 운동 효과를 분석하고 전신 진동운동에 적합한 가상현실 컨텐츠를 제시하였으며, 국내외 개발 및 연구 중인 기기와 컨텐츠 개발 동향을 제시하였다.

  • PDF

A Study on Experimental Analysis and Prediction Method of Vibration of Egines due to Piston-Slap (피스톤 슬랩에 의한 엔진 진동 현상의 실험적 분석과 예측 방법에 관한 연구)

  • 김양한;권기웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.31-35
    • /
    • 1992
  • 자동차 관련 소음 및 진동중 엔진과 관련된 것은 흡.배기계 소음과 엔진 자 체의 각 구동 부위 및 연소실 소음으로 대별하여 볼수 있다. 특히 연소실 소 음의 경우에는 엔진 내부에서 발생하는 진동과 압력파가 엔진을 진동시키고, 이러한 엔진의 진동이 방사음을 발생시켜 형성되는 만큼 그 해석 및 공학적 접근 방법이 용이하지 않다. 연소실 소음은 압력의 갑작스런 변화에 의한 폭 발소음과 피스톤과 실린더 벽면의 충돌에 의한 피스톤 슬랩(piston slap)으로 크게 구분할 수 있으며 압력이 높지 않고 압력의 변화가 빠르지 않을 경우 에는 피스톤 슬랩이 기계적 소음의 주 원인이 되는 것으로 알려져 있다. 본 고에서는 피스톤 슬랩에 의한 진동 현상을 예측하기 위한 이론적 접근 방법 을 제시하고 이의 타당성을 검증하기 위한 실험적 방법을 제시하고자 한다. 또한, 피스톤과 실린더의 간극 진단을 위해 슬랩 신호를 이용하는 방법에 대 해 살펴보고, 피스톤과 실린더의 충돌 속도를 통해 슬랩 신호를 줄이기 위한 엔진의 설계 방법에 대해 살펴보고자 한다.

  • PDF

Natural Frequencies of Simply Supported Tapered Beams (단순지지된 변단면 보의 고유진동수)

  • 김준희;김순철;이수곤
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.607-612
    • /
    • 1999
  • Natural frequencies of non-symmetrically tapered beams with simply supported ends were determined by solving the frequency equations. In the case of symmetrically tapered beams. the finite element method was adopted for frequency computation. Computed frequencies of tapered beams were expressed as functions of taper ratio. a. and sectional properties. ( m, n).

  • PDF

experimental Investigation of Noise and Vibration Phenomena of a Heavy-duty Truck at High-Speed Driving (대형트럭의 고속 주행시 진동소음 현상에 관한 실험적 연구)

  • Lee, Yang-Sup;Han, Moon-Sik;Cho, Hang-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.77-82
    • /
    • 1999
  • 대형 화물트럭의 차실 내에 높은 수준의 차바닥 진동을 수반한 높은 소음이 발생하였다. 측정 및 분석결과 문제의 진동 소음은 추진축의 회전 1차 및 2차 성분으로 나타났다. 진동 전달경로상의 구성계 및 구성요소들에 대해 모드해석과 실차 주행 모드 해석시험을 실시한 결과 드라이브라인 및 프레임의 공진주파수가 문제가 되는 소음진동 주파수와 거의 일치하였으며, 또한 캡의 실내음향 공진 모드가 문제되는 주파수에서 존재하였다. 실험결과에 따라 액슬과 액슬간의 축의 장착각도를 변경하여 가진력을 줄이고, 비틀림 동흡진기를 추진축에 장착하여 드라이브라인계 공진을 제어함으로써 문제의 시내진동소음을 현저히 개선하였다.

