• Title/Summary/Keyword: 지하수-지표수 영향

Search Result 263, Processing Time 0.033 seconds

Coupled Thermal-Hydrological-Mechanical Behavior of Rock Mass Surrounding Cavern Thermal Energy Storage (암반공동 열에너지저장소 주변 암반의 열-수리-역학적 연계거동 분석)

  • Park, Jung-Wook;Rutqvist, Jonny;Ryu, Dongwoo;Synn, Joong-Ho;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • The thermal-hydrological-mechanical (T-H-M) behavior of rock mass surrounding a high-temperature cavern thermal energy storage (CTES) operated for a period of 30 years has been investigated by TOUGH2-FLAC3D simulator. As a fundamental study for the development of prediction and control technologies for the environmental change and rock mass behavior associated with CTES, the key concerns were focused on the hydrological-thermal multiphase flow and the consequential mechanical behavior of the surrounding rock mass, where the insulator performance was not taken into account. In the present study, we considered a large-scale cylindrical cavern at shallow depth storing thermal energy of $350^{\circ}C$. The numerical results showed that the dominant heat transfer mechanism was the conduction in rock mass, and the mechanical behavior of rock mass was influenced by thermal factor (heat) more than hydrological factor (pressure). The effective stress redistribution, displacement and surface uplift caused by heating of rock and boiling of ground-water were discussed, and the potential of shear failure was quantitatively examined. Thermal expansion of rock mass led to the ground-surface uplift on the order of a few centimeters and the development of tensile stress above the storage cavern, increasing the potential of shear failure.

Clinical Outcomes of Thoracic Sympathicotomy for Palmar Hyperhidrosis (수부 다한증에서 흉부교감신경 절제술의 성적)

  • Lee, Jang-Hoon;Lee, Jung-Cheul
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Background: Thoracoscopic R3 sympathicotomy can effectively treat palmar hyperhidrosis. Here, we evaluated post-operative outcomes of patients receiving a thoracoscopic R3 sympathicotomy due to palmar hyperhidrosis. Material and Method: From January 2001 to December 2006, 225 patients were treated with a R3 sympathicotomy, and follow up was completed for 200 patients, with an average follow up period of 51.7 ($11{\sim}80$) months. We measured postoperative hand sweating according to four grades; dry (grade 1), proper (grade 2), light sweating (grade 3), heavy sweating (grade 4) and evaluated patient satisfaction using 4 grades: very good (grade 0), good (grade1), regular (grade 2), and deficient (grade 3). Result: There were no differences in clinical parameters between the compensatory sweating group and the non-compensatory sweating group. There was a 83.5% compensatory sweating rate. The degree of compensatory sweating related to the patient's body mass index and was influenced by the season, environmental temperature, and emotional stress. Conclusion: The satisfaction rate was 61.5%, and the degree of satisfaction related to the development of compensatory sweating. Therefore, reducing compensatory sweating would increase patient satisfaction with R3 sympathicotomies.

Variation of Landslide Risk with Parameters (매개변수에 따른 산사태 위험도의 변화)

  • Lee, Jundae;Kwon, Youngcheul;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.1
    • /
    • pp.15-23
    • /
    • 2018
  • In this study we performed risk evaluation based on parameters using the SINMAP, GIS-based extended program in order to predict ground disaster that is frequent recently. As for the risk evaluation, in order to understand the effects of parameters, we defined that the ranges of internal friction angles and T/R values as important variables had three and four patterns, respectively. The results of the interpretation were compared with those of the existing landslide in order to identify landslide flow and to evaluate the applicability of the parameters. The analysis of the geomorphologic saturated zone showed that the boundary saturated zone and the saturated zone were almost consistent with the site of avalanche of earth and rocks and the area of underground water convergence was correlated to the area where collapse started, indicating that the geomorphologic saturated zone may serve as an index for estimating possibility of landslide when used with slope distribution, colluvial soil, and structures inducing landslide in combination. When the lower limit of the internal friction angle increased more, the upper threshold decreased by 50 to 70% and the influence on the stability index was higher, but the influence was declined within the range of lower wetness index. The analysis of changes based on wetness index range showed that all the groups have similar SI distribution, except for the one in which mean altitude values are applied, indicating that the results are susceptible more by the internal friction angle than by the wetness index.

