• Title/Summary/Keyword: 지하차도 구조물

Search Result 51, Processing Time 0.028 seconds

A Study on Watertightness Improvement of Hybrid Method Using Polyvinyl Acetate(PVAc) (폴리비닐아세테이트(PVAc)를 이용한 복합공법의 수밀성능 향상에 관한 연구)

  • Ryou, Jae Suk;Song, Il Hyun;Lee, Yong Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.18-24
    • /
    • 2012
  • In this study, hybrid method using polyvinyl acetate (PVAc) which has a strong adhesion and flexibility in which acrylic copolymer chemical-reaction reacts with cement, and is eco-friendly, is to improve the watertightness. The hybrid method is applied applied primarily waterproof stuff comprising silicate system and secondary mortar mixed with PVAc on the concrete surface. And then, in order to evaluate the performance, the properties of bond strength and amount of water absorption were measured. Based on the above experiments, mock-up specimens for field application were fabricated, and then the properties were evaluated as laboratory experiments. As the results, specimens cast from hybrid method using PVAc showed the best results on watertightness and bond strength. And also, with respect to experiment of mock-up specimens, the properties were in agreement with laboratory results. Especially, it could know that PVAc has strengthening effect from the results of the compressive strength. Due to outstanding results of carbonation depth and resistance to chloride ion penetration, it may be applied in weak areas such as underground and marine structures.

Rock Bolt Integrity Assessment in Time-Frequency Domain : In-situ Application at Hard Rock Site (유도파를 이용한 시간-주파수 영역 해석을 통한 록볼트 건전도 실험의 경암지반 현장 적용성 평가)

  • Lee, In-Mo;Han, Shin-In;Min, Bok-Ki;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.5-12
    • /
    • 2009
  • As rock bolts become one of the main support systems in tunnels and underground structures, the integrity of the rock bolts affects the safety of these structures. The purpose of this study is the evaluation of rock bolt integrity using wavelet transforms of the guided ultrasonic waves by using transmission test in the field. After several rock bolts with various defect ratios are embedded into a large scale concrete block and rock mass, guided waves are generated by a piezo disk element and measured by an acoustic emission (AE) sensor. The captured signals are analyzed in the time-frequency domain using the wavelet transform based on a Gabor wavelet. Peak values in the time-frequency domain represent the interval of travel time of each echo. The energy velocities of the guided waves increase with an increase in the defect ratio. The suitable curing time for the evergy velocity analysis is proposed by the laboratory test, and in-situ tests are performed in two tunnelling sites to verify the applicability of rock bolt integrity tests performed after proposed curing time. This study proves that time-frequency domain analysis is an effective tool for the evaluation of the rock bolt integrity.

Model testing of leakage effect due to multi-cell inflater of rapid protection system in subsea tunnel (해저터널 급속차폐시스템의 Inflater 분할구조에 따른 터널 내 차수효율에 대한 실험적 연구)

  • Yoo, Kwang-San;Lee, Ji-Hyun;Kim, Yeon-Deok;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • This paper presents the study of leakage effect due to multi-cell inflater of rapid protection system to protect the possibilities of tunnel damages by flooding threats and unusual leakage to be occurred during and after subsea tunnel construction. Particularly, this protect system should be necessary in subsea tunnel. This research concentrates the physical model tests due to several multi-cell inflater to study protection capacity of leakage between the inflater and tunnel liner. A 27:1 small scale model are used in the model tests. The leakage rate, water pressure and axial displacement of inflater are measured during the model tests. According to the results, the minium leakage rate clearly shows in the case of two-cell inflater compared with in other cases. It is concluded that the results of this research will be very useful to understand the fundamental information of inflater structure design and development the technology of tunnel protection structures in the future.

Properties of Alkali-Activated Cement Mortar by Curing Method (양생 방법에 따른 알칼리활성 시멘트 모르타르의 특성)

  • Kim, Ji-Hoon;Lee, Jae-Kyu;Hyung, Won-Gil
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • Globally, there are environmental problems due to greenhouse gas emissions. $CO_2$ emissions rate of the cement industry is very high, but the continued demand of cement is needed in the future. In this study, in order to reduce the environmental impact of $CO_2$ emissions from cement production. The experiments were carried out for the development of non-sintered cement (have not undergone firing burning) by granulated ground blast furnace slag. In order to compare the characteristics by curing, an experiment was conducted by changing the curing conditions such as atmospheric steam curing, observe the mechanical properties for the measurement of flexural compressive strength by mortar, observe the chemical properties such as acid resistance, $Cl^-$ penetrate resistance and analyzed the mechanism of hydration by XRD, SEM experiments. From the experimental results, as compared with portland cement usually confirm the mechanical and chemical properties excellent, it is expected be possible to apply to the undersea, underwater and underground structures that require superior durability. In addition, based on the excellent compressive strength by steam curing, it is expected to be possible to utilize as a cement replacement material in the secondary product of concrete. In the future, to solve the problem through continued research, it will be expected to reduce the effect of environmental load and to be excellent economics.

