• Title/Summary/Keyword: 직류/직류

Search Result 2,505, Processing Time 0.029 seconds

A Novel Method for Calculating the Stroke of LPMSM for Driving Linear Compressor Using High Pass Filter (고역필터를 사용한 선형압축기 구동용 LPMSM의 새로운 스트로크 계산 기법)

  • Ahn, Jung-Ryol;Lee, Hong-Hee;Kim, Heung-Gun;Nho, Eui-Cheol;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Linear compressors with a free piston driven by a linear motor are widely attention in the cooling apparatus such as refrigerator due to the high efficiency The stroke of piston in the linear compressor driven by LPMSM (Linear Permanent-Magnet Synchronous Motor) can be obtained from Integrating the input voltage and current of LPMSM, but it may be diverged due to dc components in the voltage and current. The strategy to prevent the divergence of stroke using both the high-pass filter and do offset compensation was suggested. The equations for the magnitude and phase of the stroke and also dc offset including the stroke are derived as a function of the cut-off frequency of HPF. The accurate stroke of a piston can be calculated by compensating for dc offset. The performance of the newly developed stroke calculation scheme has been verified by experimentally on a linear compressor drive system, where the control was implemented by a 16-bit DSP.

Electrical Properties of 18[kV] ZnO Surge Arrester Stressed by the Mixed DC and 60[Hz] AC Voltages (직류+60[Hz]교류 중첩전압에 대한 18[kV] ZnO 피뢰기의 전기적 특성)

  • Lee, Su-Bong;Lee, Seung-Ju;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.66-72
    • /
    • 2007
  • This paper describes the characteristics of power loss and leakage currents flowing through new and used 18[kV] zinc oxide(ZnO) surge arrester under the mixed DC and AC voltages. The mixed DC and AC voltage generator of 50[kV] peak was designed and fabricated. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K. The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in both I-V curves and R-V curves was observed at the low current region. As a result, the increase of DC component in the mixed voltages causes the increase of resistive component of total leakage current of ZnO surge arrester. Also, in the case of same applied voltage, the leakage current flowing through the used ZnO surge arrester was higher than that of the new ZnO surge arrester.

A Study on the Parameter Identification of a Brushless DC Motor (브러시리스 직류전동기의 파라미터 동정에 관한 연구)

  • 임영철;조경영;정영국;김영민;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.41-50
    • /
    • 1993
  • This paper describes an effort to develop a microcomputer-based parameter identification system for three phase and two phase brushless DC motor. Back EMF equation is derived from back EMF waveform of three phase and two phase brushless DC motor. In this paper, a new identification algorithm for the brushless DC motor parameters by Pasek's technique is developed. It is found that Pasek's equation is valid for the brushless DC motor, too. The results obtained clearly shows that it is possible to implement the identification system for the determination of the brushless DC motor parameters. To minimize errors due to the ripple component in the measured armature current, digital averaging firis employed. The whole identification process of signal generation, measuring, parameter determination is fully automated. The use of the propod method in the parameter identifition system shows that the averaged current curve is in excellent agreement with the estimated current curve. Therefore, this close agreement confirms the validity of this technique.

  • PDF

Regeneration Inverter System for DC Traction with Hormonic Reduction Capability (고조파 저감 능력을 가진 직류전철 회생인버터 시스템)

  • Won, Chung-Yuen;Jang, Su-Jin;Kim, Yong-Ki;Bang, Hyo-Jin;Song, Sang-Hun;Ahn, Kyu-Bok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.96-104
    • /
    • 2004
  • This paper proposes a dc power regenerating systems, which can generate the excessive dc power from dc bus line to ac supply in substations for traction system The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As an regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

The Influence of Distance between Current Supply Points on Potential Drop in DCPD (직류전위차법에서 전류 입출력점 사이 거리가 전위차에 미치는 영향)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.104-107
    • /
    • 2009
  • It was verified that the effect of the distance between current input point and output point on direct current potential drop(DCPD) in the material with two-dimensional surface notch. If the distance between potential drop measuring points was fixed at a certain distance, the potential drop was decreased with increasing the distance between current input and output points. Hence it is the effect way to increase sensitivity in DCPD that the current input and output points should be located near the potential measuring points. DCPD was a useful method for surface crack sizing because the potential drop was proportional to the length of notch. When the current input and output points are located near the potential measuring points, even small length crack can be measured by DCPD technique.

Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor (1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석)

  • Quan, Dao-Van;Le, Tat-Thang;Sung, Hae-Jin;Park, Min-Won;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.31-41
    • /
    • 2018
  • This paper discusses a structure design and thermal analysis of cryogenic conduction cooling system for a high current HTS DC reactor. Dimensions of the conduction cooling system parts including HTS magnets, bobbin structures, current leads, support bars, and thermal exchangers were calculated and drawn using a 3D CAD program. A finite element method model was built for determining the optimal design parameters and analyzing the thermo-mechanical characteristics. The operating current and inductance of the reactor magnet were 1,500 A, 400 mH, respectively. The thermal load of the HTS DC reactor was analyzed for determining the cooling capacity of the cryo-cooler. Hence, we carried out the operating test of conduction cooling system of the 1st stage area with high current flow. The cooper bars was cooled down to 40 K and HTS leads operated stably. As a experiment result, the total heat load of the 1st stage area is 190 W. The study results can be effectively utilized for the design and fabrication of a commercial HTS DC reactor.

A Study on the Supply and Stray Current Distribution of the DC Railway Power System (직류전기철도 급전시스템에서 공급 및 누설전류 분포에 관한 연구)

  • Cho, Woong-Ki;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.160-168
    • /
    • 2010
  • This paper presents the analysis of the current as stray current and supplied current of the substation, on the DC railway power system. In DC railway power supply system, the running rails are usually used as the return conductor(negative-polarity) for traction load current. This condition mainly focuses on economic considerations, since it does not require the installation of an additional return conductor. But, problems of low resistance between the running rails for the return conductor and earth allows a significant part of the return load current to leak into the earth. This current is normally called to as leakage or stary current. This stary currents creates serious problems for any electrified matter in the underground. Therefore, reduction of stray current of the DC railway power supply system is also of direct benefit to the operational and safety aspects of the DC railway systems. In this paper, deal with the analysis of the current distribution on the DC railway power system applied the common grounding system, using SPLIT of CDEGS program.

Effects of Occupation-Based Bilateral Upper Extremity Training and Transcranial Direct Current Stimulation Upper Limb Function in Stroke Patients (작업기반 양측성 상지 훈련과 경 두개 직류 전류 자극이 뇌졸중 환자의 상지 기능에 미치는 영향)

  • Kim, Sun-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.9
    • /
    • pp.520-530
    • /
    • 2020
  • The purpose of this study was to investigate the effects of occupation-based bilateral upper extremity training and transcranial direct current stimulation on upper limb function in stroke patients. The study group was divided into 13 experimental groups with occupation-based bilateral upper extremity training and transcranial direct current stimulation, and 13 controls with only occupation-based bilateral upper extremity training. A total of 4 weeks, 50 minutes, 5 times a week conducted, the patients were tested with Canadian Occupational Performance Measure(COPM), Accelerometer, Fugle-Meyer Assessment(FMA), and Motor Activity Log(MAL). As a result of the study, the experimental group and the control group showed significant improvement in both occupation satisfaction and performance, usage of the affected side and the tendon side, recovery of upper limb function, and quality of movement, In particular, the experimental group showed a significant difference in the amount of the affected side than the control group. Therefore, it was found that the combination of occupation-based bilateral upper extremity training and transcranial direct current stimulation had a positive effect on the recovery of upper limb function in stroke patients.

A Study on the SHE-Based Harmonic Reduction of DC Power Regenerating Systems (SHE방식을 적용한 직류전력 회생시스템의 고조파 저감에 관한 연구)

  • 정우창;강경우;서영민;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.58-64
    • /
    • 2004
  • This paper proposes a novel control scheme for the harmonic reduction of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in subway systems. In the developed regenerating systems controlled by MAC(Modified a-Conduction) method, the order of remaining harmonics are 12k$\pm$1. In SHE(Selected Harmonic Elimination) method proposed in this paper, however, the l1th and 13th harmonics are additionally eliminated. And moreover 23rd harmonics, lowest order harmonics among the remaining harmonics, is eliminated by 23rd AC filter furnished at the output terminals of regenerating systems. To verify the validity of the proposed SHE-based harmonic reduction technique, computer simulations are carried out. Simulation results show that the THDs of output voltages are lower than that of the MAC method and the THDs in the control range are in the range of 0.53-0.68 percents.

A Study on Direct Current Measurement Using Magneto-Optical LMF Method (자기장학 누설자속법을 응용한 직류전류계측법에 관한 연구)

  • Lee, Jin-Yi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2004
  • It is necessary to measure the direct current with a non-contact methodology for the liquid or gas phase, as welt as the conducting metals. This paper described a theoretical consideration and experimental verification for a non-contact quantitative direct current measurement system using the Faraday effect and magnetic flux leakage. The leakage of magnetic flux occurs around a gap when a ferromagnetic core including the discontinuous gap is magnetized. Two large anisotropic domains in a magneto-optical film are occurred by the vertical component of leaked magnetic flux and the domain walls are paralleled to the center of the gap. Here, the symmetrical arrangement of domains are deflected when a vertical magnetic field is applied to the magneto-optical film. The domain wall of the magneto-optical film are relocated when a measuring current passes through the ferromagnetic core. Therefore, a direct current passing through the core can be determined quantitatively by the measurement of moving distance of the domain wall.