• Title/Summary/Keyword: 진동한계

Search Result 309, Processing Time 0.028 seconds

Detection of Carp Vitellogenin with Piezoelectric Immunosensor (압전류적 면역센서에 의한 잉어 Vitellogenin 검출)

  • Kim, Nam-Soo;Park, In-Seon;Kim, Woo-Yeon
    • Applied Biological Chemistry
    • /
    • v.49 no.3
    • /
    • pp.254-258
    • /
    • 2006
  • Vitellogenin has been known as a potent biomarker protein for the estrogenic activity in fish exposed to endocrine disruptors. In this study, a piezoelectric immunosensor making use of an anticarp vitellogenin antibody and an AT-cut quartz crystal microbalance as the biological component and transducer was prepared, followed by its application to the analysis of carp vitellogenin as follows. Antibody immobilization was conducted by chemisorption of a thiolated antibody with a heterobifunctional thiolation cross-linker, sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido]hexanoate. The reaction buffer for the immunosensor system was optimized as 0.1 M sodium phosphate (pH 7.4). Concentration-dependent sensor responses were obtained in the vitellogenin concentrations ranging from 0.4864 to 486.4000 nM, with a linear correlation between vitellogenin concentration and frequency shift in double-logarithmic scale. The limit of detection of the immunosensor for carp vitellogenin was presumed as 0.4864 nM.

Near-field limit in positioning the microphone for pressure measurements in using the near-field acoustical holography (근접 음향 홀로그래피에서 음압 측정용 마이크로폰의 근접 거리 한계)

  • Kang, Sung-Chon;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.731-736
    • /
    • 2000
  • The recently developed BEM-based NAH(nearfield acoustical holography) is a useful technique for identifying the sound source of vibrating objects. The acoustic parameters of a sound source can be reconstructed by using the vibro-acoustic transfer matrix, which is determined by means of BEM, and the sound pressure measured in the nearfield. Theoretically, one can come up with a very nice reconstructed result as the field plane gets near to the source surface. However, when a microphone is placed in the very close nearfield of the source surface, the scattering, reflection, or resonance in the gap between the source and the microphone can distort the acoustic field, and therefore, the measured field pressure would differ from the actual one in the absence of the microphone. In order to analyze this problem, the interference effect of the microphone is numerically calculated by using the nonsingular BEM that yields very small error in the nearfield. From this analysis, it is found that the prediction error of the field pressure decreases firstly and then increases as the microphone approaches the vibrating surface from the farfield to the close nearfield. It is noted that the microphone should be separated from the source surface by at least a diameter of the microphone for an error ratio less than 2% in the low frequency range less than about 2.7kHz. This means that if one wants to put a microphone in the very close nearfield. a microphone with small diameter should be used.

  • PDF

Development of a Virtual Reality Glove Improvement Algorithm for Immersive Virtual Reality contents (몰입형 가상현실 콘텐츠를 위한 가상현실 글러브 개선 알고리즘 개발)

  • Song, Eun-Jee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.807-812
    • /
    • 2021
  • In order to be able to interact with the user to experience it as if it were real in virtual reality contents, input/output devices that make them feel the five senses of humans are required . In virtual reality (VR), devices that stimulate sight and hearing are the most representative. For a more realistic experience, suits and gloves that stimulate the sense of touch have recently been released, but there are not many cases applied to actual contents due to the limitation of device . In this paper, we analyze a virtual reality glove that can detect hand movement and touch in a virtual world. Based on the analysis, we propose an algorithm that can sense the intensity of collision with a VR object by tactile sense by improving the UI/UX using the vibration of the feedback method used in the existing virtual reality glove. In addition, the system implemented by the algorithm is applied to an actual case.