Analysis Actual Conditions of Arid Progress and Prevention Management of Hwaeom Wetland in Yangsansi (양산시 화엄늪의 산지화 진행실태 및 예방관리 방안)

  • Lee, Soo-Dong;Kim, Sun-Hee;Kim, Ji-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.4
    • /
    • pp.498-511
    • /
    • 2012
  • Mountainous wetland have many species such as II grade endangered species of wild flora and fauna(Drosera rotundifolia) and environmental indicator species(Utricularia racemosa, Habenaria linearifolia, Parnassia palustris, Molinia japonica, etc.). Accordingly, the mountainous wetlands is very important. However, most mountainous wetlands will disappear by natural or artificial aridness processes. Thus, it needs to manage mountainous wetland for protecting from aridness. This study has found out the wetland status of the environmental ecology and aridness processes moreover, it has suggested ways of improving wetland conservation plan and wetland aridness management plan. According to the results of topography structure survey, Hwaeom wetland's altitude is ranged within 750~810m(87.4%), and slope is less than $10^{\circ}$. There was ideally suited mountainous wetland. However, the water supply(1.6 meters depth and 0.8 meters wide) was built on under the wetland. For that reason, there was concerned about the aridness processes by sweeping away peat layer and dropping the water level. The distribution area of hygrophyte was narrowed to 6.7% whereas, woody plants and xerophytic plants was achieved a dominant position. If it leaves the situation as it is, the mountainous wetland will be developed next succession as forest ecosystem. Therefore, in order to sustain the mountainous wetland from aridness, it is set to the base direction of conservation and management as main schemes. Moreover, we have suggested that setting the vegetation conservation and management area which considering a ecological vegetation characteristics, managing the ecotone vegetation, setting the buffer zone for protection of ecological core areas, protecting the mountainous wetland indicator species and designating the management vegetation. In conclusion, in order to sustain and maintain a soundly wetland ecosystem, it needs to several management of wetlands damage factors. 1) suppression of the excessive groundwater to basin, 2) stabilization of wetland via hydrologic storage, 3) suppression of changing and transforming wetland into forest by succession via management of xerophytic plants.

Site Monitoring System of Earthquake, Fault and Slope for Nuclear Power Plant Sites (원자력발전소의 부지감시시스템의 운영과 활용)

  • Park, Donghee;Cho, Sung-il;Lee, Yong Hee;Choi, Weon Hack;Lee, Dong Hun;Kim, Hak-sung
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.185-201
    • /
    • 2018
  • Nuclear power plants(NPP) are constructed and operated to ensure safety against natural disasters and man-made disasters in all processes including site selection, site survey, design, construction, and operation. This paper will introduce a series of efforts conducted in Korea Hydro and Nuclear Power Co. Ltd., to assure the safety of nuclear power plant against earthquakes and other natural hazards. In particular, the present status of the earthquake, fault, and slope safety monitoring system for nuclear power plants is introduced. A earthquake observatory network for the NPP sites has been built up for nuclear safety and providing adequate seismic design standards for NPP sites by monitoring seismicity in and around NPPs since 1999. The Eupcheon Fault Monitoring System, composed of a strainmeter, seismometer, creepmeter, Global Positioning System, and groundwater meter, was installed to assess the safety of the Wolsung Nuclear Power Plant against earthquakes by monitoring the short- and long-term behavioral characteristics of the Eupcheon fault. Through the analysis of measured data, it was verified that the Eupcheon fault is a relatively stable fault that is not affected by earthquakes occurring around the southeastern part of the Korean peninsula. In addition, it was confirmed that the fault monitoring system could be very useful for seismic safety analysis and earthquake prediction study on the fault. K-SLOPE System for systematic slope monitoring was successfully developed for monitoring of the slope at nuclear power plants. Several kinds of monitoring devices including an inclinometer, tiltmeter, tension-wire, and precipitation gauge were installed on the NPP slope. A macro deformation analysis using terrestrial LiDAR (Light Detection And Ranging) was performed for overall slope deformation evaluation.

