• Title/Summary/Keyword: 직접 가열식 가열로

Search Result 31, Processing Time 0.022 seconds

A Study of Optimal Distribution of Gas Temperature in Directly-Fired Reheating Furnace (직접 가열식 가열로 내 최적 분위기온도 분포 해석에 관한 연구)

  • Jeong, Eui-Soo;Shim, Sung-Min;Kim, Young-Deuk;Kang, Deok-Hong;Kim, Woo-Seung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2122-2125
    • /
    • 2008
  • Because the reheating furnace consumes a large amount of energy to heat up the slabs, it is very important to find an optimal temperature patterns in the furnace for energy saving as well as uniform target temperature at the exit of the furnace. In this study, the temperature profiles in the slab are determined by solving the transient one-dimensional heat conduction equation in conjunction with boundary conditions with total heat exchange factors. The optimal temperature patterns are obtained to minimize the fuel consumption with satisfying the predetermined constraint conditions. The design optimization is performed by using a genetic algorithm and the optimal results are validated with results obtained from the PIDO tool, called as P.I.A.n.O.

  • PDF

Classification and Applications of Direct Contact Condensation Heat Exchanger (직접접촉응축 열교환기의 분류 및 응용)

  • 오후규;김성규
    • Journal of the KSME
    • /
    • v.35 no.7
    • /
    • pp.638-646
    • /
    • 1995
  • 직접접촉 얼교환 기술은 냉각탑, 접촉급수 가열기 및 공기분리기 등과 같은 장치에 예전부터 이용되어 왔는데, 그 주요한 적용이유는 가열유체와 수열유체의 사이에 일어나는 전열이 일반 열교환기와는 달리 고체벽(금속 열전달표면)을 통과하지 않고 열교환을 함으로써, 종래의 열교 환기에 비하여 상대적으로 설비의 간단화, 부식 및 스케일 부착문제가 경감됨에 따른 적은 유 지보수비 및 높은 열전달률을 얻을수 있는 이점이 있으며, 저 온도차에서의 효율적인 사용이 가능하기 때문이다. 이 글에서는 직접접촉응축 현상의 장점을 이용하는 직접접촉식 교환기의 구조와 형태, 그리고 그 응용분야에 대해서 알아보고자 한다.

  • PDF

A Theoretical Study on the Photothermal Displacement Method for Wave Shape of Pump Beam (가열빔의 파형에 따른 광열변위법에 대한 이론적 연구)

  • 전필수
    • Journal of Energy Engineering
    • /
    • v.9 no.2
    • /
    • pp.138-145
    • /
    • 2000
  • 고체재료의 열확산계수나 열전도계수와 같은 열물성을 비접촉식 방법으로 측정하기 위하여 광열변위법에 대한 이론적인 해석을 수행하였다. 가열빔의 파형을 코사인파, 삼각파 그리고 사각파로 가정하여 2차원 열전도 방정식과 열탄성 방정식의 엄밀해를 구하였고, 이를 가열빔으로부터 직접 구한 실제파의 결과와 비교하였다. 코사인파의 결과가 다른 파형에 비하여 실제파와 가장 유사한 것으로 보아 비교적 해석이 복잡한 실제파를 코사인파로 가정하여도 무방하다.

  • PDF

A Study on the Flow Conditions of the Combustion Air Heater Outlet for the Supersonic Combustion Experiment (초음속 연소 실험을 위한 연소식 공기 가열기 출구 유동 조건 실험 연구)

  • Lee, Eun Sung;Han, Hyung-Seok;Lee, Jae Hyuk;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.88-97
    • /
    • 2022
  • In this study, a vitiated air heater was designed and manufactured to supply high-temperature and high-pressure air to the ground test apparatus of a direct-connected supersonic combustor, and an experiment was performed to verify the target design point. By installing wedges at the upper boundary, lower boundary and center of the nozzle exit of the vitiated air heater, it was confirmed that the Mach number satisfies the 2.0 level, and the pressure of the combustion chamber was also satisfactory compared to the design point. In the case of temperature, the measured temperature deviation was large due to the degree of exposure of the thermocouple and the slow response characteristics. After that, the isolator was connected to the rear of the vitiated air heater, and the Mach number was measured in the same method, and the Mach number at the center of the isolator eixt was slightly reduced to 1.8~1.9.

저준위 방사성폐기물 유리화에 관한 타당성 분석

  • 박종길;안희진;김연숙;송명재
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.829-834
    • /
    • 1995
  • 최근 전세계적으로 활발히 연구가 진행되고 있는 저준위 방사성폐기물 유리화에 관한 타당성을 조사하기 위해 여러 형태의 유리용융로에 대한 기술성을 분석하고, 기술성 분석에서 선택한 용융로를 이용한 3종류의 새로운 처리개념에 대한 경제성 분석을 수행하였다. 기술성 분석 대상 용융로는 프랑스 CEA/SGN 사의 직접유도가열식 저온로, 미국 VECTRA 사의 수직전극가열식 저온로, 미국 SEG사의 용응금속로 미국 Retech 사의 플라즈마토치 용융로이다. 기술성 분석결과 직접유도가 열식 저온로와 플라즈마토치 용융로를 병행하여 적용하는 것이 바람직하다는 결론을 얻었다. 이 용융로들을 이용한 3종류의 처리개념에 대해 처분부피, 처분단가에 따른 처분비, 처리비를 산정하고 현재 적용하고 있는 처리개념과 상호 비교하였다. 비교 결과 유리화 기술을 적용하는 것이 경제적이라 것과 현재 보다 80 %이상 처분부피를 감소시킬 수 있다는 것을 알 수 있었다.

