• Title/Summary/Keyword: 진동 분석

Search Result 3,886, Processing Time 0.032 seconds

Vibration Response Analysis of the Military Vehicle by Road Test (군용차량 주행 진동응답 분석)

  • Shin, Dong-Jun;Lee, Jong-Hak;Kang, Young-Sik;Choi, Ji-Ho;Kang, Dong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.262-266
    • /
    • 2014
  • Military vehicle equipped with an antenna and a shelter for operating radar has a vibration exposure during driving time. This vibration would have influence on structure of military vehicle critically. In this paper, driving stability of the military vehicle is obtained through the vibration response analysis. And, vibration level of the military vehicle satisfied the military vibration specification through analysis and comparing the MIL-STD-810G. PSD and Grms data obtained by road test can be used for vibration test specification of cabinets and electronic equipment in shelter.

  • PDF

Vibration-based Structural Health Monitoring for Foundation-Mound of Caisson-type Breakwater (케이슨식 방파제 기초마운드의 진동기반 건전성 모니터링)

  • Lee, So-Young;Kim, Jeong-Tae;Park, Woo-Sun;Kim, Hyung-Sub
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.79.1-79.1
    • /
    • 2010
  • 본 연구에서는 케이슨식 방파제 구조물에 대하여 기초마운드의 잠재적인 손상 모니터링에 관한 연구를 수행하였다. 이를 위해 첫째, 케이슨식 방파제 기초마운드의 이상 상태 여부를 판단하기 위하여 진동응답 분석기법을 선정하였다. 둘째, 선정된 기법에 의한 손상 예측 가능성의 검증을 위하여 케이슨식 방파제의 구조모형을 제작하였다. 셋째, 모형케이슨에 대한 유한요소 모델 생생하여 기초마운드의 손상에 따른 진동응답을 분석하였다. 마지막으로, 모형케이슨에 대한 진동실험을 통하여 기초마운드의 손상 예측을 수행하였다.

  • PDF

A Study on the Application of True Maximun Vector Sum and Maximum Vector Sum In Vibration Monitoring of Blast (최대 실벡터합과 최대 벡터합의 적용성에 관한 연구)

  • 강추원;추영래;박현식
    • Explosives and Blasting
    • /
    • v.19 no.2
    • /
    • pp.19-26
    • /
    • 2001
  • 국토의 효율적 활용을 위한 각종 토목.건설공사나 석재 및 골재생산 등을 위해 암반을 굴착함에 있어 다양한 산업용 화약류가 이용되고 있다. 그러나 화약의 사용으로 인해 수반되는 발파진동은 인체 및 구조물 등에 피해를 발생시켜 인근의 주민과 마찰을 일으키고 있다.본 연구에서는 발파진동속도 data를 취합하여 분석 사용함에 있어서 V, T, L 성분의 최대 실벡터합을 사용하는 경우와 최대 벡터합을 사용하는 경우를 비교하여 실제 현장 기험시 적용성을 높이고자 하였다. 진동속도는 최대 실 벡터합에 비해 최대 벡터합에 의해 구해진 진동속도의 크기가 장승근에서는 24.6%, 삼승근에서는 26.1%가 증가하는 것으로 나타났으며, 단일성분의 최대치, 최대 실벡터합, 최대 벡터합의 안전율은 1 : 1.154 : 1.359로 나타났다

  • PDF

A Study on the Characteristics of Noise & Vibration Propagtion in Sanbon Electric Railway Station (산본 전철 역사의 소음.진동 전파 특성에 관한 기초연구)

  • 김준호;김석홍;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.65-69
    • /
    • 1994
  • 전철의 궤도 방진에 의한 소음.진동 저감 효과를 실제 측정에 의해 확인하기 위해서는 궤도 방진 전과 후의 소음.진동 측정 데이타가 필요하다. 그러나 방진 궤도 구조로 설계된 신축 역사는 전철이 운행되지 않으므로 궤도 방진 전의 전철 운행시 발생하는 소음.진동을 측정할 수 없으며 공사완료 후 전철이 운행된다고 하여도 궤도 방진이 되지 않은 상태에서의 소음.진동 측정은 불가능하다. 따라서 본 연구에서는 현재 전철이 운행되고 있고 궤도 방진이 되어 있지 않은 유사한 구조의 산본 전철 역사를 선택하여 소음.진동을 측정, 분석하고 이 데이타를 방진 궤도 구조로 설계된 유사한 구조 신축 역사의 소음.진동을 예측하는데 기초 입력 데이타로 제시하고자 한다.

  • PDF

Vibration monitoring at Vibrating Compaction Works for Ground Improvement (진동 지반다짐 공법에 대한 장기간 진동계측 사례)

  • Kim, Duk-Young;Kim, Sun-Woong
    • Explosives and Blasting
    • /
    • v.33 no.2
    • /
    • pp.40-43
    • /
    • 2015
  • In this case study, a S/W optimized for ground vibration monitoring and analysis was developed. It was applied at vibrating compaction works for the ground improvement needed for the expansion of terminal 5 in Chagi International Airport in Singapore. The possible application of the new vibration analysis software to similar works like pile driving and the capability of long term and real time of the repeated wave vibration at seawalls, the vibration occurring from large structures like super tall buildings, tunnels, long cable hanging bridges, and etc were investigated.

