• Title/Summary/Keyword: 직각도 측정

Search Result 143, Processing Time 0.029 seconds

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

CRLH Rectangular Waveguide with Balanced Condition above Cut-off Frequency (차단 주파수 이상에서 평형 조건을 만족하는 CRLH 직각 도파관)

  • Kim, Dong-Jin;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.912-918
    • /
    • 2011
  • In this paper, a composite right-/left-handed(CRLH) rectangular waveguide satisfying a balanced condition above the cut-off frequency is presented. The proposed structure consists of one shorted stub and two twisted H-plane irises which produce an effectively negative permeability and permittivity, respectively. The CRLH structure can independently control the series and shunt resonance frequencies of a CRLH transmission line which determine the left-handed(LH) and right-handed(RH) bands due to a minimized coupling between a shorted stub and twisted H-plane irises. Thus, the design of the CRLH waveguide satisfying a balanced condition is possible. To analyze the CRLH structure, a crossly connected equivalent circuit is derived. The simulated and measured results confirm that the proposed CRLH waveguide has a transmission property without a band gap among the LH and RH bands.

The Effect of the Indication of Lengths and Angles on Classifying Triangles: Centering on Correct Answer Rate and Eye Movements (분류하기에서 길이와 직각 표기의 효과: 정답률과 안구운동 분석을 중심으로)

  • Yun, Ju Mi;Lee, Kwang-ho;Lee, Jae-Hak
    • Education of Primary School Mathematics
    • /
    • v.20 no.2
    • /
    • pp.163-175
    • /
    • 2017
  • The purpose of the study is to identify the effect of length and right angle indication on the understanding of the concept of the figure when presenting the task of classifying the plane figures. we recorded thirty three 4th grade students' performance with eye-tracking technologies and analyzed the correct answer rate and gaze duration. The findings from the study were as follows. First, correctness rate increased and Gaze duration decreased by marking length in isosceles triangle and equilateral triangle. Second, correctness rate increased and Gaze duration decreased by marking right angle in acute angle triangle and obtuse triangle. Based on these results, it is necessary to focus on measuring the understanding of the concept of the figure rather than measuring the students' ability to measure by expressing the length and angle when presenting the task of classifying the plane figures.

A Study on Miniaturization of a Log-Periodic Dipole Array Antenna (대수주기 다이폴 배열 안테나의 소형화 연구)

  • Ham, Hyung-Jun;Ryu, Hong-Kyun;Park, Beom-Jun;Park, Young-Ju;Lee, Kyu-Song;Woo, Jong-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.709-720
    • /
    • 2014
  • In this paper, we studied miniaturization of LPDA(Log-Periodic Dipole Array) antenna used for VHF and UHF bands. To miniaturize the LPDA antenna, in this study, the radiation elements in a low frequency were changed into a triangular meander structure which has small current cancelation effect at feed part. For the triangular meander structure, an isosceles triangular and right triangular meander structures were proposed and the LPDA antennas were miniaturized by using the two meander structures. Also, the simulated and measured results were compared for the two miniaturized LPDA antennas. As a result, the isosceles triangular meander and right angle triangular meander structure applied LPDA antennas were reduced up to 60.5 % and 72.4 % compared a basic LPDA antenna, respectively. Consequently, we confirmed that the triangular meander structure is suitable for miniaturization of a LPDA antenna.

Auditory Spatial Arrangement of Object's Position in Virtual and Augmented Environment (가상환경에서의 위치정보 제시를 위한 청각적 공간배열)

  • Lee, Ju-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.326-333
    • /
    • 2011
  • In the present study, we measured the performance (accuracy and reaction time) of the user in the virtual environment with see-through Head-Mounted Display system that includes 3D sound generated through Head-Related Transfer Function (HRTF) to investigate the feasibility of auditory display for a certain object's spatial information. To sum up the results of two experiments, when presenting location information of the object with 3D sound, it is desirable that information arrangement from the user should be an orthogonal pattern which is located with right angle, not a diagonal pattern. Like these results propose that spatial information presentation with 3D sound make the optimal object arrangement of virtual environment possible.

Stable lateral-shearing interferometer for in-line inspection of aspheric pick-up lenses (생산 라인에서의 광 Pick-up용 비구면 대물 렌즈 측정을 위한 안정된 층밀리기 간섭계)

  • 조우종;김병창;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.189-193
    • /
    • 1997
  • Aspheric pick-up lenses are increasingly used in consumer products such as computer and multimedia, as their mass production has become possible owing to the injection molding process. However still much work needs to be done for more effective manufacture of aspheric lenses, one area of which is the in-line inspection of produced lenses. In this paper, we present a lateral-shearing interferometer that has specially been designed to have a high immunity to external vibration and atmospheric disturbance. The interferometer comprises four prisms. They are directly attached to each other using an immersion oil so that relative sliding motions between the prisms are allowed. Their relative displacement can readily generate necessary lateral-shearing and phase-shifting to determine the wavefront of the beam collimated by the lens under inspection. A special phase-measuring algorithm of arbitrary-bucket is adopted to compensate the phase-shifting error caused by the thickness reduction in the immersion oil. Zernike polynomial fitting has done for determinating quantitative aberration of aspheric pick-up lenses. The interferometer built in this work is robust to external mechanical vibration and atmospheric disturbance so that experimental results show that it has a repeatability of less than λ/100.