The variation of transition zone between sea water and fresh water with the tidal effect at the coastal rock aquifer (해안가 암반대수층에서 조석효과에 의한 해수와 담수 전이대의 변동 연구)

  • Kim, Sung-Soo;Kang, Dong-Hwan;Kim, Dong-Soo;Choi, Sun-Mi;Chung, Sang-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1904-1908
    • /
    • 2008
  • 본 연구에서는 해안가 암반대수층에서 전기전도도의 수직적인 변화를 관측하여 조석에 의한 해수와 담수 전이대의 특성을 파악하였다. 연구지역은 부경대학교 대연캠퍼스 주변 해안대수층이며, 응회질퇴적암과 안산암 및 안산암질 화산각력암 등이 분포한다. 연구에 이용된 지하수 관측공 (PK1공)은 부경대학교 대연캠퍼스 내 기숙사 동측에 위치하고 있다. 지하수공의 개발심도는 지표 면하 120 m, 케이싱은 지표면하 19 m까지 설치되어 있으며, 내경은 0.2 m로서 해안가에서 180 m 정도 이격되어 있다. 해안대수층 내 해수와 담수 전이대를 파악하기 위하여 관측공 내에 TLC Meter(Model 107, Solinst)를 삽입하여 전기전도도의 수직적인 변화를 지하수공 내 심도 50 m 까지 측정하였다. 전기전도도의 수직적인 관측은 썰물(low tide)일 때, 썰물에서 밀물(high tide)로 될 때 및 밀물일 때로 나누어 총 3회 수행되었다. 전체적인 전기전도도의 분포는 썰물일 때 $630{\sim}47300{\mu}S/cm$, 썰물에서 밀물로 되는 시기에는 $672{\sim}61900{\mu}S/cm$ 및 밀물일 때는 $678{\sim}67900{\mu}S/cm$로 나타났으며, 따라서 밀물일 때가 썰물일 때보다 전기전도도의 농도가 높은 것으로 나타났다. 해수와 담수 전이대의 분포는 썰물일 때 약 $20{\sim}50\;m$, 밀물일 때 약 $20{\sim}38\;m$ 정도로 나타났으며, 이는 밀물 시 해수의 침투로 인해 전이대 하부구간의 농도가 상승하였기 때문이다. 해수와 담수 전이대의 구간을 세분화하여 분석하기 위해, 담수가 우세한 전이대, 주 전이대 및 해수가 우세한 전이대 구간으로 구분하였다. 담수가 우세한 전이대는 썰물과 밀물일 때 모두 지표면하 $20.0{\sim}25.5\;m$ 구간이었으며, 주 전이대에서는 지표면하 $25.5{\sim}25.7\;m$ 정도로 나타났다. 그러나, 해수가 우세한 전이대에서는 썰물일 때 지표면하 $25.7{\sim}50.0\;m$ 구간, 밀물일 때는 지표면하 $25.7{\sim}38.0\;m$ 로서 전이대의 폭이 19 m 정도의 차이를 보였다. 본 연구를 통해 해안가 암반대수층에서 해수와 담수의 전이대는 조석에 의해 영향으로 인해, 썰물 시의 전이대가 밀물에 비해 그 폭이 더욱적음을 확인할 수 있었다.

  • PDF

A Study on Persulfate Oxidation to Remove Chlorinated Solvents (TCE/PCE) (과황산(persulfate) 산화반응을 이용한 염소계 화합물(TCE, PCE) 분해에 관한 연구)