  • PDF

Remediation of Petroleum-Contaminated Soil by a Directly-Heated Thermal Desorption Process (직접 가열식 열탈착 공정을 이용한 유류오염토양의 정화)

  • Min, Hyeong-Sik;Yang, In-Ho;Jeon, Sang-Jo;Kim, Han-S.
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.62-70
    • /
    • 2009
  • A field soil highly contaminated with petroleum hydrocarbons (JP-8 and diesel fuels) was employed for its remediation by a lab-scale thermal desorption process. The soil was collected in the vicinity of an underground storage tank in a closed military base and its contamination level was as high as 4,476 ppm as total petroleum hydrocarbon (TPH). A lab scale directly-heated low temperature thermal desorption (LTTD) system of 10-L capacity was developed and operated for the thermal treatment of TPH contaminated soils in this study. The desired operation temperature was found to be approximately $200-300^{\circ}C$ from the thermal gravimetric analysis of the contaminated field soils. The removal efficiencies higher than 90% were achieved by the LTTD treatment at $200^{\circ}C$ for 10 min as well as at $300^{\circ}C$ for 5 min. As the water content in the soils increased and therefore they were likely to be present as lumps, the removal efficiency noticeably decreased, indicating that a pre-treatment such as field drying should be required. The analysis of physical and chemical properties of soils before and after the LTTD treatment demonstrated that no significant changes occurred during the thermal treatment, supporting no needs for additional post-treatments for the soils treated by LTTD. The results presented in this study are expected to provide useful information for the field application and verification of LTTD for the highly contaminated geo-environment.

플라즈마에 의한 웨이퍼 가열과 Si 식각 속도의 변화 모델링

  • No, Ji-Hyeon;Hong, Gwang-Gi;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.291-291
    • /
    • 2011
  • 플라즈마에 노출된 재료 표면의 온도 증가는 다음과 같은 요인에 의해서 결정된다. 이온의 충돌에 의한 역학적 에너지, 이온의 중성화, 라디칼의 안정화에 의한 에너지 방출(잠열, latent heat), 플라즈마에서 방출된 빛의 흡수. 이중 식각을 위한 기판 바이어스에 의해서 주로 결정되는 이온 충돌 에너지와 잠열의 방출이 300 mm wafer용 유도 결합 플라즈마 식각 장치에서 소스 전력과 바이어스 전력에 따라서 어떻게 변화하는지 전산 유체 역학 모사 프로그램인 CFD-ACE를 이용하여 상용 식각 장비인 AMAT사의 DPS II를 대상으로 온도 분포의 변화를 계산하였다. 실험 결과와 비교를 위하여 다섯 곳에(상, 하, 좌, 우, 중심) 열전대를 부착한 온도 측정 웨이퍼를 기판의 위치에 설치하고 여러 가지 실험 조건에 대해서 온도의 변화를 측정하였다. Ar 10 mTorr에서 2열 병렬 안테나의 전력을 300 W에서 시간에 따른 온도의 변화를 측정하였다. 이때 wafer의 평균 온도는 $28.9^{\circ}C$에서 $150^{\circ}C$까지 12분 내에 상승하였으며 최고 온도에 도달한 다음에는 거의 일정하게 유지 되었다. Si의 식각에서 온도의 영향을 가장 크게 받는 반응은 F 라디칼에 의한 Si의 직접 식각이며 Arrhenius 식의 형태로 표현하면 0.116*exp (-1250/T)의 형태로 된다. 문헌에 보고된 계수를 이용해서 $29^{\circ}C$의 식각 속도와 플라즈마에 의한 가열 최고 온도인 $150^{\circ}C$ 때의 값을 비교해보면 3.3배의 차이가 난다. 따라서 4%내의 식각 균일도를 목표로 하는 폴리 실리콘 게이트 식각 장비의 설계에서는 플라즈마에 의한 가열 불균일을 상쇄 할 수 있는 히터와 냉각 구조의 최적 설계가 필요하다.

  • PDF

촉매수지식 용존산소 제거설비 - 개발경위와 앞으로의 활용전망

  • 이창소
    • Nuclear industry
    • /
    • v.16 no.2 s.156
    • /
    • pp.47-55
    • /
    • 1996
  • 원자력발전소 2차 계통수중의 용존산소는 증기발생기 뿐만 아니라 터빈 급수가열기와 응축기 등 주요설비 부식의 직접적인 원인으로서, 원자력발전의 경제성 저하 및 원전설비의 안전성에 심각한 문제를 야기시키고 있다. 한국정수공업(주)는 최근 $\ulcorner$촉매수지식 용존산소 제거설비$\lrcorner$를 한국원자력연구소의 기술지원 아래 연구$\cdot$개발하여 고리원자력 1호기에 설치$\cdot$운용중에 있다. 그 개발경위와 활용전망 등을 알아본다.

  • PDF

Numerical Study on the Process of Supersonic Flow Formation in a Direct-Connect Supersonic Combustor (Direct-Connect 초음속 연소기 내 초음속 유동 형성과정에 대한 수치해석)

  • Jeong, Seong-Min;Han, Hyunh-Seok;Sung, Bu-Kyeng;Lee, Eun-Sung;Choi, Jeong-Yoel
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.889-902
    • /
    • 2020
  • In this study, a numerical analysis was performed to confirm the formation of supersonic flow and the stabilization time satisfying the design condition in a Direct-connect supersonic combustor. The process was examined in which the high-pressure gas of vitiation air heater propagates downstream to the supersonic combustor and forms a supersonic flow field. It was confirmed through the analysis of pressure and temperature that the supersonic flow field satisfies the design points of Mach number 2.0 and 1,000 K, and requires a minimum of 4.0 ms for stabilization. These results indicate that the time required for the supersonic flow field stabilization should be taken into account when testing for the supersonic combustion experiment.