• Title/Summary/Keyword: 진단영상 시스템

Search Result 449, Processing Time 0.03 seconds

A Design and Implementation of XML DTDs for Integrated Medical Information System (통합의료정보 시스템을 위한 XML DTD 설계 및 구현)

  • 안철범;나연묵
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.40 no.6
    • /
    • pp.106-117
    • /
    • 2003
  • The advanced medical information systems usually consist of loosely-coupled interaction of independent systems, such as HIS/RIS and PACS. To support easier information exchange between these systems and between hospitals, and to support new types of medical service such as teleradiology, it becomes essential to integrate separated medical information and allow them to be exchanged and retrieved through internet. This thesis proposes an integrated medical information system using XML. We analyzed HL7 and DICOM standard formats, and designed an integrated XML DTD. We extracted information from HL7 messages and DICOM files and generated XML document instances and XSL stylesheets based on the proposed XML DTD. We implemented the web interface for the integrated medical information system, which supports data sharing, information exchange and retrieval between two different standard formats. The proposed XML-based integrated medical information system will contribute to solve the problems of current medical information systems, by enabling integration of separated medical informations and by allowing data exchange and sharing through internet. The proposed system with XML is more robust than web-based medical information systems developed by using HTML, because XML itself provides more flexibility and extensibility than HTML.

Vapor Recognition Using Image Matching of Micro-Array Sensor Response from Portable Electronic Nose (휴대용 전자 후각 장치에서 다채널 마이크로 센서 신호의 영상 정합을 이용한 가스 인식)

  • Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.64-70
    • /
    • 2011
  • Portable artificial electronic nose (E-nose) system suffers from noisy fluctuation in surroundings such as temperature, vapor concentration, and gas flow, because its measuring condition is not controled precisely as in the laboratory. It is important to develop a simple and robust vapor recognition technique applicable to this uncontrolled measurement, especially for the portable measuring and diagnostic system which are expanding its area with the improvements in micro bio sensor technology. This study used a PDA-based portable E-nose to collect the uncontrolled vapor measurement signals, and applied the image matching algorithm developed in the previous study on the measured signal to verify its robustness and improved accuracy in portable vapor recognition. The results showed not only its consistent performance under noisy fluctuation in the portable measurement signal, but also an advanced recognition accuracy for 2 similar vapor species which have been hard to discriminate with the conventional maximum sensitivity feature extraction method. The proposed method can be easily applied to the data processing of the ubiquitous sensor network (USN) which are usually exposed to various operating conditions. Furthermore, it will greatly help to realize portable medical diagnostic and environment monitoring system with its robust performance and high accuracy.

The Feasibility Study of MRI-based Radiotherapy Treatment Planning Using Look Up Table (Look Up Table을 이용한 자기공명영상 기반 방사선 치료계획의 타당성 분석 연구)

  • Kim, Shin-Wook;Shin, Hun-Joo;Lee, Young-Kyu;Seo, Jae-Hyuk;Lee, Gi-Woong;Park, Hyeong-Wook;Lee, Jae-Choon;Kim, Ae-Ran;Kim, Ji-Na;Kim, Myong-Ho;Kay, Chul-Seung;Jang, Hong-Seok;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.237-242
    • /
    • 2013
  • In the intracranial regions, an accurate delineation of the target volume has been difficult with only the CT data due to poor soft tissue contrast of CT images. Therefore, the magnetic resonance images (MRI) for the delineation of the target volumes were widely used. To calculate dose distributions with MRI-based RTP, the electron density (ED) mapping concept from the diagnostic CT images and the pseudo CT concept from the MRI were introduced. In this study, the look up table (LUT) from the fifteen patients' diagnostic brain MRI images was created to verify the feasibility of MRI-based RTP. The dose distributions from the MRI-based calculations were compared to the original CT-based calculation. One MRI set has ED information from LUT (lMRI). Another set was generated with voxel values assigned with a homogeneous density of water (wMRI). A simple plan with a single anterior 6MV one portal was applied to the CT, lMRI, and wMRI. Depending on the patient's target geometry for the 3D conformal plan, 6MV photon beams and from two to five gantry portals were used. The differences of the dose distribution and DVH between the lMRI based and CT-based plan were smaller than the wMRI-based plan. The dose difference of wMRI vs. lMRI was measured as 91 cGy vs. 57 cGy at maximum dose, 74 cGt vs. 42 cGy at mean dose, and 94 cGy vs. 53 at minimum dose. The differences of maximum dose, minimum dose, and mean dose of the wMRI-based plan were lower than the lMRI-based plan, because the air cavity was not calculated in the wMRI-based plan. These results prove the feasibility of the lMRI-based planning for brain tumor radiation therapy.