A study of Spatial Multi-Criteria Decision Making for optimal flood defense measures considering regional characteristic (지역특성을 고려한 홍수방어대안 제시를 위한 공간 다기준의사결정 기법 적용 방안 연구)

  • Lee, Eunkyung;Ji, Jungwon;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.301-311
    • /
    • 2018
  • Recently, the flood inundation caused by heavy rainfall in urban area is increasing due to global warming. The variability of climate change is described in the IPCC 5th report (2014). The precipitation pattern and hydrological system is varied by climate change. Since the heavy rainfall surpassed the design capacity of the pipeline, it caused great damage in metropolitan cities such as Seoul and Busan. Inundation in urban area is primarily caused by insufficient sewer capacity and surplus overflow of river. Inundation in urban area with concentrated population is more dangerous than rural and mountains areas, because it is accompanied by human casualties as well as socio-economic damage to recover destruction of roads, brides and underground spaces. In addition, various factors such as an increase in impervious area, a short time of concentration to outlet, and a shortage of sewer capacity's lack increase flooding damage. In this study, flood inundation analysis was conducted for vulnerable areas using XP-SWMM. Also, three structural flood prevention measures such as drainage pipeline construction, detention reservoir construction, and flood pumping station construction are applied as flood damage prevention alternatives. The flood data for each alternative were extracted by dividing the basin by grid. The Spatial Compromise Programming are applied using flood assessment criteria, such as maximum inundation depth, inundation time, and construction cost. The purpose of this study is to reflect the preference of alternatives according to geographical condition even in the same watershed and to select flood defense alternative considering regional characteristics.

A study on the significance and structural improvement of the stone chamber tomb by the application of a compound lime - Mortar during the reign of king Sejong in the Joseon Dynasty (조선 세종대 삼물회(三物灰) 도입에 따른 석실릉 구조개선과 의의)

  • SHIN, Jihye
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.223-242
    • /
    • 2022
  • The main purpose of this study is to find out the meaning of structural changes that appeared in the royal tombs of the Joseon Dynasty after the application of a compound lime-mortar(Sammulhoe三物灰: the mortar with lime, sand, ocher). In the early Joseon Dynasty, the royal tomb was constructed by following the system of the stone chamber tomb in the Goryeo Dynasty. However the system of the stone chamber tomb recorded in 『GukJo-OReYi(國朝五禮儀: The five category's formalities in the Joseon Dynasty)』 is very different from that in the Goryeo Dynasty. The biggest difference is that a compound lime-mortar was applied into the system of the stone chamber tomb in order to attempt structural reinforcement. This change reflects King Sejong's willingness to build a dense structure in which water does not permeate the stone chamber when Yeongneung(英陵) was built in 1446(the 28th year of King Sejong's reign). Yeongneung is a complex structure consisting of a stone chamber and compound lime-mortar wall. After constructing a stone chamber, the 1.2m(4尺) thick wall with a compound lime-mortar is additionally constructed outside the stone chamber structure. In 1468(the year of King Yejong's accession), according to the will of King Sejo, the stone chamber system was abolished and the Hyeongung(玄宮: the chamber enshrining a coffin of the deceased king or queen consort) was constructed only by the thick wall with a compound lime-mortar. This change become a primary cause for the royal tomb to be constructed as Hoekyukneung(灰隔陵: the royal tomb with chamber constructed only by the thick wall with compound lime-mortar) in the late Joseon Dynasty. The Hoekyukneung in the late Joseon Dynasty has been constructed with the method of structure and construction for the thick wall with a compound lime-mortar since the complex structure recorded in 『GukJo-OReYi(國朝五禮儀)』. The Hoekuykseoksilneung(灰隔石室陵: the complex structure consisting of a stone chamber and compound lime-mortar wall) is unique tomb style of Joseon Dynasty and become a motive of tomb system(Hoekuykneung) in the late Joseon Dynasty.