Study on sound radiation estimation using a reciprocity technique and p-p method by finite element simulation (상반성 기법과 p-p method를 이용한 구조물 방사소음 유한요소해석 기법 연구)

  • Ji Woo Yoo;Hun Park;Ji Un Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • Sound radiated from a structure in vibration is an important physical characteristic to evaluate vibro-acoustic problem. Although sound radiation power can be typically obtained by intensity measurement, long measuring time and strict measuring condition remain difficult. As an alternative method, simulation-based estimation can be taken into account and its accuracy is known to be acceptable. However, difficulty still lies in that specialized softwares may be necessary to obtain sound radiation power and radiation efficiency. In this context, this study suggests two methods using an ordinary FE method to calculate sound radiation power. They are well-known reciprocity technique and p-p method, which are basically test methods. It is shown that either method can practically estimate sound radiation in the frame of conventional Finite Element Method (FEM). The methods and their corresponding limit are discussed with some results.

Structural Design of SAR Control Units for Small Satellites Based on Critical Strain Theory (임계변형률 이론에 기반한 초소형 위성용 SAR 제어부 전장품 구조설계)

  • Jeongki Kim;Bonggeon Chae;Seunghun Lee;Hyunung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-20
    • /
    • 2024
  • The application of reinforcement design to ensure the structural safety of electronics in small satellites is limited by the spatial constraints of the satellite structure during launch vibrations. Additionally, a reliable evaluation approach is needed for mounting highly integrated devices that are susceptible to fatigue failure. Although the Steinberg fatigue failure theory has been used to assess the structural integrity of electronic devices, recent studies have highlighted its theoretical limitations. In this paper, we propose a structural methodology based on the critical strain theory to design the digital control unit (DCU) of the X-band SAR payload component for the small SAR technology experimental project (S-STEP), a small satellite constellation. To validate the design, we conducted modal and random analyses using simplified modeling techniques. Based on our methodology, we ultimately demonstrated the structural safety of the electronics through analysis results, safety margin derivation, and functional tests conducted both before and after the launch test.

A Failure Probability Estimation Method of Nonlinear Bridge Structures using the Non-Gaussian Closure Method (Non-Gaussian Closure 기법을 적용한 비선형 교량 구조계의 파괴확률 추정 기법)

  • Hahm, Dae-Gi;Koh, Hyun-Moo;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.25-34
    • /
    • 2010
  • A method is presented for evaluating the seismic failure probability of bridge structures which show a nonlinear hysteretic dynamic behavior. Bridge structures are modeled as a bilinear dynamic system with a single degree of freedom. We regarded that the failure of bridges will occur when the displacement response of a deck level firstly crosses the predefined limit state during a duration of strong motion. For the estimation of the first-crossing probability of a nonlinear structural system excited by earthquake motion, we computed the average frequency of crossings of the limit state. We presented the non-Gaussian closure method for the approximation of the joint probability density function of response and its derivative, which is required for the estimation of the average frequency of crossings. The failure probabilities are estimated according to the various artificial earthquake acceleration sets representing specific seismic characteristics. For the verification of the accuracy and efficiency of presented method, we compared the estimated failure probabilities with the results evaluated from previous methods and the exact values estimated with the crude Monte-Carlo simulation method.

Dynamical Analysis of the Mooring Vessel System Under Surge Excitations (선박 계류시스템의 종방향 외력하의 비선형 동적거동 해석)

  • Lee, Sang-Do;You, Sam-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.140-145
    • /
    • 2018
  • This paper deals with the dynamical analysis of a two-point mooring vessel under surge excitations. The characteristics of nonlinear behaviors are investigated completely including bifurcation and limit cycle according to particular input parameter changes. The strong nonlinearity of the mooring system is mainly caused by linear and cubic terms of restoring force. The numerical simulation is performed based on the fourth order Runge-Kutta algorithm. The bifurcation diagram and several instability phenomena are observed clearly by varying amplitudes as well as frequencies of surge excitations. Stable periodic solutions, called the periodic windows, can be obtained in succession between chaotic clouds of dots in case of frequency ${\omega}=0.4rad/s$. In addition, the chaotic region is unexpectedly increased when external forcing amplitude exceeds 1.0 with the angular frequency of ${\omega}=0.7rad/s$. Compared to the cases for ${\omega}=0.4$, 0.7rad/s, the region of chaotic behavior becomes more fragile than in the case of ${\omega}=1.0rad/s$. Finally, various types of steady states including sub-harmonic motion, limit cycle, and symmetry breaking phenomenon are observed in the two-point mooring system at each parameter value.