The Design of Fault Tolerant System for Semantic Web based Visual Media Retrieval Framework (분산 시각미디어 검색 프레임워크를 위한 결함허용 시스템 설계)

  • Jin, Hyu-Jeong;Shim, J.Y.;Kim, S.C.;Won, J.H.;Kim, Jung-Sun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10b
    • /
    • pp.228-232
    • /
    • 2006
  • Ontology를 이용한 분산 시각미디어 검색 프레임워크인 HERMES(The Retrieval Framework for Visual Media Service)[1][2]는 보다 정확한 시각미디어 정보를 제공하고 웹서비스(Web Services)를 적용하여 HERMES/Provider[1][2]의 자율성을 보장한다. 웹기반의 분산 환경에서 Visual Media Data에 대한 지능적인 검색을 위하여 Meta Data와 Ontology를 이용하고 이기종간 통신을 위한 웹서비스를 제공하는 HERMES/ Broker[1][2]에서 예상치 못한 문제가 발생할 경우 문제를 해결할 수 있는 방법이 제시되지 않았다. 일반적으로 웹 서비스를 제공하는 서버에서 발생되는 결함은 해당 웹 서비스를 이용하여 개발되는 어플리케이션의 갑작스런 중단이나 오류의 원인이 된다. 따라서 결함을 해결할 수 있는 대책이 필요하며 HERMES의 Broker 서버 또한 웹 서비스의 결함이 발생하더라고 이를 효과적으로 해결하여 클라이언트에게 웹 서비스를 정상적으로 제공할 수 있는 결함허용 시스템 도입이 매우 중요하다. 때문에 HERMES 프레임워크가 클라이언트에게 신뢰성과 안정성이 보장된 웹 서비스의 제공을 위해서 Broker 서버에서 발생할 수 있는 결함을 효과적으로 극복할 수 있는 메커니즘이 필요하다. 본 논문에서는 Broker 서버 에서 웹 서비스와 관련된 결함이 발생하더라고 올바르게 운영될 수 있으며 분산 이미지 검색 프레임워크인 HERMES의 구조적 특성에 적합한 결함허용 시스템 설계 기법을 제안하여 HERMES 프레임워크가 클라이언트에게 투명성 있는 서비스를 제공하고 높은 신뢰성과 안정성이 확보될 수 있도록 구성하고자 한다. Query 수행을 여러 서버로 분산처리하게 함으로써 성능에 대한 신뢰성을 향상 시킬 수 있는 Load Balancing System을 제안한다.할 때 가장 효과적인 라우팅 프로토콜이라고 할 수 있다.iRNA 상의 의존관계를 분석할 수 있었다.수안보 등 지역에서 나타난다 이러한 이상대 주변에는 대개 온천이 발달되어 있었거나 새로 개발되어 있는 곳이다. 온천에 이용하고 있는 시추공의 자료는 배제하였으나 온천이응으로 직접적으로 영향을 받지 않은 시추공의 자료는 사용하였다 이러한 온천 주변 지역이라 하더라도 실제는 온천의 pumping 으로 인한 대류현상으로 주변 일대의 온도를 올려놓았기 때문에 비교적 높은 지열류량 값을 보인다. 한편 한반도 남동부 일대는 이번 추가된 자료에 의해 새로운 지열류량 분포 변화가 나타났다 강원 북부 오색온천지역 부근에서 높은 지열류량 분포를 보이며 또한 우리나라 대단층 중의 하나인 양산단층과 같은 방향으로 발달한 밀양단층, 모량단층, 동래단층 등 주변부로 NNE-SSW 방향의 지열류량 이상대가 발달한다. 이것으로 볼 때 지열류량은 지질구조와 무관하지 않음을 파악할 수 있다. 특히 이러한 단층대 주변은 지열수의 순환이 깊은 심도까지 가능하므로 이러한 대류현상으로 지표부근까지 높은 지온 전달이 되어 나타나는 것으로 판단된다.의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{99m}Tc$-transierrin이 감염 병소의 영상진단에 사용될 수

  • PDF

An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray (산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가)