Development and Verification of A Module for Positioning Buried Persons in Collapsed Area (붕괴지역의 매몰자 위치측위를 위한 모듈 개발 및 검증)

  • Moon, Hyoun-Seok;Lee, Woo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.427-436
    • /
    • 2016
  • Due to disasters such as earthquakes and landslides in urban areas, persons have been buried inside collapsed buildings and structures. Rescuers have mainly utilized detection equipment by applying sound, video and electric waves, but these are expensive and due to the directional approaches onto the collapsed site, secondary collapse risk can arise. In addition, due to poor utilization of such equipment, new human detection technology with quick and high reliability has not been utilized. To address these issues, this study develops a wireless signal-based human detection module that can be loaded into an Unmanned Aerial Vehicle (UAV). The human detection module searches for the 3D location for buried persons by collecting Wi-Fi signal and barometer sensors data transmitted from the mobile phones. This module can gain diverse information from mobile phones for buried persons in real time. We present a development framework of the module that provides 3D location data with more reliable information by delivering the collected data into a local computer in the ground. This study verified the application feasibility of the developed module in a real collapsed area. Therefore, it is expected that these results can be used as a core technology for the quick detection of buried persons' location and for relieving them after disasters that induce building collapses.

Initial Imperfection and Axial Strength of Struts with Octagonal Hollow Section fabricated from HR Plate (열연강판 팔각강관 버팀보의 초기편심과 축방향 압축강도)

  • Jo, Jae Byung
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Developed in this study were Octagonal-hollow-section(OHS) struts, whose compressive strengths against flexural and local buckling is higher than H-shape or rectangular-hollow-section(RHS) struts with the same unit weight. OHS members are also advantageous in handling and storing compared to circular hollow sections(CHS). OHS members were fabricated from HR Plates by cold forming and fillet welding. 5 numbers of 20m long OHS struts were assembled, each of which consist of two 9.6m long OHS member and two end connection elements made of cast iron. The compressive strength of the OHS strut was evaluated by comparing the test results, design codes and FEM analysis each other. Test results show that all of the struts have almost same or larger compressive strength than Korean Road Bridge Design Code(KRBDC) (2012). The initial imperfections can be estimated by using measured strains and are turned out to be less than L/450 for all the struts tested. The results of FEM analysis show that the variation of initial imperfection has less effects on the compressive strength for struts with vertical surcharge than for those with self-weight only, while the strength decreases as the initial imperfection increases. As the result of this study, the allowable initial imperfection for 20m long OHS struts is recommended to be less than L/350 on job sites.

Case study on the lake-land combined seismic survey for underground LPG storage construction (LPG 지하저장기지 건설을 위한 수륙혼합 탄성파탐사 사례)

  • Cha Seong-Soo;Park Keun-Pil;Lee Ho-Young;Lee Hee-Il;Kim Ho-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.101-125
    • /
    • 2002
  • A lake seismic survey was carried out to investigate possible geohazards for construction of the underground LPG storage at Namyang Lake. The proposed survey site has a land-lake combined geography and furthermore water depth of the lake is shallow. Therefore, various seismic methods such as marine single channel high resolution seismic reflection survey, sonobuoy refraction survey, land refraction survey and land-lake combined refraction survey were applied. Total survey amounts are 34 line-km of high resolution lake seismic survey, 14 lines of sonobuoy refraction survey, 890 m of land refraction survey and 8 lines of land-lake combined refraction survey. During the reflection survey, there were severe water reverberations from the lake bottom obscured subsurface profiling. These strong multiple events appeared in most of the survey area except the northern and southern area near the embankment where seems to be accumulated mainly mud dominated depositions. The sonobuoy refraction profiles also showed the same Phenomena as those of reflection survey. Meanwhile the results of the land-lake combined refraction survey showed relatively better qualities. However, the land refraction survey did not so due to low velocity soil layer and electrical noise. Summarized results from the lake seismic survey are that acoustic basement with relatively flat pattern appeared 30m below water level and showed three types of bedrock such as fresh, moderately weathered and weathered type. According to the results of the combined refraction survey, a velocity distribution pattern of the lake bottom shows three types of seismic velocity zone such as >4.5 km/s, 4.5-4.0km/s and <4.0km/s. The major fault lineament in the area showed NW-SE trend which was different from the Landsat image interpretation. A drilling was confirmed estimated faults by seismic survey.

