• Title/Summary/Keyword: 직접 접촉식

Search Result 137, Processing Time 0.023 seconds

Performance Analysis of Water Direct Contact Air Conditioning System (물 직접접촉식 공기조화장치의 성능해석)

  • Yoo, S.Y.;Kwon, H.K.;Song, J.;Kim, K.Y.;Park, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF

Performance Analysis of Water/Air Direct Contact Air Conditioning System (물-공기 직접접촉식 공기조화장치의 성능해석)

  • 유성연;권화길;김광영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

A Numerical Study on Heat Transfer Characteristics in a Spray Column Direct Contact Heat Exchanger (분사칼럼식 직접접촉열교환기의 열전달특성에 관한 수치적 연구)

  • 강용혁;김남진;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.735-744
    • /
    • 2000
  • In order to define the heat transfer characteristics in a spray column direct contact heat exchanger, the development of a multidimensional numerical model and computational algorithm is essential to analyze the inherent multidimensional characteristics of a direct contact heat exchanger. In the present study, it has been carried out numerical calculations using a two-dimensional model for operation of a direct contact heat exchanger. Such operational and system parameters as the injection velocity, void fraction, aspect ratio and injection temperature of each fluid are examined thoroughly to assess their influence on the performance of a spray column. Analyzed results has shown that our two-dimensional model predicts the heat transfer phenomena well in a spray column.

  • PDF

A Study on a Heat Transfer Characteristics of Direct Contact Heat Exchanger for Steam Condensation According to Various Cooling Water Flow and Internal Pressure(The Purpose of Combination with LNG Evaporator) (증기응축용 직접접촉식 열교환기의 냉각수 유량과 내부압 변화에 따른 열전달 특성연구(LNG 기화기와의 조합목적))

  • Lee, B.C.;Han, S.T.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.153-160
    • /
    • 1991
  • Heat transfer characteristics of a direct contact heat exchanger utilizing sieve trays and spray nozzles for steam condensation for the purpose of combining with a LNG evaporator have been investigated with various cooling water flow rates and different vacuum pressures within the heat exchanger for the purpose of steam condensation. Temperature profiles and the volumetric overall heat transfer coefficients in a direct contact heat exchanger have been obtained for comparisons. The results show that the temperature differences between cooling water and steam along the direct contact heat exchanger height are rapidly decreasing and the volumetric overall heat transfer coefficients of the exchanger improves greatly as the inside vacuum pressure increases. The values of the overall heat transfer coefficients at P=-680mmHg have been increased significantly compared with at atmospheric pressure. At given pressure conditions, it is found that the values of average volumetric overall heat transfer coefficients for the sieve tray are found to be approximately 10% higher than those of the spray nozzle.

  • PDF

Reaction Characteristics of Oxygen Carrier Perticle for Chemical-Looping Combustor in Fixed Bed and Pressurized Fluidized Bed (고정층과 가압유동층에서 매체순환식 가스연소기 산소공여입자의 반응특성)

  • 류호정;배달희;진경태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.173-177
    • /
    • 2002
  • 두 개의 유동층 사이를 순환하는 금속매체(Metal or Metal oxide)를 이용하여 공기에 의한 금속매체의 산화와 기체연료(H$_2$, CO, CH$_4$등)에 의한 금속산화물의 환원반응이 별개의 반응기에서 일어나게 하는 새로운 개념의 연소기술인 매체순환식 가스연소기술은 공기와 기체연료를 직접 접촉시켜 반응하는 기존의 가스연소기에 비해 많은 장점을 가지고 있다.(중략)

  • PDF

The contactless elevator button using the electrostatic capacity (정전 용량을 이용한 비접촉식 엘리베이터 버튼)

  • Bang, Gul-Won
    • Journal of Industrial Convergence
    • /
    • v.19 no.6
    • /
    • pp.67-72
    • /
    • 2021
  • The elevator installed in the building consists of an elevator call button and an input button for selection to the target floor. The elevator button is input only when the elevator user directly presses it. Such passenger input can be infected with an infectious disease due to contamination of the button. A non-contact button is required as a means for solving this problem, which detects the proximity of an object by applying a capacitive method. It implements a function of measuring the body's body temperature by attaching an infrared heat sensor, and provides a sterilization function of a button by attaching a UV-LED. A button was selected, a body temperature was measured through an infrared temperature measurement sensor, and UV-LED was turned on and sterilized when there was no user. The contactless elevator button is expected to be effective in preventing infectious diseases as it can prevent infection of viruses carrying infectious diseases and can detect body temperature to select positive patients of CIVID 19.

A Study on TFT-LCD Cell Aging Electronic-Powered Devices (TFT-LCD Cell Aging 전자구동장치에 관한 연구)

  • Kim, Hyo-Nam
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.363-366
    • /
    • 2011
  • 3D 디스플레이 시장이 커지면서 TFT-LCD TV 자동화 라인 생산 공정을 3D LCD TV 생산 공정으로 변환하여 대량 생산할 경우, 기 설치된 자동화 생산라인의 H/W 부분에는 특별한 투자가 이루어질 거라 판단되지 않고 있다. 하지만 3D LCD Module 검사 등의 S/W 적인 부분은 현재의 기 설치된 TFT-LCD Module 검사장비로는 검사가 불가능하여, 추가적인 투자가 이루어질 것이라 판단되고 있다. 이와 관련하여 본 연구에서는 TFT-LCD 제조공정의 효율적인 기술을 제안하고자 한다. 첫째는 TFT-LCD를 Cell상태에서 직접 구동하는 구동회로 기술과 사용 장소가 Clean Room이므로 개별적 구동 Pallet에 비접촉식으로 전원을 공급할 수 있는 비접촉식 급전장치에 대한 기술이다.