  • Yoon, Yongsu
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.533-542
    • /
    • 2017
  • In diagnostic radiology, the imaging system has been changed from film/screen to digital system. However, the method for removing scatter radiation such as anti-scatter grid has not kept pace with this change. Therefore, authors have devised the indirect flat panel detector (FPD) system with net-like lead in substrate layer which can remove the scattered radiation. In clinical context, there are many radiographic examinations with angulated incident X-ray. However, our proposed FPD has net-like lead foil so the vertical lead foil to the angulate incident X-ray would have bad effect on its performance. In this study, we identified the effect of vertical/horizontal lead foil component on the novel system's performance and improved the structure of novel system for clinical usage with angulated incident X-ray. Grid exposure factor and image contrast were calculated to investigate various structure of novel system using Monte Carlo simulation software when the incident X-ray was tilted ($0^{\circ}$, $15^{\circ}$, and $30^{\circ}$ from the detector plane). More photons were needed to obtain same image quality in the novel system with vertical lead foil only then the system with horizontal lead foil only. An optimal structure of novel system having different heights of its vertical and horizontal lead foil component showed improved performance compared with the novel system in a previous study. Therefore, the novel system will be useful in a clinical context with the angulated incident X-ray if the height and direction of lead foil in the substrate layer are optimized as the condition of conventional radiography.

Incidence and Prognostic Factors of Radiation Pneumonitis in NSCLC Treated with Intensity Modulated Radiation Therapy(IMRT) (세기조절방사선치료(IMRT)로 치료한 비소세포폐암 환자에서의 방사선 폐렴)

  • Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.35-44
    • /
    • 2008
  • Purpose: To evaluate the incidence and prognostic factors of treatment-related pneumonitis in non-small-cell lung cancer(NSCLC) patients treated with intensity modulated radiation therapy(IMRT). Materials and Methods: One-hundred-five patients with NSCLC treated with IMRT between 1 August 2004 and 30 November 2006 were analyzed retrospectively. The mean age of patients was 62.9 years, and squamous carcinomas were confirmed in 81 patients(77%). Sixty-six patients(62.9%) were classified as stage III, and 59 patients had lesions in the right lung. Twenty-seven patients were treated with a dose of 3,060 cGy preoperatively, and 10 patients were given a dose of 5,040 cGy postoperatively. Sixty-eight patients received a dose of 7,020 cGy for curative intent. Sixty-eight patients were treated with the use of the CORVUS planning system and 37 patients were treated with the use of the ECLIPSE planning system. Results: Of 105 patients, 21 patients(20%) had abnormal radiological findings, but only seven patients(6.7%) required treatment for radiation pneumonitis. Six of the seven patients had other serious lesions, including a bronchioesophageal fistula(one patient), recurrence in the treatment field(two patients), brain metastasis(one patient) and lung-to-lung metastasis(two patients); all of these patients died within 19 months after radiation treatment. Sixteen patients(23.5%) that received planning with the CORVUS system had abnormal lung findings. Five patients(13.5%) had abnormal lung findings with the use of the ECLIPSE planning system. Other prognostic factors such as perioperative radiation therapy, a volume over 10% of the V20 volume in the right lung, were also statistically significant. Conclusion: This retrospective analysis suggests that IMRT could be a beneficial treatment modality for the reduction of radiation pneumonitis in NSCLC patients. However, the higher incidence of abnormal radiological findings in perioperative patients treated with relatively lower doses($3,060{\sim}5,040$ cGy) suggest the need for judicious treatment planning in preoperative or postoperative treatment.

Production and Application of the Dose Calculation Program which used MS EXCEL and Bit System (MS EXCEL 및 Bit system을 이용한 피부선량 계산 프로그램의 제작 및 응용)

  • Kim, Sung-Chul;Kim, Chong-Yeal
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.39-43
    • /
    • 2009
  • The medical diagnostic examination using ionizing radiation has improved the patients' life and brought revolution in medical examination along with the mechanical development. However, the development of medical imaging systems has also been the reason to increase the patients' exposure for ionizing radiation. ICRP recommends that each country adopts diagnostic reference levels depending on regional and national situations. The Korea Food & Drug Administration suggested the dosimetry measurement guideline for patients in 2007. Nonetheless, in reality, it is hard to know the skin dose of the patients when applying a x-ray since there is no radiation dosimeter in most of clinical situation. Therefore, this study sets a program based on the bit system to figure out easily the skin dose of a patients using MS Excel program in the PC setting. The results showed 10% better outcome.

