• Title/Summary/Keyword: 진단촬영대

Search Result 134, Processing Time 0.032 seconds

Enhancement of Image Quality Using Detector Filter (검출기 필터를 이용한 화질의 향상)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Kim, Min-Hye;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.451-456
    • /
    • 2016
  • Radiation dose to patient is unavoidable when diagnosis is carried out using X-ray. Radiation diagnosis using dual energy X-ray was examined to verify the possibility of medical applications by SNR and image scoring. The dual energy X-ray was realized by combining together two image plates and filter of 0.5 mm thick Cu or Al. Under one X-ray exposure, contrast enhanced image was obtained using two images of image plates. The enhanced image showed higher SNR and image score compared to the first image which was the image recorded with the first image plate. The dual energy X-ray technique would be a very useful method for obtaining higher SNR image and for realizing very low dose, and could be applied to medical applications.

The Utility of $^{18}F$-FDG PET/CT for Following Up Head and Neck Cancer (두경부암 환자의 추적관찰에서 $^{18}F$-FDG PET/CT의 유용성)

  • Chung, Eun-Jae;Baek, Seung-Kuk;Woo, Jeong-Soo;Kwon, Soon-Young;Jung, Kwang-Yoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.178-182
    • /
    • 2010
  • 서 론 : 두경부암의 예후에 가장 중요한 인자는 진단시 병기와 치료 후 재발의 유무이다. 따라서, 재발 병변을 조기에 발견하는 것이 매우 중요하다. 본 연구에서는 두경부암 환자의 추적 관찰에서 $^{18}F$-FDG PET/CT의 유용성에 대해 알아보고자 하였다. 대상 및 방법 : 2004년 4월부터 2008년 8월까지 고려대 안암병원에서 두경부암으로 치료를 완료한 후 추적관찰이 가능하였던 88 예의 환자를 대상으로 하였다. 환자는 본원의 두경부암 추적관찰 양식에 따라 술 후 6, 12개월째 $^{18}F$-FDG PET/CT를 시행하였으며, 원발부위 및 경부 재발, 원격전이와 중복암의 진단에 있어 $^{18}F$-FDG PET/CT의 민감도, 특이도, 양성예측율, 음성예측율을 평가하였고, 기존의 추적관찰 방법과 이를 비교하였다. 결 과 : 원발부위 재발의 진단에 있어 민감도, 특이도, 양성예측율, 음성예측율은 각각 95%, 97%, 90%, 98% 였다. 경부전이 재발의 진단에 있어서는 각각 94%, 98%, 83%, 99%였으며, 원격전이 및 이차암 진단에 있어서는 94%, 100%, 100%, 99%였다. 원발부위 재발은 고식적인 진단 방법, 원격전이와 이차암은 $^{18}F$-FDG PET/CT가 진단에 의미있게 유리하였다. 결 론 : $^{18}F$-FDG PET/CT는 두경부암의 추적관찰 과정에서 재발 여부를 판정하는데 있어 매우 유용하며, 특히 원격전이 및 이차암의 발견에 있어 유용하다. 그러나, 위양성 및 위음성의 가능성으로 고식적인 진단 방법과 병행해야 진단의 효과를 높힐 것으로 생각된다.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Transthoracic Fine Needle Aspiration Biopsy in Localized Pulmonary Lesions: Diagnostic Accuracy and Complications (국소적 흉부 병변에서 세침 흡입 생검의 진단 성적 및 합병증)

  • Yang, Suck-Chul;Kim, Yeon-Soo;Kim, Soon-Kil;Kim, Tae-Wha;Lee, Kyung-Sang;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Jeon, Seok-Chol;Lee, Jung-Dal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.685-694
    • /
    • 1995
  • Introduction: Transthoracic fine needle aspiration biopsy(TNAB) has shown to be a resonably safe, simple, and accurate procedure in diagnosis of intrathoracic lung lesions. We reviewed the results of 1,005 TNAB of chest lesions performed on 930 patients with 20 or 22-gauze needles over a period of 10 years. Methods: From November 1983 to June 1995, 1,005 cases in 930 patients with an undiagnosed lung lesion underwent TNAB at the Hanyang University Hospital: 66% were men and 34% were women. Most of the patients were 40~60 years old and the youngest patient was 3 years of age. Result: 540 patients had various malignant chest lesions and 322 patients had benign pulmonary lesions. The diagnostic accuracy of TNAB was 96.1 percent in malignant diseases with one false positive result and 90.1% in benign diseases. A definitive diagnosis was not obtained in the remaining 68 patients. The most common diagnoses among 519 malignancy chest lesions with TNAB were the following: squamous cell lung carcinoma, 31.7%; adenocarcinoma, 24.7%; small cell lung carcinoma, 16.7%; metastatic cancer, 14.2%; large cell lung carcinoma, 6.2% and so on. Complications included pneumothorax in 12.3% necessitating chest tube drainage in 0.6%. Minor hemoptysis occurred in 3.6%. There was no death directly attributable to the procedure. Conclusion: We concluded that TNAB permits a direct approach to all kinds of localized lung lesions with a high degree of accuracy and without major complications.