  • PDF

Manual of River Corridor Survey and Monitoring for Nature-Friendly River Management (자연 친화적 하천관리를 위한 수변조사 및 모니터링 매뉴얼)

  • Ock Giyoung;Woo Hyoseop;Kim Kyuho;Cho Kanghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1269-1273
    • /
    • 2005
  • 자연 친화적 하천관리는 현 치수위주의 하천정비 관행으로 인한 하천의 환경 기능의 훼손을 막고, 제도적으로 자연 친화적으로 하천 사업을 추진하기 위해서 수변조사, 계획, 설계, 시공, 모니터링, 그리고 유지관리 등 일련의 체계적인 절차에 따라 하천 사업을 시행하는 것이다. 특히 이러한 표준 절차 가운데 수변조사는 하천의 특성을 결정짓는 여러 가지 자연적, 인공적 형성과정들과 그 과정들을 지배하는 생태학적 원리들을 파악하여 하천사업의 정비주제와 방향을 설정하는데 도움을 준다. 모니터링은 계획과 설계, 시공을 통해 실시된 하천사업의 효과를 평가하고, 공법적용에 따른 하천의 변화과정을 파악하여 유지관리 및 적응관리를 위한 근거를 제시하는 과정이다. 수변조사 및 모니터링 매뉴얼은 건설교통부가 수행한 '자연친화적 하천정비기법 개발' 의 연구성과로서, 경기도의 탄천, 충청북도의 달천 그리고 경기도 오산천을 대상으로 각 관련분야의 전문가가 참여하여 직접 적용$\cdot$검증한 결과를 바탕으로 제작한 것이다. 이는 하천의 관리 및 하천관련 사업을 자연 친화적으로 수행하기 위하여 필요한 '수변조사'와 '모니터링'에 대한 일반적인 절차와 방법을 체계화 한 것이다. 특히 수변조사 매뉴얼의 경우는 $\ulcorner$하천설계기준$\lrcorner$의 '제12장 하천환경조사'를 보완하는 관계에 있다. 하천설계기준에서 제시한 하천환경조사는 본 수변조사 매뉴얼상과 동일한 절차와 양식을 따르고 있다. 하천설계기준에서 자세하게 기술하지 못한 조사방법, 정리, 분석, 평가에 대한 내용을 구체적으로 적용하여 이를 보완하고 있다.은 안양천 웹페이지(http://anyang.river.or.kr)에서 구현되고 있으며, 앞서 설명한 바와 같이 1단계 프론티어 사업으로 설치된 4개의 하천수위, 2개의 지하수위 관측시설과 함께, 2단계에 (주)웹솔루스에서 자체적으로 설치 운영하고 있는 2개소의 하수관거 모니터링 관측시설, 그리고 안양시에서 운영하고 있는 5개소의 강우관측소와 7개소의 수위관측소를 모두 통합하여 실시간 자료를 제공하고 있다. 수위자료는 10분단위의 텍스트정보와 그래프형태로 지원되며, 검색기간 설정을 통해 원하는 기간내의 자료를 선별, 검색할 수 있다.. 또한 이와 같은 기초적인 정보를 바탕으로 하류하천의 탁수 피해를 최소화할 수 있는 선택취수탑의 운영방안을 수립할 수 있다 본 연구에서는 이를 위해 선택취수탑 주위의 성층흐름을 기존의 실험자료와 수치해석을 통하여 분석하였고, 온도성층구조나 취수구의 위치변화에 따른 방류수 수질특성을 조사하였다.쇄파대(artifical reef)와 같은 완충지대를 갖는 호안을 축조함으로써 월파량을 감소시키는 대안으로 제시하고자 한다. 본 연구 수행을 통해 태풍 내습시 발생 가능한 자연재해에 대한 사전 방지를 목적으로 태풍피해의 원인을 제시하고 이를 해결하여 현재의 방재대책이 항구적인 방재대책으로 전환될 수 있는 방안 마련의 기초 자료로 활용되기를 기대한다., L-arabinose, 및 D-galactose; 제3차(第三次) 가수분해물(加水分解物)(C)에서 L-rhamnose, D-xylose, L-arabinose 및 D-galactose, 비가수분해물(非加水分解物)(C')에서 D-xylose와 D-galactose를 검출(檢出)하였다. (4) 구성당(構

  • PDF