  • PDF

Construction of a Standard Dataset for Liver Tumors for Testing the Performance and Safety of Artificial Intelligence-Based Clinical Decision Support Systems (인공지능 기반 임상의학 결정 지원 시스템 의료기기의 성능 및 안전성 검증을 위한 간 종양 표준 데이터셋 구축)

  • Seung-seob Kim;Dong Ho Lee;Min Woo Lee;So Yeon Kim;Jaeseung Shin;Jin‑Young Choi;Byoung Wook Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1196-1206
    • /
    • 2021
  • Purpose To construct a standard dataset of contrast-enhanced CT images of liver tumors to test the performance and safety of artificial intelligence (AI)-based algorithms for clinical decision support systems (CDSSs). Materials and Methods A consensus group of medical experts in gastrointestinal radiology from four national tertiary institutions discussed the conditions to be included in a standard dataset. Seventy-five cases of hepatocellular carcinoma, 75 cases of metastasis, and 30-50 cases of benign lesions were retrieved from each institution, and the final dataset consisted of 300 cases of hepatocellular carcinoma, 300 cases of metastasis, and 183 cases of benign lesions. Only pathologically confirmed cases of hepatocellular carcinomas and metastases were enrolled. The medical experts retrieved the medical records of the patients and manually labeled the CT images. The CT images were saved as Digital Imaging and Communications in Medicine (DICOM) files. Results The medical experts in gastrointestinal radiology constructed the standard dataset of contrast-enhanced CT images for 783 cases of liver tumors. The performance and safety of the AI algorithm can be evaluated by calculating the sensitivity and specificity for detecting and characterizing the lesions. Conclusion The constructed standard dataset can be utilized for evaluating the machine-learning-based AI algorithm for CDSS.

Terahertz Wave Technologies for Biomedical and Security Application (생체의료 및 보안분야 응융을 위한 테라헤르츠 기술)

  • Paek, M.C.;Kwak, M.H.;Jun, D.S.;Kim, S.I.;Kang, S.B.;Ryu, H.C.;Kim, K.C.;Ryu, B.H.;Kang, K.Y.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.5
    • /
    • pp.106-122
    • /
    • 2010
  • 생체의료 및 보안검색 응용을 위한 테라헤르츠파 기술에 대하여 조사하였다. 테라헤르츠파는 기존의 X-선이나 초음파, 적외선, 밀리미터파 등에 비하여 독특한 특성을 가지고 있어 새로운 분광 및 영상기술을 확립할 가능성을 가지고 있다. 테라헤르츠 기술의 발전과 더불어 생체의료분야에서는 암진단, 치과질환 및 바이오칩 등에서 큰 시장을 형성할 것으로 전망되며, 보안검색분야는 공항, 항만, 지하철, 우편물 취급 등의 공공부문에서부터 군사목적에 이르기까지 응용이 가능하다. 최근 수 년 동안 소형, 경량 및 저가격의 테라헤르츠 시스템이 개발되면서 시장전망에 크게 높아졌다. 초기에는 공공시설 및 대형 병원에서 시작하여, 기술적 안정성 및 시장 활성화에 의한 경제성이 확보되면 민간 부문의 시장으로 크게 파급될 것으로 가대된다.

Shape and Motion Visualization of the Left Ventricle using a Dynamic Gaussian Blob Model (동적 가우시안 블럽 모델을 이용한 좌심실의 형태 및 운동 가시화)

  • Choi, Soo-Mi;Kim, Myoung-Hee
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.9
    • /
    • pp.768-776
    • /
    • 2000
  • 본 논문에서는 심혈관 조영영상으로부터 좌심실의 형태 및 운동을 가시화하기 위해 기하학적 정보와 물리적 정보를 통합한 동적 가우시안 블럽(dynamic gaussian blob)모델을 개발하였다. 동적 가우시안 블럽 모델은 superellipsoid에 3차원 가우시안 형태함수를 갖는 단일 유한요소를 통합한 것으로, 좌심실에 작용되는 가상적인 힘에 의해 형태를 적하하고, 심박동 전 주기에서의 운동을 추적한다. 또한 벽 운동 정도에 따라 다른 색을 지정하여 볼 수 있도록 함으로써 벽 운동에 이상이 있는 부위를 육안으로 쉽게 판별할 수 있도록 하였다. 이와 같은 좌심실의 동적.색체 가시화는 형태가 변황되는 심장질환이나 허혈이나 심근경색증처럼 심실벽 운동에 이상이 있는 질환의 진단을 도울 수 있다.

  • PDF