  • PDF

Diagnosis with Ultrasound for Rib Fractures in the Golf (골프 운동중 발생한 늑골 골절의 초음파 진단)

  • Lim, Che-Joon;Youn, Te-Hyun;An, Ki-Yong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.50-54
    • /
    • 2008
  • Purpose: In most cases, the main cause of chest or back pain during playing golf is rib fractures. This kind of rib fractures can be easily overlooked in plain radiographs. The purpose of this article is to clarify the value of the ultrasound in detecting rib fractures. Materials and Methods: We compared the findings of chest-X rays (anteroposterior, left or right lateral, both oblique view) with those of the ultrasound in 56 patients between the ages of 20th & 60th who were diagnosed rib fractures. Their chief complaints were chest or back pain which developed during playing golf. The results were analyzed statistically. Results: Among 56 cases of rib fractures, 34 cases were diagnosed with initial X-rays. 51 cases were diagnosed with ultrasound. The sensitivity of radiograph and ultrasound were 60.71% & 91.07%, respectively. Dignosis was ultrasound with statical significance whereas radiography did not(p=0.0004). Conclusion: It was concluded that ultrasound is a valuable tool in the diagnosis of the rib fractures which were undetected with X-rays during playing golf.

  • PDF

Delayed Diagnosis of Cardiac Tamponade That Was Caused by Intramural Hematoma of the Ascending Aorta -A case report- (상행대동맥 벽내 혈종에 의해 발생한 심낭 압전의 지연 진단 - 1예 보고 -)

  • Hwang, Yoo-Hwa;Song, Suk-Won;Yi, Gi-Jong
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.194-198
    • /
    • 2010
  • Intramural hematoma of the aorta (IMH) is the precursor or a variant of a classic aortic dissection where hemorrhage occurs within the aorta wall in the absence of an initial intimal tear. IMH has a high rate of mortality and morbidity. The optimal therapy for IMH is uncertain, yet the involvement of the ascending aorta is usually considered as an indication for surgery due to the associated risk of rupture or cardiac tamponade. We report here on a case of a 71-year-old man who presented with syncope. Because of misdiagnosis, he underwent computed tomography (CT) after 5 hrs from arriving to the ER. Computed tomography of the aorta revealed intramural hematoma of the ascending aorta with cardiac tamponade. He also had vascular complications such as acute renal failure and visceral ischemia. We performed emergency graft replacement of the total arch and ascending aorta. He was discharged without complication on postoperative day 14.

The Study on Clinical Conditions and Skin Dose of Upper-Gastrointestinal X-ray Fluoroscopy (위장 X선 투시검사에 따른 실태 및 선량에 관한 연구)

  • Kim, Sung-Chul;Ahn, Sung-Min;Jang, Sang-Sup
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • This study examined present conditions of upper-gastrointestinal X-ray fluoroscopy and patient skin dose. The authors elected 21 equipments to check the X-ray equipment and exposure factor of fluoroscopy & spot exposure in university hospitals, hospitals, and clinics where perform upper-gastrointestinal X-ray fluoroscopy more than five times every day in Incheon areas. The amount of patient's skin dose during upper-gastrointestinal X-ray fluoroscopy was measured by ionization chamber.

  • PDF

Valve Leaflet Escape of Edwards Duromedics Mechanical Valve - A Case report - (Edwards Duromedics 기계판막엽 탈출 - 1례 보고 -)

  • 윤영남;유경종
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Edwards Duromedics mechanical valve was introduced into clinical use in 1982 and is still being used today after several modifications. Valve-related complications after mechanical valve replacement are thiombo-embolism, endocarditis, valve malfunction, valve leaflet escape and fracture. Incidence of valve leaflet escape is very low. A 40 year-old male patient who had undergone mitral replacement with a 31mm Edwards Duromedics mechanical valve(model

Giant Pseudoaneurysm of Ascending Aorta complicating Recurrent Mediastinitis after Gardiac Surgery (반복된 종격동염 치료후 상행 대동맥에 발생한 거대 가성 대동맥류)

  • Kang, Jun-Gyu;Lee, Chul-Ju;Hong, Jun-Wha;Choi, Ho;So, Dong-Mun;Tak, Seung-Jae
    • Journal of Chest Surgery
    • /
    • v.34 no.3
    • /
    • pp.252-255
    • /
    • 2001
  • 본 30세 여환은 류마치스성 심장판막질환 진단하네 승모판막 및 대동맥판막 치환술 시행후 종격동염 발생하여 지속적 종격동 세척 및 3주간의 항생제 치료후 퇴원하였다. 외래 추적중 다시 감염 및 염증소견 보여 입원하여 혈액배양검사와 흉부전산화 단층촬영시행하였다. 검사상 종격동염의 이후 3주간의 항생제 치료에도 염증 소견이 지속되어 다시 시행한 흉부 전산화단층촬영상 상행대동맥에 거대 가성대동맥류소견보여 재개흉술을 시행하여 초저체온 완전 순환정지 하에 가성대동맥류를 절제한 후, 우심낭편을 이용하여 대동맥 성형술을 시행하였다. 수술후 환자는 순조롭게 회복하였으며 현재 외래에서 추적관리하고 있다.

  • PDF

Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit (진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가)

  • Im, In-Chul;Lee, Sang-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.250-255
    • /
    • 2009
  • This study performed and evaluated the performance test in 40 general X-ray units among diagnostic X-ray units, which were being used in hospitals of gyeongsangnam-do gimhae-si through X-ray tube variable limiting device ability test, the light field and X-ray field alignment test and collimation and beam alignment test of diagnostic X-ray unit. The results are as followings: In a variable beam limiting device ability test, the result of maximum X-ray field test showed that 4(10%) of were incongruent while the result of minimum X-ray field test represented that 5(12.5%) of were incongruent. The result of the light field and X-ray field alignment test showed 23(57.5%) of were within 2% of maximum permissible level and the other 17(42.5%) units were misalignment. The result of beam alignment test represented that 11(27.5%) coincided and another 11(27.5%) within $0.5^{\circ}$ respectively, 10(25%) were $0.6^{\circ}-1.5^{\circ}$ intervals, 7(17.5%) were $1.6^{\circ}-3^{\circ}$ and 1(2.5%) were more than $3^{\circ}$.