Characteristic Validation of High-damping Printed Circuit Board Using Viscoelastic Adhesive Tape (점탄성 테이프를 적용한 고댐핑 적층형 전자기판의 기본 특성 검증)

  • Shin, Seok-Jin;Jeon, Su-Hyeon;Kang, Soo-Jin;Park, Sung-Woo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.383-390
    • /
    • 2020
  • Wedge locks have been widely used for spaceborne electronics for mounting or removal of a printed circuit board (PCB) during integration, test and maintenance process. However, it can basically provide a mechanical constraint on the edge of the board. Thus, securing a fatigue life of solder joint for electronic package by limiting board deflection becomes difficult as the board size increases. Previously, additional stiffeners have been applied to reduce the board deflection, but the mass and volume increases of electronics are unavoidable. To overcome the aforementioned limitation, we proposed an application of multi-layered PCB sheet with viscoelastic adhesive tapes to implement high-damping capability on the board. Thus, it is more advantageous in securing the fatigue life of package under launch environment compared with the previous approach. The basic characteristics of the PCB with the multi-layered sheet was investigated through free-vibration tests at various temperatures. The effectiveness of the proposed design was validated through launch vibration test at qualification level and fatigue life prediction of electronic package based on the test results.

Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame (중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험)

  • 이한선;우성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.241-252
    • /
    • 1998
  • The objective of the research stated herein is to observe the actual responses of a low-rise nonseismic moment-resisting reinforced concrete frame subjected to varied levels of earthquake ground motions. First, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used and the model was manufactured according to the similitude law. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelations (PGAs) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The lateral accelerations and displacements at each story and local deformations at the critical reginos of the structure were measured. The base shear was measured by using self-made load cells. Before and after each earthquake simulation test, free vibration tests were performed to find the change in the natural period and damping ratio of the model. The test data on the global and local behaviors are interpreted. The model showed the linear elastic behavior under the Taft N21E motion with the PGA if 0.12g, which represents the design earthquake in Korea. The maximum base shear was 1.8tf, approximately 4.7 times the design base shear. The model revealed fairly good resistance to the higher level of earthquake simulation tests. The main components of its resistance to the high level of earthquakes appeared to be 1) the high overstrength, 2) the elongation of the fundamental period, and 3) the minor energy dissipation by inelastic deformations. The drifts of the model under these tests were approximately within the allowable limit.

Study on Seismic Analysis and Test for Seismic Qualification of 245kV GIS (245kV 가스절연개폐장치의 내진성능 실증을 위한 시험 및 해석)

  • Kim, Yu-Gyeong;Kwon, Tae-Hoon;Jeong, Yeong-Jin;Kim, Hong-Tae;Kim, Young-Joong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.715-722
    • /
    • 2013
  • Gas insulated switchgear is large-sized electric equipment for providing a reliable supply of electric power. Recently, seismic tests of electric equipment using a shaking table have been mandated because seismic performance has become an increasingly important issue. However, basic analysis methods continue to be used because some electric equipment is too large for shaking table facilities. Thus, a reliable analysis method should be developed for large-scale electric equipment. This study aims to evaluate the seismic qualification of a 245kV GIS in accordance with IEEE-693 and to validate the analysis method by comparing it with test results. Both the test and the analysis showed that the 245kV GIS has proper seismic safety. Furthermore, the differences between the analysis and the test results are less than 10% for an accurately given mass, stiffness, and input acceleration. It is expected that this study can be used for the seismic qualification of large-scale electrical structures.