  • PDF

A REID privacy protect scheme based on mobile (모바일 기반의 RFID 프라이버시 보호 기법)

  • Kim, Il-Jung;Choi, Eun-Young;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.17 no.1
    • /
    • pp.89-96
    • /
    • 2007
  • Radio Frequency Identification system based on EPC(Electronic Product Code) Network Environment can read or write information of tagged objects, using Rf signals without direct contact. This advantage which is to provide storage ability and contactless property is better than Bar-code system. Mobile RFID system which integrates Mobile system with RFID system will provide new additional service to users. However, an advantage for obtaining information of objects using RF signal causes personal privacy problem. In this paper, we propose techniques that can protect personal privacy based on mobile. Our scheme provides privacy protection of users and is more efficiently than another application service.

Development of a dispersion coefficient method using a drone-based spatio-temporal hyperspectral image (드론기반 시공간 초분광영상을 활용한 분산계수 산정기법 개발)

  • Gwon, Yeonghwa;Han, Eunjin;Kim, Dongsu;You, Hojun;Kim, Youngdo;Kwon, Siyoone
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.112-113
    • /
    • 2021
  • 하천으로 유입되는 오염물질은 유수의 흐름에 따라 이송되며 혼합된다. 이러한 오염물질의 해석을 위해서는 확산 또는 분산계수 산정이 필요하다. 오염물질의 거동과 관련된 실험적 연구는 방사선 동위원소와 형광성 물질을 이용하여 수행되어 왔으나, 추적자 실험은 많은 비용 및 인력을 요하며, 고정식으로 설치한 계측장비로부터 수집한 시계열 농도자료만을 이용하여 분석하기 때문에 공간적 분포에 대한 자료 취득은 어렵다는 한계가 있다. 하천의 오염물질을 모니터링하기 위해서는 공간을 이동하는 입자의 관점에서 물리량을 표현하는 Lagrangian 방식보다 특정 위치에서 물리량 변화를 표현하는 Eulerian 방식이 적합하다. 그러나 드론을 활용한 하천원격탐사 연구의 대부분은 이동식 플랫폼으로 활용되어 특정 시간에 공간적 분광특성의 분포 파악이 한정적이며, 동일 지점에서 분광특성의 시간적 변화를 파악할 수 없다. 따라서 본 연구에서는 기존의 면단위를 측정하는 이동식 플랫폼의 한계를 극복하고 하천 모니터링에 적합한 Eulerian 방식을 적용하기 위하여 CCTV 형태의 고정식 초분광촬영 플랫폼을 도입하였다. 본 연구에서는 하천으로 유입되는 오염물질의 거동을 분석하기 위하여 자연하천에서 형광성물질인 Rhodamine WT를 이용하여 추적자 실험을 수행하였으며, 접촉식 센서를 활용한 농도측정과 동시에 드론과 초분광센서를 활용하여 CCTV 형태의 고정식 초분광영상을 획득하였다. 실험결과 도출된 전통적인 방식의 분산계수 산정과 시공간 초분광영상을 활용한 분산계수 산정을 비교하여 오염물질 거동 분석에 초분광영상 활용의 가능성을 검토하였다. 본 연구에서 제시한 드론기반 시공간 초분광영상 기법을 교량이나 기타 하천구조물에 초분광 센서를 설치하여 CCTV형식으로 활용할 경우, 공단이나 하·폐수 처리장 등의 점오염원이 밀집해 있는 지역에 직접 설치하여 화학사고의 감지 및 오염물질의 유출 확인 및 조류, 부유사 등의 다양한 수질항목의 농도 변화 감지가 가능하고, 수심변화 감지로 장기적으로 활용할 경우 특정 지점에서의 하상변동 조사가 가능하다. 또한, 오염물질의 유출 사고 발생 등의 사람이 직접 접근이 불가능한 지역에 드론을 활용하여 초분광센서를 이용한 오염물질 감지가 가능할 것으로 판단된다.

  • PDF

드럼식 세탁기의 진동/소음 저감 대책

  • 박정수;김형균
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.881-887
    • /
    • 1997
  • 우리가 일상생활에서 사용하는 가전제품 중에서 소음 진동이 발생하여 생활에 영향을 미치는 제품으로 세탁기를 들 수 있다. 세탁기의 종류는 회전하는 축의 방향에 의해 수직축(vertical axis)과 수평축 (horizontal axis) 방식으로 나누며 국내, 일본및 동남아시아 등에서 사용하는 펄세이터식(pulsator type) 세탁기와 미국을 비롯한 미주에서 사용하는 애지테이터식(agitator type)세탁기는 전자에 속하고 유럽에서 사용하는 드럼식(drum type) 세탁기는 후자에 속한다. 드럼 세탁기의 장점은 물을 적게 사용하고, 삶는 세탁이 가능하며, 건조 기능을 갖고 있으므로 별도의 건조기가 필요없어서 공간을 절약하는 것이다. 또 빨래가 펄세이터나 애지테이터 등의 교반체와 직접 접촉하지 않기 때문에 빨래의 마모가 적다. 드럼식 세탁기의 단점으로는 가격이 펄세이터식이나 애지테이터식에 비해서 비싸고, 무게가 무거우며, 탈수시에 소음과 진동이 심하다. 특히 탈수시 발생하는 소음과 진동은 이방식의 세탁기의 가장 큰 약점이다. 지금까지는 드럼식 세탁기의 진동 소음을 감소시키려는 적극적인 노력이 없었는데, 볼밸런스를 적용한 드럽 세탁기를 개발하여 소음과 진동을 획기적으로 감소시켰다.

  • PDF