Numerical Analysis on Passive Control of Pressure Oscillation inside Transonic Fighter Weapons Bay (천음속 전투기 무장창 압력 진동의 수동 제어에 관한 수치해석 연구)

  • Yun, Won-Hyeok;Seo, Gang;Kim, Jong-Am
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.387-392
    • /
    • 2013
  • 본 연구에서는 천음속 전투기 무장창 내부의 압력 진동을 제어하기 위해 F-111의 무장창을 2차원 공동(Cavity)으로 모델링하고, EDISON_전산열유체 시스템을 활용하여 공동의 형상 변화에 따라 발생하는 유동 특성을 분석하였다. 최근의 전투기들은 항력 감소와 스텔스 기능을 위해 무기를 기체 안에 내장하는데, 덮개를 열 때 발생하는 공동 형상에 의해 강한 압력 진동이 유발된다. 이러한 진동은 무장창과 주변 기계 장치에 구조적 진동을 일으키고 고장 또는 파괴를 유발하므로, 근본적인 해결책이 필요한 중요한 문제이다. 본 연구에서는 진동의 원인이 되는 전단층(Shear layer) 불안정성을 해결하기 위해 기존에 연구된 형상(Leading edge extension 및 Ramp)과 본 연구에서 새로 제안한 Ramp extension을 적용해 보았다. 그 결과 압력 진동의 원인이 되는 유동 특성이 줄어들고 압력 진동 역시 감소했음을 관찰할 수 있었다.

  • PDF

Quantitative Evaluation of Vibration of Structure by Aircraft Noise and Installation Criteria of Building in Air bases (비행장 소음에 의한 건축물의 진동량 정량평가 및 건축물 설치 기준에 관한 연구)

  • Ahn, Sang-Whoon;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.310-318
    • /
    • 2011
  • Due to the lack of a noise and vibration survey for military air bases, noise and vibration are not taken into consideration for new installations, which has resulted in a number of problems, including the separation of tiles. Furthermore, it is not possible to establish appropriate counter-vibration plans to minimize damage resulting from vibration on structures, since no standard is in place when location for residence areas, including military quarters, is determined. In this context, this research includes a noise and vibration survey, on which basis a quantitative evaluation model for vibration of structure by aircraft noise is generated, as well as through linear regression analysis, and suggests installation standards by purpose of structure, minimizing the damage due to noise and vibration, and establishing appropriate counter-vibration plans for future installation and repairs of on-base structures in the military bases.

Modeling of Walking Loads for Floor Vibration Analysis (바닥판 진동해석을 위한 보행하중의 모형화)

  • 김기철;최균호;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.173-188
    • /
    • 2002
  • In General, the measured loads and load-time function suggested by Bachmann iota walking are used for vibration analysis of structures subjected to footstep loads. It is not easy to measure walking loads because they we influenced by various parameters. Therefore, it is needed to model the walking loads that can be applied to structure analysis. Parameter study is used for the walking loads having various walking frequency for vibration analysis of structures under walking loads. In this study, walking loads were measured directly by using a force plate within two load cells, and the parameters of the walking loads were analyzed. The measured walking loads are decomposed into harmonic loads by using the Fouler series. Functional relationship between the walking frequency and the Fourier coefficients can be derived from the coefficients of harmonic loads obtained by the decomposition process, and the walking loads were formulated. It is possible to apply the venerated walking loads easily or conveniently by the proposed equation to the analysis of a structure subjected to walking loads.

Characteristics of Near-field Ground Vibration in Tunnel Blasting using Electronic Detonators (전자뇌관을 이용한 터널발파의 근거리 지반진동 특성)

  • Kim, Yong-Pyo;Kim, Gab-Soo;Son, Young-Bok;Kim, Jae-Hoon;Kim, Hee-Do;Lee, Jun-Won
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.76-86
    • /
    • 2013
  • In order to control tunnel blast vibration for adjacent facilities using electronic detonator, Understanding about the characteristics of near-field ground vibration is necessary. The purpose of this paper is to analyze effects of Cut-area and Extension-area vibration in relation to decision of tunnel blast vibration. These data were obtained at the top monitoring positions while ${\bigcirc}{\bigcirc}{\bigcirc}$ tunnel site of "Wonju~Gangneung double railroad section ${\bigcirc}{\bigcirc}$ construction" was passing under the existing road. Thus, tunnel blasting was conducted by tunnel electronic blasting system with 0.01% high delay-time accuracy. It can be possible that not only keeping maximum charge per delay-time but also preventing amplification of vibration which is occurred by delay-time scatter using common detonators. Additionally, V-Cut was changed into Burn-Cut. The results was presented that vibration level of extension-holes were higher than Cut-holes. Therefore, near-field ground vibration can be effectively minimized using electronic detonators in the Cut area. And also more effective way to reduce tunnel blast vibration is full-face blast using electronic detonators.

Analysis and Evaluation of the Effect of Blast-induced Vibration Adjacent to Industrial Facilities (산업시설 근접발파 시 발파진동 영향 분석 및 평가)

  • Kawk, Chang Won;Park, Inn Joon;Kim, Young Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.459-468
    • /
    • 2023
  • Power plant is a kind of basic industrial facility and might cause fatal industrial and human damage. In this study, the characteristics and effect of blast-induced vibration for tunnelling which underpass ○○ power plant in operation were evaluated. Previous blasting cases adjacent to industrial facilities were intensively reviewed, then allowable vibration criteria were suggested. 3 dimensional dynamic numerical analysis based on finite element method was performed to investigate particle velocity and resonance was examined by calculating the predominant frequencies. As a result, particle velocity at pump foundation which is nearest to the source was approached to the allowable criteria, therefore, the modified blasting pattern was newly suggested and confirmed the attenuation effect based on the test blasting. Consequently, appropriated decision-support procedure was established in case of adjacent blasting to industrial facilities.