  • PDF

The Image Position Measurement for the Selected Object out of the Center using the 2 Points Polar Coordinate Transform (2 포인트 극좌표계 변환을 이용한 중심으로부터의 목표물 영상 위치 측정)

  • Seo, Choon Weon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.147-155
    • /
    • 2015
  • For the image processing system to be classified the selected object in the nature, the rotation, scale and transition invariant features is to be necessary. There are many investigations to get the information for the object processing system and the log-polar transform which is to be get the invariant feature for the scale and rotation is used. In this paper, we suggested the 2 points polar coordinate transform methods to measure the selected object position out of the center in input image including the centroid method. In this proposed system, the position results of objects are very good, and we obtained the similarity ratio 99~104% for the object coordinate values.

Patterns of Natural Convection around a Square Cylinder Placed Concentrically in a Horizontal Circular Cylinder (수평원관 내부에 위치한 동축정방형 물체 주위에서의 자연대류특성)

  • Chang, K. S.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.2
    • /
    • pp.147-159
    • /
    • 1982
  • 내부에 정방형, 외부에 원형인 두 정온동심수평관으로 이루어진 폐쇄공간에서 열부력으로 야기된 대류열전달 현상을 연구하였다. 주어진 비정규적 형상에서의 층류 정상 Boussinesq 유동을 해 석하기 위하여, 지구중력방향에 대하여 가능한 두 개의 대칭형 위치에 관하여, Galerkin 유한요 소법을 사용하였다. 이론의 결과를 확증하기 위하여 실험적으로도 온도측정과 유선의 가시화를 수행하였다. 정방형내관의 직각인 선단은 국소 및 총체열전달에 있어서 소극적인 역할을 하지만, 이들로 인한 경계층 유동의 박리는 발생하지 아니함을 보였다. 이 내관의 상부 수평면상에서는 유동속도와 온도구배가 낮기는 하나 확연한 대칭형의 열상승류(Plume)가 가능하였다. 내관의 벽면들이 지구중력방향에 관하여 .+-.45.deg.의 각을 이룰 경우 과류의 중심부가, Rayleigh수가 6.5*$10^{4}$보다 작을 때는 4개, 이보다 클때는 2개가 폐쇄공간 안에서 발생하였다.

Analysis of Electromagnetic Flowmeter Characteristics in Electromagnetic Pump System (전자점프 시스템에서 전자유량계 특성 해석)

  • Yoon, Tae-Kyu;Jeon, Mun-Ho;Kwak, Hee-Sung;Kim, Chang-Eob
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.56-58
    • /
    • 2008
  • 전자유량계는 전자유도법칙을 발견한 패러데이의 원리를 이용한 것이다. 도체가 자장 내에서 운동할 때 그 도체 내 자장 및 운동방향에 서로 직각으로 기전력이 발생하며, 그 크기는 자속밀도와 유속에 비례한다. 본 논문에서는 전자유량계의 측정원리를 이용하여 용융금속 이송용 전자점프 시스템에서 전자유량계의 유량신호를 해석하였다, 또한 유량신호의 크기가 유동과 자속밀도의 크기에 따라 어떻게 영향을 받는지 유동해석을 이용하여 분석하였다.

  • PDF

Deep Drawing of Glass Fiber Reinforced Thermoplastic Composite (유리섬유 강화 열가소성 복합재료 판재의 소성가공)

  • 이중희
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.88-95
    • /
    • 1996
  • 유리섬유가 강화된 열가소성 복합재료 판재의 성형성에 대한 이해를 돕기 위해 이론적 고찰과 실험적 고찰이 행해졌다. 성형시험에서 사용된 형상은 임의의 방향으로 위치한 유리섬유를 중량비로 30% 함유한 폴리프로필렌 재료가 사용되었고, 시험된 형상은 판재의 굽힘성이나 인장성을 측정하는데 널리 사용되는 스위프트컵(Swift flat-bottomed cup)모양이다. 성형시험과 재료시험은 플리프로필렌 Matrix의 유리성 천이온도(Glass transition temperature)와 용융온도 사이에서 행해졌다. 본 연구의 이론과 고찰을 위해서 재료의 평면 방향으로는 동질성을 그리고 그 직각 방향으로는 이질성을 가진 연속체 물질로 가정하여 유도하였다. 이러한 이론적 결과는 실험 결과와 비교되어졌고,이를 통해 시험된 재료의 최적의 성형조건을 제시하였다.

  • PDF