  • Song, Kyoung-Ho;Do, Si-Hyun;Lee, Hong-Kyun;Jo, Young-Hoon;Kong, Sung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.549-556
    • /
    • 2009
  • In situ chemical oxidations (ISCO) are technologies for destruction of many contaminants in soil and groundwater, and persulfate has been recently studied as an alternative ISCO oxidant. Trichloroethylene (TCE) and tetrachloroethylene (PCE) were chosen for target organic compounds. The objective of this study is to demonstrate the influence of initial pH (3, 6, 9, 12), oxidant concentrations (0.01, 0.05, 0.1, 0.3, 0.5 M), and contaminants concentrations (10, 30, 50, 70, 100 mg/L) on TCE/PCE degradation by persulfate oxidation. The maximum TCE/PCE degradation occurred at pH 3, and the removal efficiencies with this pH condition were 93.2 and 89.3%, respectively. The minimum TCE/PCE degradation occurred at pH 12, and the removal efficiencies were 55.0 and 31.2%, respectively. This indicated that degradation of TCE/PCE decreased with increasing the initial pH of solution. Degradation of TCE/PCE increased with increasing the concentration of persulfate and with decreasing the concentration of contaminants (TCE/PCE). The optimum conditions for TCE/PCE degradation were pH 3, 0.5 M of persulfate solution, and 10 mg/L of contaminant concentration. At these conditions, the first-order rate constants ($k_{obs}$) for TCE and PCE were 1.04 and 1.31 $h^{-1}$, respectively.

A Method of Developing a Ground Layer with Risk of Ground Subsidence based on the 3D Ground Modeling (3차원 지반모델링 기반의 지반함몰 위험 지반 레이어 개발 방법)

  • Kang, Junggoo;Kang, Jaemo;Parh, Junhwan;Mun, Duhwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.33-40
    • /
    • 2021
  • The deterioration of underground facilities, disturbance of the ground due to underground development activities, and changes in ground water can cause ground subsidence accidents in the urban areas. The investigation on the geotechnical and hydraulic factors affecting the ground subsidence accident is very significant to predict the ground subsidence risk in advance. In this study, an analysis DB was constructed through 3D ground modeling to utilize the currently operating geotechnical survey information DB and ground water behavior information for risk prediction. Additionally, using these results, the relationship between the actual ground subsidence occurrence history and ground conditions and ground water level changes was confirmed. Furthermore, the methodology used to visualize the risk of ground subsidence was presented by reconstructing the engineering characteristics of the soil presented according to the Unified Soil Classification System (USCS) in the existing geotechnical survey information into the internal erosion sensitivity of the soil, Based on the result, it was confirmed that the ground in the area where the ground subsidence occurred consists of more than 40% of sand (SM, SC, SP, SW) vulnerable to internal erosion. In addition, the effect of the occurrence frequency of ground subsidence due to the change in ground water level is also confirmed.

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Hydrograph Separation and Flow Characteristic Analysis for Observed Rainfall Events during Flood Season in a Forested Headwater Stream (산지계류에 있어서 홍수기의 강우사상에 대한 유출수문곡선 분리 및 특성 분석)

  • Nam, Sooyoun;Chun, Kun-Woo;Lee, Jae Uk;Kang, Won Seok;Jang, Su-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.1
    • /
    • pp.49-60
    • /
    • 2021
  • We examined the flow characteristics by direct runoff and base flow in a headwater stream during observed 59 rainfall events of flood season (June~September) from 2017 to 2020 yrs. Total precipitation ranged from 5.0 to 400.8 mm, total runoff ranged from 0.1 to 176.5 mm, and runoff ratio ranged from 0.1 to 242.9% during the rainfall events. From hydrograph separation, flow duration in base flow (139.3 days) was tended to be longer than direct runoff (78.3 days), while the contribution of direct runoff in total runoff (54.2%) was greater than base flow (45.8%). The total amount and peak flow of direct runoff and base flow had the highest correlation (p<0.05) with total precipitation and duration of rain among rainfall and soil moisture conditions. Dominant rainfall events for the total amount and peak flow of base flow were generated under 5.0~200.4 and 10.5~110.5 mm in total precipitation. However, when direct runoff occurred as dominant rainfall events, total amount and peak flow were increased by 267.4~400.8 and 169.0~400.8 mm in total precipitation. Therefore, the unique aspects of our study design permitted us to draw inferences about flow characteristic analysis with the contribution of base flow and/or direct runoff in the total runoff in a headwater stream. Furthermore, it will be useful for the long-term strategy of effective water management for integrated surface-groundwater in the forested headwater stream.