  • PDF

A Study on Reducing Vibration of Oil-Free Reciprocating Air Compressors (오일프리 왕복동식 공기압축기 진동저감을 위한 방안 연구)

  • Song, Min-Su;Park, Eun-Suk;Hwang, Sung-Wook;Oh, Seok-Jin;Ko, Hyung-Keun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.656-662
    • /
    • 2011
  • Recently, rolling stock technology has rapidly developed. Nevertheless, ride quality and vibration vibration on vehicle still need more study. EMU to be operated on SMRT Line 7(SR001) extension section is applied to oil-free reciprocating air compressor considering maintainability and convenience of inspection. But reciprocating air compressor compresses the air by back-and-forth motion of piston, and spreads the vibration to surrounding structures by its force of inertia. Optimum design of mounting bracket is able to reduce the vibration. As a result, we analyzed the frequency spectrum on vibration upon value by measuring vibration during operation of air compressor. On this study, we comprehend the vibration transmission process of reciprocating air compressor and consider the measure for reducing vibration by minimizing propagation of vibration.

  • PDF

Estimation of Wind Resistance Capacity of Nielsen Arch Bridge Based on Measured Data From Monitoring System (모니터링 시스템의 계측자료를 기반으로 한 닐슨아치 교량의 내풍 안정성 평가)

  • Lee, Deok Keun;Yhim, Sung Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.56-64
    • /
    • 2013
  • The wind resistant capacity of bridges with a span of less than 200m is typically evaluated by Wind Resistant Design Manual for Highway Bridges in Japan. Also, the first vertical frequency plays an important role in the evaluation of their aerodynamic performance. An unexpected vortex-induced vibration of Nielsen arch bridge with span of 183m designed by this manual has been measured by monitoring system during typhoon. The amplitude of vibrations was about 2 times than the allowable vibration displacement. This paper presents the feature of vortex-induced vibration of this Nielsen arch bridge based on measured wind velocity, wind direction, and responses at midspan of main girder. From the result of FFT, the $1^{st}$ mode shape of the bridge is antisymmetric and the $2^{nd}$ is symmetric. Also, the dominant vibration of the bridge is the $2^{nd}$ vertical mode. According to these results, the $2^{nd}$ vertical vibration mode of this Nielsen arch bridge is prior to the first for the estimation of wind resistance capacity.

Vibration Identification of Gasoline Direct Injection Engine Based on Partial Coherence Function (부분기여도 함수를 이용한 직접분사 가솔린 엔진 부품의 진동원 분석)

  • Chang, Ji-Uk;Lee, Sang-Kwon;Park, Jong-Ho;Kim, Byung-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1371-1379
    • /
    • 2012
  • This paper presents a method for estimating the contribution of vibration sources in gasoline direct injection engine parts with a multiple-input system. A partial coherence function was used to identify the cause of the linear dependence indicated by an ordinary coherence function. To apply the partial coherence function to vibration source identification in the powertrain system of a gasoline direct injection engine, a virtual model of a two-input and single-output system is simulated. For the validation of this model, the vibration of the powertrain parts was measured by using triaxial accelerometers attached to the selected vibration sources-a high-pressure pump, fuel rail, injector, and pressure sensor. After calculating the partial coherence between each source based on the virtual model, the vibration contribution of the powertrain system is calculated. This virtual model based on the partial coherence function is implemented to determine the quantitative vibration contribution of each powertrain part.

Vibration Characteristics of a Three-Story Reinforced Concrete Building Before and After Damage (3층 철근콘크리트조 건물의 손상전후의 진동특성)

  • Yoon, Sung-Won;Park, Yong;Ji, Jung-Hwan;Lim, Jae-Hwi;Jang, Dong-Wo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.3
    • /
    • pp.59-66
    • /
    • 2009
  • Dynamic characteristics such as frequency and damping ratio in the ambient state of building has been progressed in domestic and foreign. However, there has not been any deep research of dynamic characteristics of full-scale structure using vibration measurement of the building damaged up to failure. Dynamic characteristics of three-story reinforced concrete building was evaluated before and after it was damaged by using a actuator. Dynamic characteristics is reviewed and compared with previous study. Ambient vibration and human excitation test were applied. After 120mm horizontal displacement by actuator, frequency of long and short direction is reduced to 34.3%, 33.7% and damping ratio is reduced to 36.5%, 19.5% respectively.

  • PDF